Contact Us Toll Free
Buy
batteries on-line

Request Info
UPS Systems
Batteries
Emergency Lighting
Battery
Chargers
Battery Storage
Specials!
Service
Lease Info
| |

Powerware 9305 UPS


 | Uninterruptible
power protection against power failures, power sags, power surges,
brownouts, line noise, high voltage spikes, frequency variation, ups,
switching transients and harmonic distortion |
 | Advanced Battery
Management (ABM™) - doubles battery service
life |
 | LanSafe III
compatible - an easy and complete power management solution |
 | Silent - Ideal for
server rooms |
 | DC Expert™ -
accurate remaining back-up time indication
|
|
 |
25 - 45 kVA
 | Double Conversion
Topology ensures trouble-free output. |
 | 3-Phase UPS with
3-Phase Bypass ensures balanced loading of the mains also in bypass.
|
 | Widest Input
Voltage and Frequency Window in the Market means longer battery life and
increased reliability. |
 | Continuous 100%
Unbalanced Loading means that loads can be started and stopped without
worrying about balancing. |
 | On-site Upgrading
Possible means that the customer can later increase the load without
buying a new UPS. |
 | Onput Power Factor
of 0.96 means smaller fuses are used, ensuring a more cost effective
installation. |
 | Selectable Output
Voltage ensures excellent output voltage properties for demanding
situations |
 | Communication
Interfaces allow serial communication with local computers and remote
computers via modem. The relay interface allows building monitoring.
|
 | LanSafe III
Compatibility for an easy and complete power management solution.
|
 | Sentinel FORS
Compatibility for remote monitoring by service centers. |
 | PowerVision®
Compatibility for top of the line monitoring and trend analysis software
for monitoring all components from UPSs and generators to utility and power
distribution (the whole power train). |
 | Programmable
Building Alarms gives flexibility in meeting site/application specific
demands. |
 | Advanced Battery
Management (ABM™). Since the UPS charges the batteries only
when necessary, the temperature of the batteries is lower and corrosion is
lessened, allowing a 50% longer life time for the batteries. On-line remote
monitoring during rest mode, safe test means that the UPS doesn't switch to
battery mode and the load will not crash in case of faulty battery. Test
results and Advanced Battery Management™ status availibility via local and
remote monitoring ensures early warning for the customer and the service. In
case of faulty battery, the early warning gives enough time for the customer
to change the battery bank before it becomes useless |
 | DC Expert™
"learns" the battery and takes aging into account, ensuring an accurate
remaining back-up time indication. |
 | Size. The unit
is small, light, equipped with castors and has a very small foot print making
it ideal for a server room. It is easy to move and install. |
 | Robust Design
makes this UPS ideal for industrial environments. |
 | Front Access
for installation and service |
 | Ease of Use.
LEDs indicate the status of the UPS and there is one-switch operation.
|
 | Battery Start
means that it can be started also when the mains is missing. |
 | Silent makes
this USP ideal for server rooms |
7.5 - 15 kVA
 | Double Conversion
Topology ensures trouble free output. |
 | 3-Phase UPS with
3-Phase Bypass ensures balanced loading of the mains also in bypass.
|
 | Widest Input
Voltage and Frequency Window in the Market means longer battery life and
increased reliability. |
 | Continuous 100%
Unbalanced Loading means that loads can be started and stopped without
worrying about balancing. |
 | On-site Upgrading
Possible means that the customer can later increase the load without
buying a new UPS. |
 | Onput Power Factor
of 0.96 means smaller fuses are used, ensuring a more cost effective
installation. |
 | Selectable Output
Voltage ensures excellent output voltage properties for demanding
situations. |
 | Communication
Interfaces allow serial communication with local computers and remote
computers via modem. The relay interface allows building monitoring.
|
 | LanSafe III
Compatibility for an easy and complete power management solution.
|
 | Sentinel FORS
Compatibility for remote monitoring by service centers. |
 | PowerVision®
Compatibility for top of the line monitoring and trend analysis software
for monitoring all components from UPSs and generators to utility and power
distribution (the whole power train). |
 | Advanced Battery
Management (ABM™). Since the UPS charges the batteries only
when necessary, the temperature of the batteries is lower and corrosion is
lessened, allowing a 50% longer life time for the batteries. On-line remote
monitoring during rest mode, safe test means that the UPS doesn't switch to
battery mode and the load will not crash in case of faulty battery. Test
results and Advanced Battery Management™ status availibility via local and
remote monitoring ensures early warning for the customer and the service. In
case of faulty battery, the early warning gives enough time for the customer
to change the battery bank before it becomes useless. |
 | DC Expert™
"learns" the battery and takes aging into account, ensuring an accurate
remining back-up time indication. |
 | Size. The unit
is small, light, equipped with castors and has a very small foot print making
it ideal for a server room. It is easy to move and install. |
 | Robust Design
makes this UPS ideal for industrial environments. |
 | Ease of Use.
LEDs indicate the status of the UPS and there is one-switch operation.
|
 | Battery Start
means that it can be started also when the mains is missing. |
 | Silent makes
this UPS ideal for server rooms. |



7.5 - 15 kVA
Specifications
|
Input |
|
Input for
rectifier |
380/220V: 400/230V
or 415/240V |
|
Input for bypass |
380/220V: 400/230V
or 415/240V |
|
Voltage range |
294/170V -
478/276V |
|
Frequency |
50/60 Hz |
|
Power Factor |
0.96 |
|
Efficiency |
94% (online)
99% (Efficiency Optimiser™) |
|
Output |
|
Voltage |
380/220V: 400/230V
or 415/240V ±1% field selectable |
|
Frequency |
50/60 Hz ±0.5 ±1.0
or ±2.0 Hz selectable synchronized to mains
±0.005 Hz free running, slew rate 1Hz/sec. |
|
Dynamic response |
±5% at 100% load
change response time 1ms to steady state |
|
Voltage disortion |
<2% THD on linear
load
<5% THD on nonlinear load |
|
Overload capacity |
150% 30 sec. on
inverter |
|
Battery |
|
Type |
Sealed lead-acid
batteries |
|
Back-up time |
typical 7-18 min
at full load |
|
Recharge time |
<5 hr up to 90%
capacity |
|
Battery management |
ABM™
Technology (Advanced Battery Management™) |
|
Battery Test |
DC Expert™ |
|
Control Features |
|
User interface |
Monitoring panel
with LEDs: UPS on, Line on, Battery operation
Bypassed, Overload, Over temperature, Service required
Load bar and Audible alarm |
|
Remote interface |
2 pcs RS232 ports
- one with modem interface
Voltage free relays: Line failure, Low battery, Bypass and Alarm
Emergency power off - input, Building alarm signal - inputs |
|
Environmental |
|
Temperature |
0-40°C,
recommended 15-25°C |
|
Humidity |
5-90% RH
non-condensing |
|
Ventilation |
Fan cooling,
temperature µP monitored |
|
Audible noise |
<50dB(A) at 1
metre |
|
Safety |
EN50091-1 |
|
EMC |
EN50091-2 (IEC801) |
|
Protection class |
IP20S |
|
|
|
Weight (kg) |
PWPM7.5 175/215*
PWPM10 175/215* PWPM15 215 |
|
Dimensions WxDxH
(mm) |
400x750x700 |
|
Software |
|
|
-LanSafe III with
Cross Platform shutdown
-PowerVision monitoring compatible
-PowerCare®
-Sentinel - FORS
(Full Online Remote Service) compatible |
|
Options |
|
|
-External Battery
Cabinets
-10 year batteries
-Remote Status Panel
-Isolation transformer
-LanQuattro
-Alarm Extension Unit
-ConnectUPS SNMP adapter
-External LCD Panel |
Battery Run Times
With various computer loads Powerware Prime 7.5 - 15 kVA models. Standard
batteries 48 pcs in series
|
Load |
|
config |
1
kVA |
2 kVA |
3 kVA |
4 kVA |
5 kVA |
6 kVA |
7 kVA |
7.5 kVA |
8 kVA |
9 kVA |
10 kVA |
11 kVA |
12 kVA |
14 kVA |
15 kVA |
|
UPS |
170 min |
85 min |
55 min |
40 min |
30 min |
24 min |
20 min |
18 min |
17 min |
15 min |
13 min |
11 min |
10 min |
8 min |
7
min |
|
UPS + BAT-A |
7h |
3,5h |
130 min |
95 min |
72 min |
60 min |
50 min |
44 min |
40 min |
35 min |
30 min |
28 min |
25 min |
20 min |
18 min |
|
UPS + BAT-B |
11h |
6h |
3,5h |
160 min |
125 min |
100 min |
82 min |
74 min |
70 min |
60 min |
50 min |
46 min |
40 min |
35 min |
30 min |
|
UPS + BAT-A +
BAT-B |
17h |
8,5h |
5,5h |
4h |
180 min |
140 min |
120 min |
107 min |
100 min |
88 min |
75 min |
68 min |
60 min |
50 min |
45 min |
|
UPS + 2 * BAT-B |
22h |
11h |
7h |
5h |
4h |
180 min |
150 min |
142 min |
135 min |
120 min |
100 min |
90 min |
80 min |
65 min |
60 min |
|
UPS + 2 * BAT-B +
BAT-A |
28h |
14h |
9h |
6,5h |
5h |
4h |
200 min |
180 min |
170 min |
145 min |
130 min |
110 min |
100 min |
80 min |
75 min |
|
UPS + 3 * BAT-B |
35h |
17h |
11h |
8h |
6h |
5h |
4h |
220 min |
210 min |
180 min |
160 min |
140 min |
120 min |
100 min |
90 min |
NOTE:
The UPS includes internal battery |



25
- 45 kVA
Specifications
|
Input |
|
Input for
rectifier |
380/220V: 400/230V
or 415/240V |
|
Input for bypass |
380/220V: 400/230V
or 415/240V |
|
Voltage range |
294/170V -
478/276V |
|
Frequency |
50/60 Hz |
|
Power Factor |
0.96 |
|
Efficiency |
94% (online)
99% (Efficiency Optimiser™) |
|
Output |
|
Voltage |
380/220V: 400/230V
or 415/240V ±1% field selectable |
|
Frequency |
50/60 Hz ±0.5 ±1.0
or ±2.0 Hz selectable synchronized to mains
±0.005 Hz free running, slew rate 1Hz/sec. |
|
Dynamic response |
±5% at 100% load
change response time 1ms to steady state |
|
Voltage disortion |
<2% THD on linear
load
<5% THD on nonlinear load |
|
Overload capacity |
150% 30 sec. on
inverter |
|
Battery |
|
Type |
Sealed lead-acid
batteries |
|
Back-up time |
typical 10-20 min
at full load |
|
Recharge time |
<5 hr up to 90%
capacity |
|
Battery management |
ABM™
Technology (Advanced Battery Management™) |
|
Battery Test |
DC Expert™ |
|
Control Features |
|
User interface |
Monitoring panel
with LCD display: LED's: UPS on, Line on, Battery operation
Bypassed, and Audible alarm |
|
Remote interface |
2 pcs RS232 ports
- one with modem interface
Voltage free relays: Line failure, Low battery, Bypass and Alarm
Emergency power off - input, Building alarm signal - inputs |
|
Environmental |
|
Temperature |
0-40°C,
recommended 15-25°C |
|
Humidity |
5-90% RH
non-condensing |
|
Ventilation |
Fan cooling,
temperature µP monitored |
|
Audible noise |
<50dB(A) at 1
metre |
|
Safety |
EN50091-1 |
|
EMC |
EN50091-2 (IEC801) |
|
Protection class |
IP21 |
|
|
|
Weight (kg) |
215 |
|
Dimensions WxDxH
(mm) |
382x775x1530 |
|
Software |
|
|
-LanSafe III with
Cross Platform shutdown
-PowerVision monitoring compatible
-PowerCare®
-Sentinel - FORS
(Full Online Remote Service) compatible |
|
Options |
|
|
-External Battery
Cabinets
-10 year batteries
-Remote Status Panel
-Isolation transformer
-input filter for <10% THD
-LanQuattro
-Alarm Extension Unit
-ConnectUPS SNMP adapter
-External LCD Panel |
Battery Run Times
Standard batteries 48 pcs in series
|
LOAD |
|
config |
5
kVA |
10
kVA |
15
kVA |
20
kVA |
25
kVA |
30
kVA |
35
kVA |
40
kVA |
45
kVA |
|
UPS + BAT-D |
120 min |
58
min |
36
min |
25
min |
20
min |
15
min |
12
min |
10
min |
9
min |
|
UPS + BAT-E |
220 min |
105 min |
65
min |
45
min |
35
min |
28
min |
22
min |
19
min |
16
min |
|
UPS + BAT F |
7h |
3.5h |
130
min |
90
min |
70
min |
55
min |
45
min |
40
min |
35
min |
|
UPS + 2 * BAT-E |
9h |
4h |
155 min |
110
min |
85
min |
65
min |
55
min |
45
min |
40
min |
|
UPS + 3 * BAT-E |
15h |
7h |
4.5h |
185
min |
140
min |
110
min |
95
min |
80
min |
65
min |
|
UPS + 2 * BAT-F |
18h |
8h |
5.5h |
220 min |
165 min |
135 min |
110 min |
90
min |
80
min |
|
Powerware 9305 Powerware 9305
Powerware 9305 Powerware 9305 Powerware 9305 Powerware 9305
Powerware 9305 Powerware 9305 Powerware 9305 Powerware 9305
Powerware 9305 Powerware 9305 Powerware 9305 Powerware 9305
Powerware 9305 Powerware 9305 Powerware 9305 Powerware 9305
Powerware 9305 Powerware 9305 Powerware 9305 Powerware 9305
Powerware 9305 Powerware 9305 Powerware 9305 Powerware 9305
Powerware 9305 Powerware 9305 Powerware 9305 Powerware 9305
Powerware 9305 Powerware 9305 Powerware 9305 Powerware 9305
Powerware 9305 Powerware 9305 Powerware 9305 Powerware 9305
Powerware 9305 Powerware 9305 Powerware 9305 Powerware 9305
Powerware 9305
PW3105 PW3110 PW5110 PW5115 Tower PW5115 Rack PW5119 PW5125 Tower PW5125 Rack/Tower PW5140 Prestige PW9104 PW9120 PW9125 PW9140 PW9150 PW9155 PW9170 PW9170+ Ferrups Plus 18 Plus 36 PW9305 PW9330 PW9390 PW9315 BladeUPS PW9355
PW3105 PW3110 PW5110 PW5115 Tower PW5115 Rack PW5119 PW5125 Tower PW5125 Rack/Tower PW5140 Prestige PW9104 PW9120 PW9125 PW9140 PW9150 PW9155 PW9170 PW9170+ Ferrups Plus 18 Plus 36 PW9305 PW9330 PW9390 PW9315 BladeUPS PW9355
PW3105 PW3110 PW5110 PW5115 Tower PW5115 Rack PW5119 PW5125 Tower PW5125 Rack/Tower PW5140 Prestige PW9104 PW9120 PW9125 PW9140 PW9150 PW9155 PW9170 PW9170+ Ferrups Plus 18 Plus 36 PW9305 PW9330 PW9390 PW9315 BladeUPS PW9355
|