Power Factor Inc. will insure the Powerware PW9120-Batt-2000 P/N
05147369-5502 UPS is the right product for your application.

Powerware 9120-BATT-2000 PW9120-BATT-2000 PW9120BATT2000 UPS


 | True double
conversion online technology gives you protection from all nine power
problems |
 | Simple
installation and operation |
 | Intuitive LCD
screen provides real-time updates of UPS status, power usage, battery run
time remaining and other critical UPS parameters |
 | Hot-swappable
batteries |
 | Extended run time
capability with external battery modules |
 | User-selectable
High Efficiency Mode |
 | Complete offering
of power management software included to ensure data integrity |
 | Triple power
warranty (US and Canada)
 | 10-year
pro-rated warranty (2 years inclusive) |
 | 60-day money
back guarantee |
 | $25,000 load
protection guarantee |
|
|
Rating: |
700 VA - 3000 VA |
|
Voltage: |
120 and 230 Vac |
|
Frequency: |
50/60 Hz
(auto-sensing) |
|
Configuration: |
Tower |

As businesses become
increasingly dependent on technology for their fundamental operation, the
need for system availability is of paramount importance. The Powerware 9120
UPS is designed for those applications that need maximum protection in the
700 VA - 3kVA range. With its high-frequency, double-conversion online
topology, providing nonstop clean sine wave power, advanced communications
and space-saving tower design, the Powerware 9120 is the ideal solution for
networks, web servers, telecommunications applications and other critical
electronic equipment.
In addition to its proven design, the Powerware 9120 offers Advanced Battery
Management® (ABM) and sophisticated communications to provide
maximum system availability. ABM uses a three-stage charging technique that
not only doubles battery service life, but optimizes battery charge time and
provides 60-day notification of the end of useful life for the batteries.
The Powerware 9120's communications are flexible, allowing for local,
network or remote monitoring and management. The Powerware 9120 includes the
latest version of Powerware's Software Suite, which provides power
monitoring and shutdown software.
Simple plug-and-play operation makes installing the Powerware 9120 fast and
easy. A single button touch provides clean, uninterruptible power to the
critical load. An intuitive LCD screen provides real-time updates of UPS
status, power usage, battery run time remaining, and other critical UPS
parameters.
With the Powerware 9120, Powerware delivers a best-in-class power solution
for maximum system availability, and peace of mind.
|


|



Low voltage
details
|
Electrical Input |
|
Nominal
Voltage |
For
user-selectable voltages see Model
Selection Guide |
|
Input Voltage
Range |
80-144 Vac |
|
Input Power
Factor |
>.95% |
|
Operating
Frequency |
50/60 Hz,
Auto-sensing |
|
Frequency
Range |
45 - 65 Hz |
|
Input
Protection |
Fuse or
circuit breaker |
|
Electrical Output |
|
On Utility
Voltage Regulation |
+/-2% of
nominal |
|
On Battery
Voltage Regulation |
+/-3% of
nominal |
|
Nominal Output
Voltage |
Same as
selected input voltage |
|
Output Voltage
Waveform |
Sine Wave |
|
Output Voltage
Distortion |
<3%THD |
|
Output
protection |
Electronic
overload sensing,and circuit breaker protection |
|
Efficiency |
Online
Mode:>86%;
Hi-Efficiency Mode:>90% |
|
Battery |
|
Internal
Battery type |
Sealed,
lead-acid; maintenance free |
|
EBM Battery
Type |
Sealed,
lead-acid; maintenance free |
|
On Battery
Runtime |
See Battery Runtimes |
|
Battery
Replacement |
Hot-swappable
internal and external batteries |
|
Recharge Time |
<4 hours to
90%capacity |
|
Start-On-Battery |
Allows start
of UPS without utility input |
|
Communications |
|
User Interface |
LCD status
screen |
|
Audible Alarms |
UPS alarm
conditions,including:
On-Battery,Low Battery,Overload, UPS Fault |
|
Network
transient Protector |
In and out
jack for all models.
UL497A tested |
|
REPO Port |
Meets NEC code
645-11 intent and UL requirements |
|
Communications |
One RS232
Serial Port;One Communications Slot; One USB Port |
|
Communications
cable |
6-foot
communications cable included |
|
Power
Management Software |
Powerware
Software Suite CD, free updates on www.powerware.com |
|
General |
|
Topology |
True online,
double-conversion |
|
Diagnostics |
Full system
self-test on power up |
|
UPS Bypass |
Automatic on
Overload or UPS failure <4ms |
|
Transfer Time
to battery |
0 ms |
|
Dimensions and
Weights |
See
Model Selection Guide |
|
Overload
Capacity |
125% for 10
minutes before transfer to bypass;
150% for 10 seconds before transfer to bypass |
|
Environmental and Safety |
|
Safety
Certifications |
UL1778;cUL22.2
NO.107.1 |
|
EMI Compliance |
FCC Part 15,
Class B (700-1500), Class A (2000-3000) 230V,
EN 50091-2 Class B (700-1500), Class A (2000-3000) |
|
Operating
Temperature |
0 to 40 C (32
to 104 F) |
|
Storage
Temperature |
-15 to 50 C (5
to 122 F) |
|
Storage
Temperature |
0o
to 25o C (32o to 77o F) |
|
Relative
Humidity |
0%to
95%non-condensing |
|
Immunity |
EEE C62.41,
IEC 61000-4 -2, -3, -4, -5 |
|
Network
Transient Protector |
UL497A |
|
Audible Noise
at 1 meter |
700-1000VA:
<45dB;1500VA <50dB; 2000-3000 <52dB |
|
Altitude |
3000m (10,000
ft) without deteriorating |
Note: Due to
continuing product improvement programs, specifications are
subject to change without notice.
|
Model Selection Guide
Model
Number |
Power Out
(VA/Watt) |
Input/Output
Voltage (Vac) |
Frequency
(Hz)2 |
Input
Connection3 |
Output
Receptacles4 |
Dimensions
(HxWxD)
in/mm |
Weight
(lb/kg) |
|
120 Vac Models1 |
|
PW9120 700 |
700/490 |
120 |
50/60 |
5-15P |
(4) 5-15R |
9.6 x 6.2 x
16.2/
243 x 158 x 412 |
29/13.2 |
|
PW9120 1000 |
1000/700 |
120 |
50/60 |
5-15P |
(4) 5-15R,
(2) 5-20R |
9.6 x 6.2 x
16.2/
243 x 158 x 412 |
35.5/16.1 |
|
PW9120 1500 |
1500/1050 |
120 |
50/60 |
5-15P |
(4) 5-15R,
(2) 5-20R |
10.8 x 6.7 x
17.5/
275 x 170 x 444 |
46.5/21.1 |
|
PW9120 2000 |
2000/1400 |
120 |
50/60 |
5-20P |
(6) 5-20R |
14.2 x 8.6 x
18.6/
361 x 217 x 472 |
82/37.2 |
|
PW9120 3000 |
3000/2100 |
120 |
50/60 |
L5-30P |
(4) 5-15R,
(2) 5-20R
(1) L5-30R |
14.2 x 8.6 x
18.6/
361 x 271 x x 472 |
89/40.5 |
|
208 Vac Models |
|
PW9120 3000 |
3000/2100 |
208 |
50/60 |
L6-20P |
(2)L6-15R,
(1)L6-20R,
(1)L6-30R |
14.2 x 8.6 x
18.6/
361 x 217 x 472 |
89/40.5 |
|
230 Vac Models5 |
|
PW9120 700i |
700/490 |
230 |
50/60 |
IEC-C14 |
(4)IEC-C13 |
9.6 x 6.2 x
16.2/
243 x 158 x 412 |
28/12.6 |
|
PW9120 1000i |
1000/700 |
230 |
50/60 |
IEC-C14 |
(4)IEC-C13 |
9.6 x 6.2 x
16.2/
243 x 158 x 412 |
34/15.3 |
|
PW9120 1500i |
1500/1050 |
230 |
50/60 |
IEC-C14 |
(4)IEC-C13 |
10.8 x 6.7 x
17.5/
275 x 170 x 444 |
44/19.8 |
|
PW9120 2000i |
2000/1400 |
230 |
50/60 |
IEC-C14 |
((4)IEC-C13,
(1)IEC-C19 |
14.2 x 8.6 x
18.6/
361 x 217 x 472 |
81.6/37 |
|
PW9120 3000i |
3000/2100 |
230 |
50/60 |
IEC-C20 |
(4)IEC-C13,
(1)IEC-C19 |
14.2 x 8.6 x
18.6/
361 x 217 x 472 |
85/38.5 |
|
Optional Extended Battery Modules (EBMs) |
|
PW9120 BATT 700 |
- |
- |
- |
Standard
Connector |
- |
9.6 x 6.2 x
16.2/
243 x 158 x 412 |
31/14 |
|
PW9120 BATT 1000 |
- |
- |
- |
Standard
Connector |
- |
9.6 x 6.2 x
16.2/
243 x 158 x 412 |
44/20 |
|
PW9120 BATT 1500 |
- |
- |
- |
Standard
Connector |
- |
10.8 x 6.7 x
17.5/
275 x 170 x 444 |
57/26 |
|
PW9120 BATT 2000 |
- |
- |
- |
Standard
Connector |
- |
14.2 x 8.6 x
18.6/
361 x 217 x 472
|
110/50 |
|
PW9120 BATT 3000 |
- |
- |
- |
Standard
Connector |
- |
14.2 x 8.6 x
18.6/
361 x 217 x 472
|
110/50 |
1
Also user-selectable for 100, 110, and 127 Vac.
2 Automatic frequency selection.
3 120V models have 6-ft. attached line cord. 230V models
have 6-ft. detachable line cord.
4 Divided into 2 Load Segments (receptacle groups).
5 Also user-selectable for 220 and 240 Vac |
Available Options
|
Order Number |
Description |
|
IPK-0329 |
ConnectUPS-BD
SNMP/WEB Card |
|
1014018 |
AS/400 Relay Card |
Battery Run
Times (in minutes full load/half load))
|
VA |
Standard
Internal
Battery |
1 EBM |
2 EBMs |
3 EBMs |
4 EBMs |
5 EBMs |
|
700 |
7/18 |
34/70 |
64/140 |
- |
- |
- |
|
1000 |
7/18 |
36/80 |
66/155 |
- |
- |
- |
|
1500 |
7/18 |
29/67 |
56/130 |
- |
- |
- |
|
2000 |
12/34 |
49/107 |
93/195 |
140/310 |
192/403 |
240/504 |
|
3000 |
6/15 |
30/70 |
57/128 |
87/191 |
120/264 |
148/325 |
Up
to 2 EBMs can be connected to 700/1000/1500VA models and up to 5 EBMs
can be connected to 2000/3000VA models.Run time chart provides typical
information.Run times are approximate and may vary with
equipment,configuration,battery age,temperature,etc. |
|



High voltage
details
|
Electrical Input |
|
Nominal
Voltage |
For
user-selectable voltages see Model
Selection Guide |
|
Input Voltage
Range |
120/140/160-276 Vac |
|
Input Power
Factor |
>.95% |
|
Operating
Frequency |
50/60 Hz,
Auto-sensing |
|
Frequency
Range |
45 - 65 Hz |
|
Input
Protection |
Fuse or
circuit breaker |
|
Electrical Output |
|
On Utility
Voltage Regulation |
+/-2% of
nominal |
|
On Battery
Voltage Regulation |
+/-3% of
nominal |
|
Nominal Output
Voltage |
Same as
selected input voltage |
|
Output Voltage
Waveform |
Sine Wave |
|
Output Voltage
Distortion |
<3%THD |
|
Output
protection |
Electronic
overload sensing,and circuit breaker protection |
|
Efficiency |
Online
Mode:>86%;
Hi-Efficiency Mode:>90% |
|
Battery |
|
Internal
Battery type |
Sealed,
lead-acid; maintenance free |
|
EBM Battery
Type |
Sealed,
lead-acid; maintenance free |
|
On Battery
Runtime |
See Battery Runtimes |
|
Battery
Replacement |
Hot-swappable
internal and external batteries |
|
Recharge Time |
<4 hours to
90%capacity |
|
Start-On-Battery |
Allows start
of UPS without utility input |
|
Communications |
|
User Interface |
LCD status
screen |
|
Audible Alarms |
UPS alarm
conditions,including:
On-Battery,Low Battery,Overload, UPS Fault |
|
Network
transient Protector |
In and out
jack for all models.
UL497A tested |
|
REPO Port |
Meets NEC code
645-11 intent and UL requirements |
|
Communications |
One RS232
Serial Port;One Communications Slot; One USB Port |
|
Communications
cable |
6-foot
communications cable included |
|
Power
Management Software |
Powerware
Software Suite CD, free updates on www.powerware.com |
|
General |
|
Topology |
True online,
double-conversion |
|
Diagnostics |
Full system
self-test on power up |
|
UPS Bypass |
Automatic on
Overload or UPS failure <4ms |
|
Transfer Time
to battery |
0 ms |
|
Dimensions and
Weights |
See
Model Selection Guide |
|
Overload
Capacity |
125% for 10
minutes before transfer to bypass;
150% for 10 seconds before transfer to bypass |
|
Environmental and Safety |
|
Safety
Certifications |
CE marked,EN
50091-1-1 and IEC 60950 |
|
EMI Compliance |
FCC Part 15,
Class B (700-1500), Class A (2000-3000) 230V,
EN 50091-2 Class B (700-1500), Class A (2000-3000) |
|
Operating
Temperature |
0 to 40 C (32
to 104 F) |
|
Storage
Temperature |
-15 to 50 C (5
to 122 F) |
|
Storage
Temperature |
0o
to 25o C (32o to 77o F) |
|
Relative
Humidity |
0%to
95%non-condensing |
|
Immunity |
EEE C62.41,
IEC 61000-4 -2, -3, -4, -5 |
|
Network
Transient Protector |
UL497A |
|
Audible Noise
at 1 meter |
700-1000VA:
<45dB;1500VA <50dB; 2000-3000 <52dB |
|
Altitude |
3000m (10,000
ft) without deteriorating |
Note: Due to
continuing product improvement programs, specifications are
subject to change without notice.
|
Model Selection Guide
Model
Number |
Power Out
(VA/Watt) |
Input/Output
Voltage (Vac) |
Frequency
(Hz)2 |
Input
Connection3 |
Output
Receptacles4 |
Dimensions
(HxWxD)
in/mm |
Weight
(lb/kg) |
|
120 Vac Models1 |
|
PW9120 700 |
700/490 |
120 |
50/60 |
5-15P |
(4) 5-15R |
9.6 x 6.2 x
16.2/
243 x 158 x 412 |
29/13.2 |
|
PW9120 1000 |
1000/700 |
120 |
50/60 |
5-15P |
(4) 5-15R,
(2) 5-20R |
9.6 x 6.2 x
16.2/
243 x 158 x 412 |
35.5/16.1 |
|
PW9120 1500 |
1500/1050 |
120 |
50/60 |
5-15P |
(4) 5-15R,
(2) 5-20R |
10.8 x 6.7 x
17.5/
275 x 170 x 444 |
46.5/21.1 |
|
PW9120 2000 |
2000/1400 |
120 |
50/60 |
5-20P |
(6) 5-20R |
14.2 x 8.6 x
18.6/
361 x 217 x 472 |
82/37.2 |
|
PW9120 3000 |
3000/2100 |
120 |
50/60 |
L5-30P |
(4) 5-15R,
(2) 5-20R
(1) L5-30R |
14.2 x 8.6 x
18.6/
361 x 271 x x 472 |
89/40.5 |
|
208 Vac Models |
|
PW9120 3000 |
3000/2100 |
208 |
50/60 |
L6-20P |
(2)L6-15R,
(1)L6-20R,
(1)L6-30R |
14.2 x 8.6 x
18.6/
361 x 217 x 472 |
89/40.5 |
|
230 Vac Models5 |
|
PW9120 700i |
700/490 |
230 |
50/60 |
IEC-C14 |
(4)IEC-C13 |
9.6 x 6.2 x
16.2/
243 x 158 x 412 |
28/12.6 |
|
PW9120 1000i |
1000/700 |
230 |
50/60 |
IEC-C14 |
(4)IEC-C13 |
9.6 x 6.2 x
16.2/
243 x 158 x 412 |
34/15.3 |
|
PW9120 1500i |
1500/1050 |
230 |
50/60 |
IEC-C14 |
(4)IEC-C13 |
10.8 x 6.7 x
17.5/
275 x 170 x 444 |
44/19.8 |
|
PW9120 2000i |
2000/1400 |
230 |
50/60 |
IEC-C14 |
((4)IEC-C13,
(1)IEC-C19 |
14.2 x 8.6 x
18.6/
361 x 217 x 472 |
81.6/37 |
|
PW9120 3000i |
3000/2100 |
230 |
50/60 |
IEC-C20 |
(4)IEC-C13,
(1)IEC-C19 |
14.2 x 8.6 x
18.6/
361 x 217 x 472 |
85/38.5 |
|
Optional Extended Battery Modules (EBMs) |
|
PW9120 BATT 700 |
- |
- |
- |
| | | |