Batteries UPS Technology Emergency Lighting Battery Chargers TVSS 9 Power Problems Olight Flashlights Problems with Power Factory Links Contact Us
Powerware Manuals Eaton 3S PW3105 PW3110 PW5110 PW5115 Tower PW5115 Rack Evolution Evolution S PW5119 PW5125 Tower PW5125 Rack/Tower PW5130 PW5140 PW9104 PW9120 PW9125 EX Tower EX Rack/Tower PW9130 Tower PW9130 Rack PW9135 PW9140 PW9150 PW9155 PW9170 PW9170+ Prestige Ferrups BladeUPS PW9305 PW9315 PW9330 PW9355 PW9390 Plus 18 Plus 36 Eaton 9E 3 Phase UPS IPK-0329
800-706-7009
A+ Rating with the Better Business Bureau
| |
• Powerware Manuals • Eaton 3S • PW3105 • PW3110 • PW5110 • PW5115 Tower • PW5115 Rack • Evolution • Evolution S • PW5119 • PW5125 Tower • PW5125 Rack/Tower • PW5130 • PW5140 • PW9104 • PW9120 • PW9125 • EX Tower • EX Rack/Tower • PW9130 Tower • PW9130 Rack • PW9135 • PW9140 • PW9150 • PW9155 • PW9170 • PW9170+ • Prestige • Ferrups • BladeUPS • PW9305 • PW9315 • PW9330 • PW9355 • PW9390 • Plus 18 • Plus 36 • Eaton 9E 3 Phase UPS • IPK-0329 •

Eaton Powerware 9104 UPS
Contact us @
800-706-7009 or click here for more information.


- Uninterruptible
power protection against power failures, power sags, power surges,
brownouts, line noise, high voltage spikes, frequency variation, switching
transients and harmonic distortion
- Advanced Battery
Management (ABM™) - doubles battery service life
- Bundled with power
management software - ensures data integrity
- Standard Automatic
Bypass Switch - prevents your equipment from crashing
- Advanced Power
Isolation - for clean output voltage
|
Rating: |
3.1 - 6 kVA |
|
Voltage: |
High and low voltage
models available (see brochure for details) |
|
Frequency: |
50/60 Hz |
|
Configuration: |
Internal batteries;
External extended battery pack available |
|
Topology: |
Dual Conversion
Online |
|
 |

- Rating: Double
Conversion Online Technology provides reliable operation
-
Advanced Battery Management (ABM™) doubles battery service life
- Standard Automatic
Bypass Switch - prevents equipment from crashing
- Bundled with LanSafe
III/FailSafe III
power
management software to ensure data integrity
- Advanced Power
Isolation for clean output voltage
- Expandable Power
Levels for future system expansion
- Wide selection of
system enhancing options
- Engine generator
compatible to ensure data integrity
System enhancing
options
- Extended
Battery Packs housed in separate, matching cabinets provide extended
backup time. Up to three battery cabinets may be daisy-chained with easy "plug
and play" connections for more extended time. Battery packs for the rack-mount
models, like the main UPS units, fit in standard 19-inch equipment racks. To
provide maximum flexibility, batteries for the international RSi models come
in separate battery packs.
- Second RS-232
Interface on rear panel allows UPS to communicate with two different
platforms independently.
- Remote Power
Warning Cable Interface Kits enable the UPS to initiate a shutdown in
the event of a power failure. A 25-foot cable is provided. The interface
accommodates AS/400 as well as other operating system platforms.
-
Start-On-Battery allows startup of the computer network from the UPS
battery in the event of AC line failure.
- Remote
Distribution Receptacle Box is available with individually protected
circuits and an eight-foot line cord that plugs directly into the rear of the
UPS. An LI4-30R receptacle plate must be installed on the UPS to use this
option.
- Rack-Mount
units are available for the North American 3.1 kVA models (RS) and
all international models (RSi). The unit is supplied with mounting brackets
for easy installation into a standard 19-inch electronic equipment rack. The
front panel on the rack configuration is mounted horizontally with all the
controls and functions identical to the standard tower models.
- Maintenance
Bypass Switch (Panel Option) allows input voltage to bypass the UPS
and go directly to the connected equipment if an abnormal condition prevents
the UPS from supporting the load.



|
Power |
| Ratings (RS) |
3.1/5.0/6.0
kVA 5.0 units upgradeable) |
|
Electrical Output |
|
Voltage (RS) |
120 VAC for 3.1
kVA
120/208 or 120/240 VAC for 3.1/5.0/6.0 kVA |
| Voltage
Range |
-27 to +22% |
|
Frequency Range |
45 to 65 Hz
(auto-sensing) |
| Current
distortion |
Sinusoidal
active correction |
|
Power Factor |
.96 (active
correction) |
| Connections
(RS) |
Hardwire to
terminal blocks on rear of unit is standard (line cord/plug options
available) |
|
Electrical Input |
|
Voltage (RS) |
120 VAC for 3.1
kVA
120/208 or 120/240 VAC for 3.1/5.0/6.0 kVA |
| Regulation |
+/-2% |
|
Efficiency (RS) |
92% @ typical
load |
|
Wave Form |
Sinusoidal, <2%
THD; <5% non-linear load |
|
Frequency |
50 or 60 Hz,
selectable sync window of +/-3, 1 or .5 Hz |
|
Crest Factor |
3:1 |
|
Isolation (RS) |
Advanced Power
Isolation |
| Connections
(RS) |
Hardwired,
5-15R duplex receptacles are standard (various receptacle options
available) |
|
Battery |
|
Type (RS) |
Internal
battery; valve regulated, sealed lead-acid type |
| Recharge
Time |
<3 hours to
90% capacity |
|
Backup Time |
10 - 15 minutes
at typical load (standard internal battery pack or an RSi with one
external battery pack) |
Model Selection Guide
Model
Number |
kVA
Rating |
Input
Voltage (VAC) |
Output
Voltage (VAC) |
AC Line Cord
Option (15') |
Recommended
Input Service |
Dimensions
H x W x D (in) |
Weight
(lb/kg) |
|
RS Standard Hardwired Models |
| RST31
(Tower) |
3.1 |
120 |
120 |
L5-30P |
30 A |
16 x 6.8 x
24 |
125/56.9 |
|
RST32 (Tower) |
3.1 |
120/208 or
120/240 |
Same as input |
L14-20P |
20 A |
16 x 6.8 x 24 |
125/56.9 |
| RST52
(Tower) |
5.0 |
120/208 or
120/240 |
Same as
input |
L14-30P |
30 A |
24 x 6.8 x
24 |
180/86 |
|
RST62 (Tower) |
6.0 |
120/208 or
120/240 |
Same as input |
L14-30P |
30 A |
24 x 6.8 x 24 |
180/86 |
| RSR31 (Rack) |
3.1 |
120 |
120 |
L5-30P |
30 A |
6.8 x 19 x
24 |
135/61.2 |
|
RSR32 (Rack) |
3.1 |
120/208 or
120/240 |
Same as input |
L14-20P |
20 A |
6.8 x 19 x 24 |
135/61.2 |
|
All models are 50 and 60 Hz capable and are auto-sensing. |
Battery Run Times (in minutes)
|
3.1 kVA Models |
|
Typical Applications |
Load |
RS
w/Standard Internal Batteries |
RS and one Battery Pack |
|
RISC Workstation |
1000VA |
37 |
135 |
|
Mini Computer |
1500 VA |
22 |
82 |
|
Telecom
equipment |
2100 VA |
14 |
48 |
|
Midrange Systems |
2500 VA** |
10 |
41 |
|
Multiple Servers |
3100 VA ** |
8 |
31 |
5.0 and 6.0kVA Models |
|
Typical Applications |
Load |
RS w/Standard Internal Batteries |
RS & One Battery Pack |
RS & Two Battery Packs |
RS & Three Battery Packs |
|
Telecom
Equipment |
2000 VA |
44 |
100 |
150 |
200 |
|
Multiple Servers |
3000 VA |
25 |
60 |
93 |
126 |
|
Multiple Servers |
4000 VA |
17 |
42 |
67 |
99 |
|
Multiple Servers |
5000 VA |
12 |
28 |
46 |
64 |
|
**Backup times for 3.1 kVA units only. |
|
This guide provides typical application information. Battery
times are approximate and may vary with equipment, configuration,
disk access, battery age, temperature, etc. See the External Battery
Packs table below for more details. |
External Battery Packsa
|
Model Number |
Style |
kVA rating of compatible UPS |
Dimensions
H x W x D (in/cm) |
Weight
(lb/kg) |
| RS3-RP2T |
Tower |
3.1 |
16 x 6.3 x 24
40.6 x 17.2 x 61 |
166/175 |
|
RS6-RP1T |
Tower |
5.0/6.0 |
16 x 6.3 x 24
40.6 x 17.2 x 61 |
166/175 |
| RS3-RP2R |
Rack |
3.1 |
6.8 x 19 x 24
17.2 x 48.3 x 24 |
166/175 |
|
|
• Powerware Manuals • Eaton 3S • PW3105 • PW3110 • PW5110 • PW5115 Tower • PW5115 Rack • Evolution • Evolution S • PW5119 • PW5125 Tower • PW5125 Rack/Tower • PW5130 • PW5140 • PW9104 • PW9120 • PW9125 • EX Tower • EX Rack/Tower • PW9130 Tower • PW9130 Rack • PW9135 • PW9140 • PW9150 • PW9155 • PW9170 • PW9170+ • Prestige • Ferrups • BladeUPS • PW9305 • PW9315 • PW9330 • PW9355 • PW9390 • Plus 18 • Plus 36 • Eaton 9E 3 Phase UPS • IPK-0329 •
|