Batteries Eaton Showcase UPS Technology Emergency Lighting Battery Chargers TVSS 9 Power Problems Olight Flashlights Problems with Power Factory Links Contact Us
PW5119 1000 PW5119 1000 RM PW5119 1500 PW5119 1500 RM PW5119 2000 PW5119 2000 RM PW5119 2400 PW5119 3000 PW5119 3000 RM
800-706-7009
A+ Rating with the Better Business Bureau

| |
• PW5119 1000 • PW5119 1000 RM • PW5119 1500 • PW5119 1500 RM • PW5119 2000 • PW5119 2000 RM • PW5119 2400 • PW5119 3000 • PW5119 3000 RM •

Eaton Powerware 5119-3000 RM PW5119-3000RM PW51193000 RM UPS
Contact us @
800-706-7009 or click here for more information.


- Uninterruptible
power protection against power failures, power sags, power surges,
brownouts and line noise
-
Advanced Battery Management (ABM™) doubles battery service life.
- Buck and Double
Boost voltage regulation - conditions voltage without using battery power
- Rack-mount models
- conserve valuable rack space
- Bundled with power
management software - ensures data integrity
|
Rating: |
1000-3000VA; 400 and
600 VA models also available |
|
Voltage: |
100-127 VAC; 208-240
VAC |
|
Frequency: |
50 and 60 Hz |
|
Configuration: |
Cabinet and
rack-mount |
|
Topology: |
Line-Interactive
(pure sine wave output) |
- Compact rack-mount
models conserve valuable rack space.
Buck and Double Boost voltage regulation conditions voltage without
using battery power.
- LanSafe III/FailSafe
III
power management software ensures data integrity.
- Network Transient
Protector isolates network/telephone wiring.
- Hot-Swappable
Batteries simplify service.
-
Precision Power Control (separate receptacle groups) enables scheduled
shutdowns and maximized run time for critical devices.
- Accurate Battery
Testing. By shutting off the charger, the Powerware 5119 is able to test
the actual condition of the battery.
Rack-mount

The Powerware 5119
Rack-mount packs the same award-winning technology of the cabinet models
into a compact design which fits into standard 19 inch equipment racks. By
limiting the rack height of the UPS, the Powerware 5119 conserves room for
other critical equipment such as servers and disk arrays. 1000 and 1500 VA
models measure on 2U (3.5") high and 2000 - 3000 VA models are an
industry-leading 3U (5.25")
|
 |


Rack Specification
Details
|
Electrical Input |
|
Voltage |
120 and 230
VAC Nominal; see Model Selection Guide
for user selectable voltages |
|
On Line
Voltage Range |
-30%, +20%
for nominal voltages; user selectable extended range of -35%, +20%
(-30%, +15% for 127 and 240 VAC) |
|
Nominal Input
Frequency |
50/60 Hz;
auto-selection (60 Hz only for 120 and 127 VAC) |
|
Frequency
Tolerance |
Nominal +/-3
Hz |
|
Electrical Output |
|
Power Levels |
1000-3000 VA |
|
On Line
Regulation |
-10%, +6%;
within Computer Business Equipment Manufacturers Association's
Guidelines (-15%; +10% using extended range) |
|
On Battery
Regulation |
< +/-5% RMS |
|
Voltage Wave
Shape (on battery) |
Sine wave, 3%
THD |
|
Overload
(Normal Operation) |
Minimum 200%
of full load for 15 cycles |
|
No Load Sleep
Mode (Battery Mode) |
Outputs are
turned off if <5% load is detected (selectable) |
|
Interconnecting Cords ( 230 VAC Models only) |
2 ea. IEC-320
(10 A); PRC3000i-RM also include: 1 ea. IEC-320 (16A) with
stripped male end for rewirable plug |
|
Backup Time |
See Backup
Times table |
|
Battery
Charging |
<3 hrs. to 90%
usable capacity |
|
Battery Type |
Sealed,
maintenance-free lead-acid; starved electrolyte |
|
Start-On-Battery |
Startup with
UPS batteries in absence of utility power |
|
Environmental and safety |
|
Operating
Temp. |
0oC
to 40oC (32oF to 104oF) UL tested
at 25oC (77oF) |
|
Storage Temp. |
-20oC
to 60oC (-4oF to 140oF) |
|
Audible Noise |
< 45 dBA
typical |
|
Relative
Humidity |
5 to 95%
non-condensing |
|
Operating
Altitude |
Up to 3,000
meters above sea level |
|
Safety
Markings |
UL and CSA;
230 volt models also CE,VDE,S,FI,N, and D |
|
Safety
Certifications |
UL 1778, CSA
22.2, No. 107.1; 230 volt models also EN 50091-1 and IEC 60950 |
|
EMC Markings |
FCC; 120 volt
models also VCCI; 230 volt models also CE |
|
Emissions |
FCC Class B
(2000-3000 VA Class A); 230 volt models also EN 50091-2, EN 55022
and IEC 61000-3-2 |
|
Immunity |
vEN 50091-2,
IEC 61000-4-2,3,4,5 and ANSI C62.41 Cat B (formerly IEEE 587) |
|
Surge
Suppression |
Manufactured
with surge suppressors that meet UL1449 |
|
REPO Port
(rack-mount models) |
Meets NEC code
645-11 intent and UL requirements |
|
* Due to
continuing product improvement programs, Specifications subject to
change without notice |
Rack-mount Model Selection Guide
|
120 VAC1,
60 Hz Models |
|
Model |
Power Out (VA/Watt) |
Input Connection |
Output Connections |
Maximum Output Current (Amp) |
Dimensions WxHxD (in/cm) |
Unit Weight (lb/kg) |
Ship Weight (lb/kg) |
|
PW5119 1000 1K
RM |
1000/670 |
5-15P
(detachable) |
(6)5-15R2 |
8.7 |
19.0x3.5x18.6/
48.2x8.9x47.25 |
58/26 |
65/29 |
|
PW5119 1.5K RM |
1440/960 |
5-15P
(detachable) |
(6)5-15R2 |
12.0 |
19.0x3.5x18.6/
48.2x8.9x47.25 |
58/26 |
65/29 |
|
PW5119 2K RM |
1920/1400 |
5-20P |
(9)5-15R3 |
16.0 |
19.0x5.25x22.3/ 48.2x13.3x56.65 |
132/60 |
142/64 |
|
PW5119 3K RM |
2880/2250 |
L5-30P |
(9)5-15R &
(1)L5-30R3 |
24.0 |
19.0x5.25x22.3/ 48.2x13.3x56.65 |
132/60 |
142/64 |
|
230 VAC4, 50/60 Hz Models |
|
PW5119 1Ki RM |
1000/670 |
IEC-320, 10A |
(6)IEC-3202 |
4.4 |
19.0x3.5x18.6/
48.2x8.9x47.25 |
58/26 |
65/29 |
|
PW5119 1.5Ki
RM |
1500/960 |
IEC-320, 10A |
(6)IEC-3202 |
6.5 |
>19.0x3.5x18.6/ 48.2x8.9x47.25 |
58/26 |
65/29 |
|
PW5119 2Ki RM |
2000/1400 |
IEC-320, 10A |
(9)IEC-3203 |
8.7 |
19.0x5.25x22.3/ 48.2x13.3x56.65 |
132/60 |
142/64 |
|
PW5119 2.4Ki
RM |
2300/1600 |
IEC-320, 10A |
(9)IEC-3203 |
10.0 |
19.0x5.25x22.3/ 48.2x13.3x56.65 |
132/60 |
142/64 |
|
PW5119 3Ki RM |
3000/2250 |
IEC-320, 16A |
(9)IEC-320 &
(1)IEC-320 (16A)3 |
13.0 |
19.0x5.25x22.3/ 48.2x13.3x56.65 |
132/60 |
142/64 |
1User
selectable for 100,110,120, or 127 VAC. With 100 or 110 V
selected, 120 VAC units can operate at 50 Hz.
2Divided into 2 load segments (receptacle groups).
3Divided into 3 load segments (receptacle groups).
4User selectable for 208,220,230, or 240 VAC.
519-inch wide front panel with 17.25-inch wide chassis.
PW5119-MK15 (1000/1500VA) and PW5119-MK23 (2000/3000VA)
mounting kits are sold separately. |
Battery Run Times
(in minutes)
|
Load |
PW5119 1K(i) RM |
PW5119 1.5K(i) RM |
PW5119 2K(i) RM |
PW5119 2.4K(i) RM |
PW5119 3K(i) RM |
|
300 VA |
40 |
67 |
112 |
187 |
187 |
|
500 VA |
20 |
32 |
68 |
112 |
112 |
|
700 VA |
12 |
23 |
48 |
80 |
80 |
|
1000 VA |
7 |
13 |
27 |
45 |
45 |
|
1500 VA |
|
7 |
18 |
30 |
30 |
|
2000 VA |
|
|
11 |
19 |
19 |
|
2400 VA |
|
|
|
14 |
14 |
|
3000 VA |
|
|
|
|
11 |
*This guide
provides typical application information. Battery times are approximate
and may vary with equipment, configuration, disk access, battery age,
temperature.etc. |
|
PW5119 1000 PW5119 1000 RM PW5119 1500 PW5119 1500 RM PW5119 2000 PW5119 2000 RM PW5119 2400 PW5119 3000 PW5119 3000 RM
• PW5119 1000 • PW5119 1000 RM • PW5119 1500 • PW5119 1500 RM • PW5119 2000 • PW5119 2000 RM • PW5119 2400 • PW5119 3000 • PW5119 3000 RM •
|