Batteries Eaton Showcase UPS Technology Emergency Lighting Battery Chargers TVSS 9 Power Problems Olight Flashlights Problems with Power Factory Links Contact Us
PW5119 1000 PW5119 1000 RM PW5119 1500 PW5119 1500 RM PW5119 2000 PW5119 2000 RM PW5119 2400 PW5119 3000 PW5119 3000 RM
800-706-7009
A+ Rating with the Better Business Bureau

| |
• PW5119 1000 • PW5119 1000 RM • PW5119 1500 • PW5119 1500 RM • PW5119 2000 • PW5119 2000 RM • PW5119 2400 • PW5119 3000 • PW5119 3000 RM •

Eaton Powerware 5119-1500 PW5119-1500 PW51191500 UPS
Contact us @
800-706-7009 or click here for more information.


- Uninterruptible
power protection against power failures, power sags, power surges,
brownouts and line noise
-
Advanced Battery Management (ABM™) doubles battery service life.
- Buck and Double
Boost voltage regulation - conditions voltage without using battery power
- Rack-mount models
- conserve valuable rack space
- Bundled with power
management software - ensures data integrity
|
Rating: |
1000-3000VA; 400 and
600 VA models also available |
|
Voltage: |
100-127 VAC; 208-240
VAC |
|
Frequency: |
50 and 60 Hz |
|
Configuration: |
Cabinet and
rack-mount |
|
Topology: |
Line-Interactive
(pure sine wave output) |
- Compact rack-mount
models conserve valuable rack space.
Buck and Double Boost voltage regulation conditions voltage without
using battery power.
- LanSafe III/FailSafe
III
power management software ensures data integrity.
- Network Transient
Protector isolates network/telephone wiring.
- Hot-Swappable
Batteries simplify service.
-
Precision Power Control (separate receptacle groups) enables scheduled
shutdowns and maximized run time for critical devices.
- Accurate Battery
Testing. By shutting off the charger, the Powerware 5119 is able to test
the actual condition of the battery.
|
 |



Cabinet Specification
Details
|
Electrical Input |
|
Voltage |
120 and 230 VAC Nominal; see Model Selection
Guide for user selectable voltages |
|
On Line Voltage Range |
-30%, +20% for nominal voltages; user selectable extended range of
-35%, +20% (-30%, +15% for 127 and 240 VAC) |
|
Nominal
Input Frequency |
50/60 Hz; auto-selection (60 Hz only for 120 and 127 VAC) |
|
Frequency Tolerance |
Nominal +/-3 Hz |
|
Electrical Output |
|
Power Levels |
1000-3000 VA |
|
On Line Regulation |
-10%, +6%; within Computer Business Equipment Manufacturers
Association's Guidelines (-15%; +10% using extended range) |
|
On Battery
Regulation |
< +/-5% RMS |
|
Voltage Wave Shape (on battery) |
Sine wave, 3% THD |
|
Overload
(Normal Operation) |
Minimum 200% of full load for 15 cycles |
|
No Load Sleep Mode (Battery Mode) |
Outputs are turned off if <5% load is detected (selectable) |
|
Interconnecting Cords ( 230 VAC Models only) |
2 ea. IEC-320 (10 A); PRC3000i also includes 1 ea. IEC-320 (16A)
with stripped male end for rewirable plug |
|
Backup Time |
See Backup Times table |
|
Battery
Charging |
<3 hrs. to 90% usable capacity |
|
Battery Type |
Sealed, maintenance-free lead-acid; starved electrolyte |
|
Start-On-Battery |
Startup with UPS batteries in absence of utility power |
|
Environmental and safety |
|
Operating Temperature |
0oC to 40oC (32oF to 104oF) UL
tested at 25oC (77oF) |
|
Storage
Temp. |
-20oC to 60oC (-4oF to 140oF) |
|
Audible Noise |
< 45 dBA typical |
|
Relative
Humidity |
5 to 95% non-condensing |
|
Operating Altitude |
Up to 3,000 meters above sea level |
|
Safety
Markings |
UL and CSA; 230 volt models also CE,VDE,S,FI,N, and D |
|
Safety Certifications |
UL 1778, CSA 22.2, No. 107.1; 230 volt models also EN 50091-1 and
IEC 60950 |
|
EMC Markings |
FCC; 120 volt models also VCCI; 230 volt models also CE |
|
Emissions |
FCC Class B
(2000-3000 VA Class A); 230 volt models also EN 50091-2, EN 55022
and IEC 61000-3-2 |
|
Immunity |
EN 50091-2, IEC 61000-4-2,3,4,5 and ANSI C62.41 Cat B (formerly IEEE
587) |
|
Surge Suppression |
Manufactured with surge suppressors that meet UL1449 |
|
Network
Transient Protector (cabinet models) |
In and out RJ11 jack for telephone/modem protection (120 VAC models
only) or RJ45 for 10Base-T network cable |
|
* Due to continuing product improvement programs, specifications
subject to change without notice |
Model Selection Guide
|
120 VAC1,
60 Hz Models |
|
Product Name |
Power Out (VA/Watt) |
Input Connection |
Output Connections |
Maximum Output Current (Amp) |
Dimensions WxHxD (in/cm) |
Unit Weight (lb/kg) |
Ship Weight (lb/kg) |
|
PW5119 1000 |
1000/670 |
5-15P |
(6)5-15R2 |
8.3 |
7.0x8.8x17.1 /
17.8x22.3x43.4 |
43/20 |
48/22 |
|
PW5119 1500 |
1440/960 |
5-15P |
(6)5-15R2 |
12.0 |
7.0x8.8x17.1 /
17.8x22.3x43.4 |
57/26 |
62/28 |
|
PW5119 2000 |
1920/1400 |
5-20P |
(6)5-15R &
(2)5-20R4 |
16.0 |
7.0x8.8x17.1 /
17.8x22.3x43.4 (x2)3 |
32/15 |
91/41 |
|
Pw5119 2400 |
2400/1600 |
L5-30P |
(6)5-15R &
(1)L5-30R4 |
20.0 |
7.0x8.8x17.1 /
17.8x22.3x43.4 (x2)5 |
36/16 |
110/50 |
|
PW5119 3000 |
2880/2250 |
L5-30P |
(6)5-15R &
(1)L5-30R4 |
24.0 |
7.0x8.8x17.1 /
17.8x22.3x43.4 (x2)5 |
41/19 |
115/52 |
|
230 VAC6, 50/60 Hz Models |
|
PW5119 1000i |
1000/670 |
IEC-320, 10A |
(6)IEC-3202 |
4.4 |
7.0x8.8x17.1 /
17.8x22.3x43.4 |
43/20 |
48/22 |
|
PW5119 1500i |
1500/960 |
IEC-320, 10A |
(6)IEC-3202 |
6.5 |
7.0x8.8x17.1 /
17.8x22.3x43.4 |
57/26 |
62/28 |
|
PW5119 2000i |
2000/1400 |
IEC-320, 10A |
(9)IEC-3204 |
8.7 |
7.0x8.8x17.1 /
17.8x22.3x43.4 (x2)3 |
31/14 |
90/41 |
|
PW5119 2400i |
2300/1600 |
IEC-320, 10A |
(9)IEC-3204 |
10.0 |
7.0x8.8x17.1 /
17.8x22.3x43.4 (x2)5 |
34/15 |
108/49 |
|
PW5119 3000i |
3000/2250 |
IEC-320, 16A |
(9)IEC-3204 |
13.0 |
7.0x8.8x17.1 /
17.8x22.3x43.4 (x2)5 |
39/18 |
113/51 |
|
Battery Boxes (for 2000-3000 VA models only)7 |
|
PW5119 1048 BP |
48 VDC, 10 AHr |
cord w/
connector |
--- |
--- |
7.0x8.8x17.1 /
17.8x22.3x43.4 |
47/21 |
---7 |
|
PW5119 1748 BP |
48 VDC, 17 AHr |
cord w/
connector |
--- |
--- |
7.0x8.8x17.1 /
17.8x22.3x43.4 |
63/29 |
---7 |
|
|
|
|
|
|
|
|
|
1User
selectable for 100,110,120, or 127 VAC. With 100 or 110 V
selected, 120 VAC units can
operate at 50 Hz.
2Divided into 2 load segments (receptacle groups).
3Includes Battery Box PW5119 1048 BP.
4Divided into 3 load segments (receptacle groups).
5Includes Battery Box PW5119 1748 BP.
6User selectable for 208,220,230, or 240 VAC.
7Battery box and electronics ship together in one box. |
Battery Run Times
(in minutes)
|
Load |
PW5119 1K(i) RM |
PW5119 1.5K(i) RM |
PW5119 2K(i) RM |
PW5119 2.4K(i) RM |
PW5119 3K(i) RM |
|
300 VA |
40 |
67 |
112 |
187 |
187 |
|
500 VA |
20 |
32 |
68 |
112 |
112 |
|
700 VA |
12 |
23 |
48 |
80 |
80 |
|
1000 VA |
7 |
13 |
27 |
45 |
45 |
|
1500 VA |
|
7 |
18 |
30 |
30 |
|
2000 VA |
|
|
11 |
19 |
19 |
|
2400 VA |
|
|
|
14 |
14 |
|
3000 VA |
|
|
|
|
11 |
*This guide
provides typical application information. Battery times are approximate
and may vary with equipment, configuration, disk access, battery age,
temperature.etc.
|
|
PW5119 1000 PW5119 1000 RM PW5119 1500 PW5119 1500 RM PW5119 2000 PW5119 2000 RM PW5119 2400 PW5119 3000 PW5119 3000 RM
• PW5119 1000 • PW5119 1000 RM • PW5119 1500 • PW5119 1500 RM • PW5119 2000 • PW5119 2000 RM • PW5119 2400 • PW5119 3000 • PW5119 3000 RM •
|