Powerware 5119-1000 RM PW5119-1000RM PW51191000 RM UPS 

Powerware 5119

Special features
bulletUninterruptible power protection against power failures, power sags, power surges, brownouts and line noise
bullet Advanced Battery Management (ABM™) doubles battery service life.
bulletBuck and Double Boost voltage regulation - conditions voltage without using battery power
bulletRack-mount models - conserve valuable rack space
bulletBundled with power management software - ensures data integrity
Rating: 1000-3000VA; 400 and 600 VA models also available
Voltage: 100-127 VAC; 208-240 VAC
Frequency: 50 and 60 Hz
Configuration: Cabinet and rack-mount
Topology: Line-Interactive (pure sine wave output)

 

bulletCompact rack-mount models conserve valuable rack space. Buck and Double Boost voltage regulation conditions voltage without using battery power.
bulletLanSafe III/FailSafe III power management software ensures data integrity.
bulletNetwork Transient Protector isolates network/telephone wiring.
bulletHot-Swappable Batteries simplify service.
bullet Precision Power Control (separate receptacle groups) enables scheduled shutdowns and maximized run time for critical devices.
bulletAccurate Battery Testing. By shutting off the charger, the Powerware 5119 is able to test the actual condition of the battery.

Rack-mount

The Powerware 5119 Rack-mount packs the same award-winning technology of the cabinet models into a compact design which fits into standard 19 inch equipment racks. By limiting the rack height of the UPS, the Powerware 5119 conserves room for other critical equipment such as servers and disk arrays. 1000 and 1500 VA models measure on 2U (3.5") high and 2000 - 3000 VA models are an industry-leading 3U (5.25")

 

Powerware 5119

Specification details

Rack Specification Details

Electrical Input

 Voltage 120 and 230 VAC Nominal; see Model Selection Guide for user selectable voltages
 On Line Voltage Range  -30%, +20% for nominal voltages; user selectable extended range of -35%, +20% (-30%, +15% for 127 and 240 VAC)
 Nominal Input  Frequency

 50/60 Hz; auto-selection (60 Hz only for 120 and 127 VAC)

 Frequency Tolerance

 Nominal +/-3 Hz

Electrical Output

 Power Levels

1000-3000 VA

 On Line Regulation

-10%, +6%; within Computer Business Equipment Manufacturers Association's Guidelines (-15%; +10% using extended range)

 On Battery Regulation

< +/-5% RMS

 Voltage Wave Shape (on  battery)

Sine wave, 3% THD

 Overload (Normal  Operation)

Minimum 200% of full load for 15 cycles

 No Load Sleep Mode  (Battery Mode) Outputs are turned off if <5% load is detected (selectable)
 Interconnecting Cords ( 230 VAC Models only)

2 ea. IEC-320 (10 A); PRC3000i-RM also include: 1 ea. IEC-320 (16A) with stripped male end for rewirable plug

 Backup Time

See Backup Times table

 Battery Charging

<3 hrs. to 90% usable capacity

 Battery Type

Sealed, maintenance-free lead-acid; starved electrolyte

 Start-On-Battery

Startup with UPS batteries in absence of utility power

Environmental and safety

 Operating Temp.

0oC to 40oC (32oF to 104oF) UL tested at 25oC (77oF)

 Storage Temp.

-20oC to 60oC (-4oF to 140oF)

 Audible Noise

 < 45 dBA typical

 Relative Humidity

 5 to 95% non-condensing

 Operating Altitude

 Up to 3,000 meters above sea level

 Safety Markings

UL and CSA; 230 volt models also CE,VDE,S,FI,N, and D

 Safety Certifications

 UL 1778, CSA 22.2, No. 107.1; 230 volt models also EN 50091-1 and IEC 60950

 EMC Markings

FCC; 120 volt models also VCCI; 230 volt models also CE

 Emissions

FCC Class B (2000-3000 VA Class A); 230 volt models also EN 50091-2, EN 55022 and IEC 61000-3-2

 Immunity

vEN 50091-2, IEC 61000-4-2,3,4,5 and ANSI C62.41 Cat B (formerly IEEE 587)

 Surge Suppression

Manufactured with surge suppressors that meet UL1449

 REPO Port (rack-mount  models)

Meets NEC code 645-11 intent and UL requirements

 * Due to continuing product improvement programs, Specifications subject to change without notice

 
Rack-mount Model Selection Guide

120 VAC1, 60 Hz Models

Model

Power Out (VA/Watt)

Input Connection

Output Connections

Maximum Output Current (Amp)

Dimensions WxHxD (in/cm)

Unit Weight (lb/kg)

Ship Weight (lb/kg)

PW5119 1000 1K RM 1000/670 5-15P
(detachable)
(6)5-15R2 8.7 19.0x3.5x18.6/ 48.2x8.9x47.25 58/26 65/29
PW5119 1.5K RM 1440/960 5-15P
(detachable)
(6)5-15R2 12.0 19.0x3.5x18.6/ 48.2x8.9x47.25 58/26 65/29
PW5119 2K RM 1920/1400 5-20P (9)5-15R3 16.0 19.0x5.25x22.3/ 48.2x13.3x56.65 132/60 142/64
PW5119 3K RM 2880/2250 L5-30P (9)5-15R & (1)L5-30R3 24.0 19.0x5.25x22.3/ 48.2x13.3x56.65 132/60 142/64


230 VAC4, 50/60 Hz Models

PW5119 1Ki RM 1000/670 IEC-320, 10A (6)IEC-3202 4.4 19.0x3.5x18.6/ 48.2x8.9x47.25 58/26 65/29
PW5119 1.5Ki RM 1500/960 IEC-320, 10A (6)IEC-3202 6.5 >19.0x3.5x18.6/ 48.2x8.9x47.25 58/26 65/29
PW5119 2Ki RM 2000/1400 IEC-320, 10A (9)IEC-3203 8.7 19.0x5.25x22.3/ 48.2x13.3x56.65 132/60 142/64
PW5119 2.4Ki RM 2300/1600 IEC-320, 10A (9)IEC-3203 10.0 19.0x5.25x22.3/ 48.2x13.3x56.65 132/60 142/64
PW5119 3Ki RM 3000/2250 IEC-320, 16A (9)IEC-320 & (1)IEC-320 (16A)3 13.0 19.0x5.25x22.3/ 48.2x13.3x56.65 132/60 142/64
1User selectable for 100,110,120, or 127 VAC. With 100 or 110 V selected, 120 VAC units can operate at 50 Hz.
2Divided into 2 load segments (receptacle groups).
3Divided into 3 load segments (receptacle groups).
4User selectable for 208,220,230, or 240 VAC.
519-inch wide front panel with 17.25-inch wide chassis. PW5119-MK15 (1000/1500VA) and PW5119-MK23 (2000/3000VA)
  mounting kits are sold separately.

 
Battery Run Times
(in minutes)

 Load

 PW5119 1K(i) RM PW5119 1.5K(i) RM PW5119 2K(i) RM PW5119 2.4K(i) RM PW5119 3K(i) RM
300 VA 40 67 112 187 187
500 VA 20 32 68 112 112
700 VA 12 23 48 80 80
1000 VA 7 13 27 45 45
1500 VA   7 18 30 30
2000 VA     11 19 19
2400 VA       14 14
3000 VA         11

*This guide provides typical application information. Battery times are approximate and may vary with equipment, configuration, disk access, battery age, temperature.etc.

Powerware 5119-1000 RM PW5119-1000RM PW51191000 RM UPS  Powerware 5119-1000 RM PW5119-1000RM PW51191000 RM UPS  Powerware 5119-1000 RM PW5119-1000RM PW51191000 RM UPS  Powerware 5119-1000 RM PW5119-1000RM PW51191000 RM UPS  Powerware 5119-1000 RM PW5119-1000RM PW51191000 RM UPS  Powerware 5119-1000 RM PW5119-1000RM PW51191000 RM UPS  Powerware 5119-1000 RM PW5119-1000RM PW51191000 RM UPS  Powerware 5119-1000 RM PW5119-1000RM PW51191000 RM UPS  Powerware 5119-1000 RM PW5119-1000RM PW51191000 RM UPS  Powerware 5119-1000 RM PW5119-1000RM PW51191000 RM UPS  Powerware 5119-1000 RM PW5119-1000RM PW51191000 RM UPS  Powerware 5119-1000 RM PW5119-1000RM PW51191000 RM UPS  Powerware 5119-1000 RM PW5119-1000RM PW51191000 RM UPS  Powerware 5119-1000 RM PW5119-1000RM PW51191000 RM UPS  Powerware 5119-1000 RM PW5119-1000RM PW51191000 RM UPS  Powerware 5119-1000 RM PW5119-1000RM PW51191000 RM UPS  Powerware 5119-1000 RM PW5119-1000RM PW51191000 RM UPS 

 

PW5119 1000 PW5119 1000 RM PW5119 1500 PW5119 1500 RM PW5119 2000 PW5119 2000 RM PW5119 2400 PW5119 3000 PW5119 3000 RM PW5119 1000 PW5119 1000 RM PW5119 1500 PW5119 1500 RM PW5119 2000 PW5119 2000 RM PW5119 2400 PW5119 3000 PW5119 3000 RM PW5119 1000 PW5119 1000 RM PW5119 1500 PW5119 1500 RM PW5119 2000 PW5119 2000 RM PW5119 2400 PW5119 3000 PW5119 3000 RM

 

 

 

Home - 9 Power Problems - Problems with Power - APC - Powerware - MinuteMan - MGE - Liebert - Batteries - Chargers / Rectifiers - Emergency Lighting - Service - Factory Links

 Contact Us

Power Factor Inc.

2526 Manana Dr – Suite 102 – Dallas – Texas – 75220

NO DISSATISFIED CUSTOMERS!

Since 1995

While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.