Powerware 5119

Powerware 5119

Special features
bulletUninterruptible power protection against power failures, power sags, power surges, brownouts and line noise
bullet Advanced Battery Management (ABM™) doubles battery service life.
bulletBuck and Double Boost voltage regulation - conditions voltage without using battery power
bulletRack-mount models - conserve valuable rack space
bulletBundled with power management software - ensures data integrity
Rating: 1000-3000VA; 400 and 600 VA models also available
Voltage: 100-127 VAC; 208-240 VAC
Frequency: 50 and 60 Hz
Configuration: Cabinet and rack-mount
Topology: Line-Interactive (pure sine wave output)

 

bulletCompact rack-mount models conserve valuable rack space. Buck and Double Boost voltage regulation conditions voltage without using battery power.
bulletLanSafe III/FailSafe III power management software ensures data integrity.
bulletNetwork Transient Protector isolates network/telephone wiring.
bulletHot-Swappable Batteries simplify service.
bullet Precision Power Control (separate receptacle groups) enables scheduled shutdowns and maximized run time for critical devices.
bulletAccurate Battery Testing. By shutting off the charger, the Powerware 5119 is able to test the actual condition of the battery.

 

 

Powerware 5119

Specification details

Cabinet Specification Details
 

Electrical Input

 Voltage

120 and 230 VAC Nominal; see Model Selection Guide for user selectable voltages

 On Line Voltage Range

-30%, +20% for nominal voltages; user selectable extended range of -35%, +20% (-30%, +15% for 127 and 240 VAC)

 Nominal Input  Frequency

50/60 Hz; auto-selection (60 Hz only for 120 and 127 VAC)

 Frequency Tolerance

Nominal +/-3 Hz

Electrical Output

 Power Levels

1000-3000 VA

 On Line Regulation

-10%, +6%; within Computer Business Equipment Manufacturers Association's Guidelines (-15%; +10% using extended range)

 On Battery Regulation

< +/-5% RMS

 Voltage Wave Shape (on  battery)

Sine wave, 3% THD

 Overload (Normal  Operation)

Minimum 200% of full load for 15 cycles

 No Load Sleep Mode  (Battery Mode)

Outputs are turned off if <5% load is detected (selectable)

 Interconnecting Cords ( 230 VAC Models only)

2 ea. IEC-320 (10 A); PRC3000i also includes 1 ea. IEC-320 (16A) with stripped male end for rewirable plug

 Backup Time

See Backup Times table

 Battery Charging

<3 hrs. to 90% usable capacity

 Battery Type

Sealed, maintenance-free lead-acid; starved electrolyte

 Start-On-Battery

Startup with UPS batteries in absence of utility power

Environmental and safety

 Operating Temperature

0oC to 40oC (32oF to 104oF) UL tested at 25oC (77oF)

 Storage Temp.

-20oC to 60oC (-4oF to 140oF)

 Audible Noise

< 45 dBA typical

 Relative Humidity

5 to 95% non-condensing

 Operating Altitude

Up to 3,000 meters above sea level

 Safety Markings

UL and CSA; 230 volt models also CE,VDE,S,FI,N, and D

 Safety Certifications

UL 1778, CSA 22.2, No. 107.1; 230 volt models also EN 50091-1 and IEC 60950

 EMC Markings

FCC; 120 volt models also VCCI; 230 volt models also CE

 Emissions FCC Class B (2000-3000 VA Class A); 230 volt models also EN 50091-2, EN 55022 and IEC 61000-3-2
 Immunity

EN 50091-2, IEC 61000-4-2,3,4,5 and ANSI C62.41 Cat B (formerly IEEE 587)

 Surge Suppression

Manufactured with surge suppressors that meet UL1449

 Network Transient  Protector (cabinet  models)

In and out RJ11 jack for telephone/modem protection (120 VAC models only) or RJ45 for 10Base-T network cable

 * Due to continuing product improvement programs, specifications subject to change without notice


Model Selection Guide

120 VAC1, 60 Hz Models

 Product  Name

Power Out (VA/Watt)

Input Connection

Output Connections

Maximum Output Current (Amp)  Dimensions WxHxD (in/cm) Unit Weight (lb/kg) Ship Weight (lb/kg)
PW5119 1000 1000/670 5-15P (6)5-15R2 8.3 7.0x8.8x17.1 / 17.8x22.3x43.4 43/20 48/22
PW5119 1500 1440/960 5-15P (6)5-15R2 12.0 7.0x8.8x17.1 / 17.8x22.3x43.4 57/26 62/28
PW5119 2000 1920/1400 5-20P (6)5-15R & (2)5-20R4 16.0 7.0x8.8x17.1 / 17.8x22.3x43.4 (x2)3 32/15 91/41
Pw5119 2400 2400/1600 L5-30P (6)5-15R & (1)L5-30R4 20.0 7.0x8.8x17.1 / 17.8x22.3x43.4 (x2)5 36/16 110/50
PW5119 3000 2880/2250 L5-30P (6)5-15R & (1)L5-30R4 24.0 7.0x8.8x17.1 / 17.8x22.3x43.4 (x2)5 41/19 115/52


230 VAC6, 50/60 Hz Models

PW5119 1000i 1000/670 IEC-320, 10A (6)IEC-3202 4.4 7.0x8.8x17.1 / 17.8x22.3x43.4 43/20 48/22
PW5119 1500i 1500/960 IEC-320, 10A (6)IEC-3202 6.5 7.0x8.8x17.1 / 17.8x22.3x43.4 57/26 62/28
PW5119 2000i 2000/1400 IEC-320, 10A (9)IEC-3204 8.7 7.0x8.8x17.1 / 17.8x22.3x43.4 (x2)3 31/14 90/41
PW5119 2400i 2300/1600 IEC-320, 10A (9)IEC-3204 10.0 7.0x8.8x17.1 / 17.8x22.3x43.4 (x2)5 34/15 108/49
PW5119 3000i 3000/2250 IEC-320, 16A (9)IEC-3204 13.0 7.0x8.8x17.1 / 17.8x22.3x43.4 (x2)5 39/18 113/51

Battery Boxes (for 2000-3000 VA models only)7

PW5119 1048 BP 48 VDC, 10 AHr cord w/ connector --- --- 7.0x8.8x17.1 / 17.8x22.3x43.4 47/21 ---7
PW5119 1748 BP 48 VDC, 17 AHr cord w/ connector --- --- 7.0x8.8x17.1 / 17.8x22.3x43.4 63/29 ---7
               
1User selectable for 100,110,120, or 127 VAC. With 100 or 110 V selected, 120 VAC units can
  operate at 50 Hz.
2Divided into 2 load segments (receptacle groups).
3Includes Battery Box PW5119 1048 BP.
4Divided into 3 load segments (receptacle groups).
5Includes Battery Box PW5119 1748 BP.
6User selectable for 208,220,230, or 240 VAC.
7Battery box and electronics ship together in one box.


Battery Run Times
(in minutes)

 Load

 PW5119 1K(i) RM PW5119 1.5K(i) RM PW5119 2K(i) RM PW5119 2.4K(i) RM PW5119 3K(i) RM
300 VA 40 67 112 187 187
500 VA 20 32 68 112 112
700 VA 12 23 48 80 80
1000 VA 7 13 27 45 45
1500 VA   7 18 30 30
2000 VA     11 19 19
2400 VA       14 14
3000 VA         11

*This guide provides typical application information. Battery times are approximate and may vary with equipment, configuration, disk access, battery age, temperature.etc.

 

Powerware 5119-1000 PW5119-1000 PW51191000  UPS  Powerware 5119-1000 PW5119-1000 PW51191000  UPS  Powerware 5119-1000 PW5119-1000 PW51191000  UPS  Powerware 5119-1000 PW5119-1000 PW51191000  UPS  Powerware 5119-1000 PW5119-1000 PW51191000  UPS  Powerware 5119-1000 PW5119-1000 PW51191000  UPS  Powerware 5119-1000 PW5119-1000 PW51191000  UPS  Powerware 5119-1000 PW5119-1000 PW51191000  UPS  Powerware 5119-1000 PW5119-1000 PW51191000  UPS  Powerware 5119-1000 PW5119-1000 PW51191000  UPS  Powerware 5119-1000 PW5119-1000 PW51191000  UPS  Powerware 5119-1000 PW5119-1000 PW51191000  UPS  Powerware 5119-1000 PW5119-1000 PW51191000  UPS  Powerware 5119-1000 PW5119-1000 PW51191000  UPS  Powerware 5119-1000 PW5119-1000 PW51191000  UPS  Powerware 5119-1000 PW5119-1000 PW51191000  UPS  Powerware 5119-1000 PW5119-1000 PW51191000  UPS  Powerware 5119-1000 PW5119-1000 PW51191000  UPS  Powerware 5119-1000 PW5119-1000 PW51191000  UPS 

PW3105 PW3110 PW5110 PW5115 Tower PW5115 Rack PW5119 PW5125 Tower PW5125 Rack/Tower PW5140 Prestige PW9104 PW9120 PW9125 PW9140 PW9150 PW9155 PW9170 PW9170+ Ferrups Plus 18 Plus 36 PW9305 PW9330 PW9390 PW9315 BladeUPS PW9355 PW3105 PW3110 PW5110 PW5115 Tower PW5115 Rack PW5119 PW5125 Tower PW5125 Rack/Tower PW5140 Prestige PW9104 PW9120 PW9125 PW9140 PW9150 PW9155 PW9170 PW9170+ Ferrups Plus 18 Plus 36 PW9305 PW9330 PW9390 PW9315 BladeUPS PW9355 PW3105 PW3110 PW5110 PW5115 Tower PW5115 Rack PW5119 PW5125 Tower PW5125 Rack/Tower PW5140 Prestige PW9104 PW9120 PW9125 PW9140 PW9150 PW9155 PW9170 PW9170+ Ferrups Plus 18 Plus 36 PW9305 PW9330 PW9390 PW9315 BladeUPS PW9355

 

 

 

 

Home - 9 Power Problems - Problems with Power - APC - Powerware - MinuteMan - MGE - Liebert - Batteries - Chargers / Rectifiers - Emergency Lighting - Service - Factory Links

 Contact Us

Power Factor Inc.

2526 Manana Dr – Suite 102 – Dallas – Texas – 75220

NO DISSATISFIED CUSTOMERS!

Since 1995

While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.