Powerware 5115-1400 PW5115-1400 PW51151400 UPS 

Powerware 5115

Special features
bulletAdvanced Battery Management (ABM™)doubles battery service life.
bulletBuck and Boost voltage regulation corrects incoming voltage fluctuations.
bulletPure sine wave output delivers smooth continuous power.
bulletEnhanced battery recharge time quickly prepares UPS for the next power outage.
bulletNetwork Transient Protector isolates equipment from "back door" power surges traveling through network and phone lines.
bulletHot-Swappable Batteries simplify service and extend service life of UPS.
bulletBundled with power management software to ensure data integrity.
Rating: 500-1400 VA
Voltage: 100-120 Vac; 220/230/240 Vac
Frequency: 50 and 60 Hz (auto-sensing)
Configuration: Tower
   
h_5115.gif (830 bytes)

Specification details

 

Electrical Input

 Voltage 120 and 230 Vac Nominal; see Model Selection Guide for user-selectable voltages
 On Line Voltage Range +20% for nominal voltage at full load
 Nominal Input Frequency

45-65 Hz, 50/60 Hz; auto-sensing

 Input Protection

120V models: Resettable circuit breaker
230V models: AC source overcurrent protection device (required)

 Connection

120V models: 6 ft. cord w/5-I5P
230V models: IEC-320, 10A male connector

Electrical Output

 Power Levels

 500-1400 VA

 Online Regulation

 -10%, +6% of nominal voltage

 On Battery Voltage Regulation

 +/-5% of nominal voltage; -10% after low battery warning

 On Battery Frequency Regulation

 +/-0.1 Hz of nominal frequency

 Voltage Wave Shape

 Sine wave (during normal and battery operation)

 Connections

 See Model Selection Guide

 Interconnecting Cords (230V models)

 2 ea. IEC-320, 10A

Indicators and Controls

 Front Panel LEDs

 Power on, on battery, overload, and battery fault

 Front Panel Buttons

 On/Off and alarm silence/self-test

 Communications Port

 DB9 female (UPS ships with communications cable); USB Interface Adapter is optional

 Power Factor

 500 VA: 0.64
750/1000 VA: 0.67
1400 VA: 0.68

Battery

 Battery Type

 Sealed, maintenance-free lead-acid; starved electrolyte

 Battery Description

 500 VA: (1) 12V, 9 Ah
750 VA: (2) 12V, 7.2 Ah
1000 VA: (2) 12V, 9 Ah
1400 VA: (3) 12V, 9 Ah

 Battery Recharge

 < 3 hours to 90% capacity

 Battery Runtime

 5 minutes minimum; See Battery Runtimes table

 Start-On-Battery

 Startup with UPS batteries in absence of utility power

General

 Topology

 Line-interactive

 Dimensions and Weight

 see Model Selection Guide

 Network Transient Protector

 In and out RJ11 jack for telephone/modem protection (120V models only) or RJ45 for 10Base-T network cable; UL497A tested

Environmental and safety

 Operating Temperature

0oC to 40oC (32oF to 104oF) UL tested at 25oC (77oF)

 Safety Markings

 UL, cUL, and CSA; 230V models also CE and TUV

 Safety Conformance

 UL 1778, CAN/CSA C22.2, No. 107.1; 230V models also EN 50091-1-1 and IEC 60950

 EMC Markings

 FCC Class B; 230V models also CE (EN50091-2) and C-Tick

 Surge Suppression

 ANSI C62.41 Category A (formerly IEEE 587)

 Immunity

 IEC 801-2, -3, -4

 Transit/Storage Temp.

-15oC to 55oC (5oF to 131oF)

 Audible Noise

 < 45 dBA typical

 Relative Humidity

 5-95% non-condensing

 * Due to continuing product improvement programs, specifications subject to change without notice


 Model Selection Guide

Model Number

Power Out (VA/Watts) Input Connection Output Connections Dimensions WxHxD, (in./mm) Unit Weight (lb/kg)

120 VAC1, 60 Hz auto-sensing

PW5115 500 500/320 5-15P (4) 5-15R 7.6x5.9x10.6/193x150x270 17.2/7.8
PW5115 750 750/500 5-15P (4) 5-15R 7.6x5.9x13.2/193x150x335 27.3/12.4
PW5115 1000 1000/670 5-15P (6) 5-15R 7.6x5.9x13.2/193x150x335 27.8/12.6
PW5115 1400 1400/950 5-15P (6) 5-15R 7.6x5.9x15.4/193x150x390 37.0/16.8

230 VAC2, 60 Hz auto-sensing

PW5115 500i 500/320 IEC-320, 10A (4) IEC-320 7.6x5.9x10.6/193x150x270 17.2/7.8
PW5115 750i 750/500 IEC-320, 10A (4) IEC-320 7.6x5.9x13.2/193x150x335 27.3/12.4
PW5115 1000i 1000/670 IEC-320, 10A (6) IEC-320 7.6x5.9x13.2/193x150x335 27.8/12.6
PW5115 1400i 1400/950 IEC-320, 10A (6) IEC-320 7.6x5.9x15.4/193x150x390 37.0/16.8
1 Also user-selectable for 110V via rear panel DIP switches.
2 230V default; also user-selectable for 220 and 240V via rear panel DIP switches


Battery Run Times
(in minutes)

Load PW5115 500(i) PW5115 750(i) PW5115 1000(i) PW 5115 1400(i)
200 VA / 128 W

17

38

41

58

300 VA / 192 W

11

27

28

41

500 VA / 320 W

5

14

15

28

600 VA / 402 W10

9

10

19

750 VA / 503 W  

6

8

14

900 VA / 603 W

6

10

1000 VA / 670 W    

5

8

1200 VA / 804 W

6

1400 VA / 938 W      

5

*This guide provides typical application information. Battery times are approximate and may vary with equipment, configuration, disk access, battery age, temperature, etc.

 Powerware 5115-1400 PW5115-1400 PW51151400 UPS  Powerware 5115-1400 PW5115-1400 PW51151400 UPS  Powerware 5115-1400 PW5115-1400 PW51151400 UPS  Powerware 5115-1400 PW5115-1400 PW51151400 UPS  Powerware 5115-1400 PW5115-1400 PW51151400 UPS  Powerware 5115-1400 PW5115-1400 PW51151400 UPS  Powerware 5115-1400 PW5115-1400 PW51151400 UPS  Powerware 5115-1400 PW5115-1400 PW51151400 UPS  Powerware 5115-1400 PW5115-1400 PW51151400 UPS  Powerware 5115-1400 PW5115-1400 PW51151400 UPS  Powerware 5115-1400 PW5115-1400 PW51151400 UPS  Powerware 5115-1400 PW5115-1400 PW51151400 UPS  Powerware 5115-1400 PW5115-1400 PW51151400 UPS  Powerware 5115-1400 PW5115-1400 PW51151400 UPS  Powerware 5115-1400 PW5115-1400 PW51151400 UPS  Powerware 5115-1400 PW5115-1400 PW51151400 UPS  Powerware 5115-1400 PW5115-1400 PW51151400 UPS  Powerware 5115-1400 PW5115-1400 PW51151400 UPS  Powerware 5115-1400 PW5115-1400 PW51151400 UPS 

 

PW5115 500 PW5115 750 PW5115 1000 PW5115 1400 PW5115 500 PW5115 750 PW5115 1000 PW5115 1400 PW5115 500 PW5115 750 PW5115 1000 PW5115 1400

Home - 9 Power Problems - Problems with Power - APC - Powerware - MinuteMan - MGE - Liebert - Batteries - Chargers / Rectifiers - Emergency Lighting - Service - Factory Links

 Contact Us

Power Factor Inc.

2526 Manana Dr – Suite 102 – Dallas – Texas – 75220

NO DISSATISFIED CUSTOMERS!

Since 1995

While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.