Powerware Prestige UPS

 | Uninterruptible
power protection against power failures, power sags, power surges,
brownouts, line noise, high voltage spikes, frequency variation, ups,
switching transients and harmonic distortion |
 | True online design
- ensures continuous, clean power |
 | Cell Saver®
technology - reduces battery replacement costs |
 | Additional battery
packs - extend backup times |
 | Bundled with power
management software - ensures data integrity |
|
Rating: |
600 - 6000 VA |
|
Voltage: |
120 VAC; 200-240 VAC |
|
Frequency: |
50/60 Hz |
|
Configuration: |
Modular; cabinet and
rack-mount |
|
Topology: |
Online |
 |
True online design - ensures continuous, clean power. |
 | Cell Saver
Technology reduces battery replacement costs. |
 | Additional
Battery Packs available to extend backup times. |
 | External
Battery Packs available are hot-swappable to simplify maintenance.
|
 | Versatile,
Modular Design provides easy setup and service. |
 | FailSafe III
and LanSafe III
power management software included to ensure data integrity. |
 | Engine
Generator Compatible |
 | Ten-Year
Pro-rated Warranty is the longest in the industry (US and Canada).
|
 | Automatic
Internal Bypass adds redundant power path. |
 | Optional
Powerpass Modules provide galvanic isolation and external maintenance
bypass switch for easy serviceability.
|
|
|

|
| Read what
InternetWeek says about the Powerware 9 Prestige:
Keep the Power Running and Stay in
Charge with Powerware. |
|
|

|
|
Prestige 3000 Online Rack-Mount
(200 - 240 VAC)
The Prestige is
available in a compact rack-mount design which fits into standard 19-inch
racks and uses only 4U (7 inches) of valuable rack space. Power protection
integrates easily with servers, network communications devices and other
rack mount equipment. |
|
Hot-pluggable extended
battery trays are accessible from the front of the rack and can be added or
replaced without losing power to your critical equipment. Automatic battery
diagnostics alert you when batteries need to be replaced, before disaster
strikes.
Making the 3000
Rack-mount UPS an integral part of an SNMP network is easily accomplished using
the
ConnectUPS Network Connectivity Adapter complemented with OnliNet
Network Power Management software. By using the ConnectUPS Adapter for
communication with networked Prestige Rack-mount units running SNMP-based
network management software, customers can quickly and conveniently determine if
there is a power-related problem anywhere on the network. This virtually
eliminates costly downtime due to unexpected power outages or surges.


Low voltage details
|
Electrical |
|
Allowable Input Range
(without using batteries) |
650-2000 VA: 85-144
VAC (full load); 75-144 (half load)
3000 VA; 120 V: 90-144 VAC
3000 VA; 230 V: 160-276 VAC
4500/6000: 170-276 VAC |
|
Input Power Factor |
650-2000 VA: .95
typical @ full load
3000-6000 VA: .90 typical @full load |
|
Surge Protection |
120 volt input
models: Tested to IEEE 587/ANSI C62.41 Categories A & B
230 volt input models: per EN 50082-1, meets IEC 801-4, IEEE 587 |
|
Output Waveform |
Sine wave |
|
Output Regulation |
+/-3% |
|
Output Voltage THD |
650-2000 VA: <5%,
100% non-linear load
3000-6000 VA: <3%, linear load |
|
Load
Crest Ratio |
3:1 |
|
Common Mode Noise Rejection |
>60dB |
|
Transverse Mode Noise Rejection |
>80dB |
|
Mechanical |
|
Optional Battery Pack Weight |
Full pack: 52
lb/23.6 kg
Half pack (1000-2000 EXT models only): 29.5 lb/13.4 kg |
|
Optional Battery Pack Dimensions (H x W x D) |
5.6x9.9x15.8 in/
14.3x25.2x40.0 cm |
|
Battery |
|
Battery type |
Sealed, lead-acid;
maintenance free |
|
Recharge Time |
650-2000 VA: 4 hours
to 80% capacity
3000-6000 VA: 6 hours to 90% capacity |
|
Diagnostics |
Automatic on-line
test without exposing the load |
|
General |
|
Architecture |
True online,
double-conversion, powerline isolated |
|
Diagnostics |
Full system
self-test on power up |
|
UPS
Bypass |
Automatic on
overload or UPS failure |
|
Replacement Modules |
Hot-swappable
external battery packs and electronics via PowerPass Maintenance bypass
module |
|
Communications |
RS-232, LAN
contacts, AS/400, Novell, 3 COM |
|
Networks |
Connectivity via
Ethernet & Token Ring SNMP Adapter |
|
Safety |
All models: UL 1778,
CSA-C22.2 No. 107.1;EN 50091-1 for all models except 3000 VA, 120 V;
4500/600 VA: also EN60950 |
|
Environmental |
|
Audible Noise |
650-2000 VA: 45dBA @
1 meter
3000-6000 VA: 50dBA @ 1 meter |
|
Ambient Operating Temperature |
10 to 40oC
(50 to 104oF) |
|
Ambient Storage Temperature |
-20 to 60oC
(-4 to 140oF) |
|
Relative Humidity |
5-95% non-condensing |
|
EMI
Suppression |
All models: FCC Part
15, sub part J Class A; Class B available on selected models - 2kVA, 230
volt input models: also CISPR Class A |
|
Packaging |
No CFCs, recyclable |
Low voltage model selection guide
|
Model1 |
Input Voltage (VAC) |
Output Voltage (VAC) |
Frequency (Hz) |
Input Connection2 |
Output Connections |
Output Current (Amp) |
Dimensions HxWxD (cm) |
Unit Weight (lb/kg) |
|
650 - 3000 VA Models |
|
650VA/445W |
120 |
120 |
45 - 65 |
5-15P |
(4)5-15R |
5.4 |
5.6 x 9.9 x 15.8 |
28.5/12.93 |
| 800VA/560W |
120 |
120 |
45 - 65 |
5-15P |
(4)5-15R |
6.7 |
5.6 x 9.9 x 15.8 |
28.5/12.93 |
|
1000VA/700W |
120 |
120 |
45 - 65 |
5-15P |
(4)5-15R |
8.3 |
5.6 x 9.9 x 15.8 |
28.5/12.93 |
| 750VA/525W EXT |
120 |
120 |
45 - 65 |
5-15P |
(4)5-15R |
6.3 |
5.6 x 9.9 x 15.8 |
28.5/12.93 |
|
1000VA/700W EXT |
120 |
120 |
45 - 65 |
5-15P |
(4)5-15R |
8.3 |
5.6 x 9.9 x 15.8 |
33.0/14.93 |
| 1250VA/875W
EXT |
120 |
120 |
45 - 65 |
5-15P |
(4)5-15R |
10.4 |
5.6 x 9.9 x 15.8 |
33.0/14.93 |
|
1500VA/1050W EXT |
120 |
120 |
45 - 65 |
5-15P |
(4)5-15R |
12.5 |
5.6 x 9.9 x 15.8 |
33.0/14.93 |
| 2000VA/1300W
EXT |
120 |
120 |
45 - 65 |
5-20P |
(4)5-15R & (1)
5-20R |
16.0 |
5.6 x 9.9 x 15.8 |
33.0/14.93 |
|
3000VA/2100W |
120 |
120 |
45 - 65 |
L5-30P |
(1)5-15R & (1)
L5-30R |
25.5 |
11.2 x 9.9 x 15.84 |
68.5/31.14 |
|
2500 - 6000 VA Models with PowerPass Module |
| 2500VA/1750W |
200 - 2405 |
120/208, 120/240 |
45 - 65 |
IEC-320, 16 A |
See PowerPass Primer
3000 |
10.46 |
16.8 x 9.9 x 15.87 |
115.5/52.57 |
|
3000VA/2000W |
200 - 2405 |
120/208, 120/240 |
45 - 65 |
IEC-320, 16 A |
See PowerPass Primer
3000 |
12.56 |
16.8 x 9.9 x 15.87 |
115.5/52.57 |
| 4500VA/3000W6 |
200 - 2405 |
120/208, 120/240 |
45 - 65 |
L6-30P or
Hardwired |
See PowerPass Primer
6000 |
19.06 |
33.6 x 9.9 x 15.88 |
218.0/98.98 |
|
6000VA/4000W6 |
200 - 2405 |
120/208, 120/240 |
45 - 65 |
L6-30P or
Hardwired |
See PowerPass Primer
6000 |
25.06 |
33.6 x 9.9 x 15.88 |
218.0/98.98 |
1EXT
Models and 2500 - 6000VA models accommodate additional battery packs.
2Includes 6-foot (2 meter) detachable line cord with
region-specific plug, except hardwired models.
3With standard, internal battery.
4With UPS electronics an done battery pack stacked.
5200, 208, 220, 230, or 240 VAC.
6Based on 240 VAC.
8With UPS electronics, battery pack, and PowerPass stacked.
9With UPS electronics, two standard battery packs, and PowerPass
stacked.
650 Low voltage
battery run times (in minutes)
(Note:
more battery run times below)
Load (VA)
at 0.7 pf* |
Load
(W) |
650 |
800 |
1000 |
750 EXT |
1000 EXT |
1250 EXT |
1500 EXT |
|
200 |
140 |
37 |
37 |
37 |
68 |
68 |
68 |
68 |
|
400 |
280 |
22 |
22 |
22 |
32 |
32 |
32 |
32 |
|
600 |
420 |
12 |
12 |
12 |
20 |
20 |
20 |
20 |
|
800 |
560 |
- |
8 |
8 |
15** |
14 |
14 |
14 |
|
1000 |
700 |
- |
- |
6 |
- |
11 |
11 |
11 |
|
1250 |
875 |
- |
- |
- |
- |
- |
8 |
8 |
|
1500 |
1050 |
- |
- |
- |
- |
- |
- |
6 |
**750VA,
525W
External Battery Cabinet Configurations
(650 - 1500 VA Low
Voltage EXT Models)
|
Load
(VA) at 0.7 pf* |
Load
(W) |
1/2
Cabinet |
1
Cabinet |
1-1/2 Cabinet |
2
Cabinet |
2-1.2 Cabinet |
3
Cabinet |
3-1/2 Cabinet |
4
Cabinet |
|
200 |
140 |
143 |
216 |
290 |
364 |
438 |
513 |
589 |
663 |
|
400 |
280 |
69 |
115 |
158 |
198 |
239 |
280 |
320 |
362 |
|
600 |
420 |
43 |
73 |
105 |
137 |
165 |
194 |
221 |
249 |
|
800 |
560 |
33 |
56 |
80 |
106 |
134 |
156 |
178 |
202 |
|
1000 |
700 |
23 |
39 |
57 |
75 |
95 |
114 |
135 |
151 |
|
1250 |
875 |
17 |
30 |
42 |
56 |
70 |
86 |
102 |
118 |
|
1500 |
1050 |
14 |
23 |
32 |
43 |
55 |
67 |
78 |
91 |
*Typical
Power factor (PF)
2000 Low voltage
battery run times
(in
minutes)
Load (VA)
at 0.7 pf* |
Load
(W) |
Internal
UPS
Battery |
˝
Cab |
1
Cab |
1 ˝
Cab |
2
Cab |
2 ˝
Cab |
3
Cab |
3 ˝
Cab |
4
Cab |
|
200 |
140 |
72 |
150 |
228 |
306 |
384 |
463 |
542 |
620 |
700 |
|
400 |
280 |
34 |
74 |
122 |
166 |
209 |
251 |
294 |
337 |
380 |
|
600 |
420 |
22 |
47 |
78 |
113 |
145 |
175 |
204 |
235 |
265 |
|
800 |
650 |
15 |
33 |
56 |
81 |
107 |
135 |
157 |
179 |
203 |
|
1000 |
700 |
12 |
25 |
43 |
61 |
82 |
103 |
125 |
144 |
162 |
|
1250 |
900 |
9 |
19 |
32 |
47 |
61 |
77 |
95 |
112 |
130 |
|
1500 |
1000 |
7 |
15 |
25 |
37 |
49 |
61 |
74 |
88 |
102 |
|
2000 |
1300 |
5 |
10 |
17 |
24 |
32 |
41 |
50 |
59 |
69 |
*Typical
Power factor (PF)
3000 Low voltage
battery run times
(in
minutes)
|
Load
(VA) |
Load
(W) |
1
Pack |
2
Packs |
3
Packs |
|
400 |
280 |
72 |
150 |
227 |
| 800 |
560 |
36 |
79 |
122 |
|
1200 |
840 |
23 |
53 |
82 |
| 1600 |
1100 |
16 |
38 |
61 |
|
2000 |
1400 |
12 |
30 |
48 |
| 2500 |
1750 |
8 |
23 |
37 |
|
3000 |
2100 |
6.5 |
17 |
29 |
This guide provides
typical application information. Battery times are approximate and may vary
with equipment, configuration, disk access, battery age, temperature, etc.
|


High
voltage details
|
Electrical |
|
Allowable Input Range
(without using batteries) |
600-1800 VA: 140-276
VAC
3000 VA: 160-276 VAC
3000 VA (rack): 176-276 VAC
4500/6000: 176-276 VAC |
|
Input Power Factor |
.90 typical @ full
load |
|
Surge Protection |
per EN 50082-1,
tested to IEC 801-4, IEEE 587 |
|
Output Waveform |
Sine wave |
|
Output Regulation |
+/-3% |
|
Output Voltage THD |
600-1800 VA: <5%,
100% non-linear load
2500-6000 VA: <3%, linear load |
|
Load
Crest Ratio |
3:1 |
|
Common Mode Noise Rejection |
>60dB |
|
Transverse Mode Noise Rejection |
>80dB |
|
Battery |
|
Battery type |
Sealed, lead-acid;
maintenance free |
|
Recharge Time |
600-1800 VA: 8 hours
to 80% capacity
3000-6000 VA: 6 hours to 90% capacity
3000 VA (rack): 4 hours to 90% capacity (2 battery trays) |
|
Diagnostics |
Automatic on-line
test without exposing the load |
|
Optional Battery Pack Weight (cabinet models) |
Full pack: 52
lb/23.6 kg
Half pack (800-1800 EXT only): 29.5 lb/13.4 kg |
|
Optional Battery Pack (cabinet models;
H x W X D) |
5.6x9.9x15.8 in/
14.3x25.2x40.0 cm> |
|
General |
|
Architecture |
True online,
double-conversion, powerline isolated |
|
User
Interface |
5 segment LED
display with meters and alarms |
|
Operation |
Fully automatic,
touch-pad control |
|
Diagnostics |
Full system
self-test on power up |
|
UPS
Bypass |
Automatic on
overload or UPS failure |
|
Replacement Electronics (cabinet models) |
600-1800 VA:
Hot-swappable via PowerPass Maintenance bypass module |
|
Battery Service |
Hot-swappable,
external battery packs
3000 VA rack: hotpluggable battery trays (2 trays standard with unit) |
|
Communications |
RS-232, LAN
contacts, AS/400, Novell, 3 COM |
|
Networks |
Connectivity via
Ethernet & Token Ring SNMP Adapter |
|
Safety |
UL 1778, CSA-C22.2
No. 107.1; CE certification |
|
Environmental |
|
Audible Noise |
600-1800 VA: 45dBA @
1 meter
3000-6000 VA: 50dBA @ 1 meter |
|
Ambient Operating Temperature |
10 to 40oC (50 to
104oF) |
|
Ambient Storage Temperature |
-20 to 60oC (-4 to
140oF) |
|
Relative Humidity |
5-95% non-condensing |
|
EMI
Suppression |
600-1800 VA:
EN50081-1 EN50082-1
3000-6000 VA: FCC Part 15, sub part J Class A; CISPR Class A | | |