Eaton 9135 rack/tower UPS. 6000 VA / 4200W, 3U, 208V,
hardwired input, hardwired and (4) L6-30R output
| General |
| Topology |
Double-conversion |
| Catalog Number |
PW9135G6000-XL3UHW |
| Color |
Black |
| Rating (VA/Watts) |
6000/4200 |
| Diagnostics |
Full system self-test |
| Efficiency |
>97% in high-efficiency mode; 91% in normal mode |
| UPS Bypass |
Automatic bypass |
| Dimensions (H x W x D, inches) |
5.14 x 17.5 x 29.2 |
| Weight (lbs) |
125.7 |
| Warranty |
Two-year factory warranty |
| Rail Kit Included |
Included with all units |
Contents
(Ships with the following items) |
1 ready-to-go UPS
Software Suite CD
User Guide |
| Electrical Input |
| Connection |
Hardwired - see manual for terminal block layout |
| Nominal Voltage |
208 VAC |
| Frequency |
50/60 Hz autoselect |
| Frequency Range |
40–70 Hz |
| Nominal Current |
28.8 A |
| Power Draw of UPS |
5000 VA: 21.7A @230V 6000 VA: 26.0A @208V |
| Electrical Output |
| Output Receptacles |
(4)
L6-30R,
Hardwired - see manual for terminal block layout |
| On Utility Voltage Regulation |
±2% of nominal |
| On Battery Voltage Regulation |
±2% of nominal |
| Power Factor |
0.7 |
| Frequency Regulation |
±3% Hz online |
| Load Crest Factor |
3:1 |
| Battery |
| Maximum Number of Battery Packs |
4 |
| Battery Type |
(15) 12V, 5.5 Ah. Sealed, lead-acid; maintenance
free |
| Battery Runtime |
Four (4) minutes with internal batteries @100% load
(0.7 PF), For additional details, see battery runtime
chart |
| Half Load Runtime (in mins) |
10 |
| Full Load Runtime (in mins) |
4 |
| Start On Battery |
Allows start of UPS without utility input |
| Recharge Time |
Battery recharge time Six (6) hours to recover 90
percent of nominal backup time after 100 percent RCD
load discharge |
| Communications |
| User Interface |
Graphical LCD with blue backlight and text in
English, French, German, Portuguese, Italian and Spanish |
| LEDs |
Four status-indicating LEDs |
| Communication Ports |
Serial Port RS-232 as standard, RS-232 cable
provided ; USB Port As standard (HID), Relay output:
DB-9 Dry Contact (common alarm as standard) |
| Comunications Slot |
Optional communication slot (Mini X-Slot) |
| Power Management Software |
LanSafe UPS monitoring and management software |
| Environmental &
Standards |
| Heat Dissipation (BTU) |
Normal: 1350, Battery: 1960, High Efficiency: 450 |
| Audible Noise |
Max 46 dB |
| Operating Temperature |
0˚C (32˚F) to +40˚C (104˚F) |
| Safety markings |
UL, NOM, NYCE |
| EMC Markings |
FCC-A, VCCI-A, BSMI-A, C-Tick, CE Compliance |
| Storage Temperature |
-20˚C (-4˚F) to +40˚C (104˚F) with batteries and
-25˚C (-13˚F) to +55˚C (131˚F) without batteries |
| Relative Humidity |
5–90% non-condensing |
| Note: Due to continuing product
improvement programs, specifications are subject to
change without notice. |