Home • Up • MicroPod • Nfinity • Powersure Interactive • Powersure Personal • Powersure ProActive • PSP300 • PSP500 • UPStation_GTX_2U • UPStation GXT • UPStstion S • MicroPod • Nfinity • Powersure Interactive • Powersure Personal • Powersure ProActive • PSP300 • PSP500 • UPStation_GTX_2U • UPStation GXT • UPStstion S • MicroPod • Nfinity • Powersure Interactive • Powersure Personal • Powersure ProActive • PSP300 • PSP500 • UPStation_GTX_2U • UPStation GXT • UPStstion S

 

 

Contact Us Toll Free

Buy batteries on-line

Request Info

UPS Systems

Universal Battery Valve Regulated Lead Acid Batteries Batteries

  Emergency Lighting

Battery chargers, rectifiers, dc power systems by SENS Battery Chargers

Click for more about the Battery Rack™ 20 with Tester (Grey) Battery Storage

Specials!

Service

Lease Info

 

 

UPStation ® S

The Right Power Solution For Network

Liebert UPStation ® S Offers Power Protection For A Variety Of Applications:

bulletClusters Of Servers, Workstations, Peripherals, And                                                 Internet Devices
bulletRaid Arrays, Parallel Process Servers And Other                                                          Large-Scale Data Handling Systems
bulletLAN Gateways, Bridges, Routers, ATM, ISDN & Frame                                                        Relay Applications
bulletSuper-Servers, Mini-Computers And Multiprocessing                                                        Systems

Your Network Needs Power. You Need Power Over Your Network.

Utility Power Problems

Although utility power is almost always available, its quality is often inadequate for sensitive electronics. Inclement weather and downed service lines can cause short term problems. Long term quality problems are created by aging, overtaxed utility equipment, and by the changing needs of the devices using the power.

Your Network Has Power Problems

The distributed architecture of network computing actually makes your system more susceptible to power quality problems. In even the most conscientiously installed system, electrical noise and data errors can be transmitted to every node on the network. With the amount of stored data and work in process on a network, power problems are intolerable. Your network needs the reliable power quality and outage protection provided by an Uninterruptible Power Supply (UPS).

You Need Power Over Your Network

The nature of networks usually results in challenges to management, too. Significant physical distance and unstaffed sites are the norm. In a power outage, you need to verify operational status and control the operation of your network from a central location. To maximize battery time, you need to manage your computer load.

UPStation S UPS: Network Quality Power And Complete Operational Control

Liebert designed the UPStation S family of UPS to meet the demands of network computers. Available in eight models from 3.5 to 18 kVA, the UPStation S provides true on-line operation for the highest quality power to your load.

bulletLowest possible input power distortion eliminates electrical noise and harmonics concerns.
bulletPower conditioning minimizes potentially damaging power transients.
bulletWide input voltage range tolerates voltage fluctuations and deep brown outs without using the battery.
bulletFast, smooth transfer to battery during outages or out-of-tolerance conditions.
bulletIntegrated maintenance bypass capability on 3.5 to 6 kVA units provides even greater uptime for critical loads.

Communications features allow power control of connected network equipment from the front of the unit, or from a remote computer terminal with SNMP (Simple Network Management Protocol):

bulletRemote control of connected equipment.
bulletRemote monitoring of alarms and status information.
bulletRemote reset of individual network devices.
bulletPassword protection ensures security, prevents unauthorized                                    access to network.

In addition, UPStation S grows with your site needs. The standard unit is a compact, easily installed cabinet. By selecting an upgradeable model, you can expand your power capacity as your network grows. A wide variety of receptacle options allow you to customize units for your specific loads. Battery capacity may also be added, providing additional back-up time to match your needs.

Not Just Continuous Power... Continuous Quality Power

UPStation S assures you of reliable, continuous operation. But, it carries reliability even further...with standard features that provide quality power for the best possible network operation.

Isolation And Uninterrupted Transfer To Battery

bulletThe UPStation S Series’ True On-Line Design Means Isolation From Utility Aberrations, So Your Connected Equipment Receives Conditioned Power.
bulletThe High Frequency Isolation Transformer Within The UPStation S Minimizes Most Noise Present At The Input And Contributes To The Unit’s Small Footprint.
bulletTransfer To And From Battery Is Uninterrupted, So Your Load Is Never Vulnerable To UPS-To-Battery Switching Time.
bulletThe Wide Input Voltage Range (176-264 Volts) Helps The UPS Tolerate Utility Fluctuations And Deep Brown-Outs With Fewer Transfers To Battery For Extended Battery Life.
bulletBelow 176 Volts, The UPS Supplements Battery Power With The Utility Voltage, Thereby Extending Battery Run-Time.

Minimizes Computer-Generated Power Problems

bulletElectronic Equipment Is Notorious For                                                                     Causing Power Problems (Electrical Noise)                                                                     For Other Devices UPStream Or                                                                              Downstream On The Same Electrical                                                                           Circuit.
bulletThe S Series’ .98 Input Power Factor                                                                              Makes Optimal Use Of Utility Power.
bullet<5% Input Distortion Won’t Affect Other                                                                   Equipment On The Same Circuit,                                                                             Eliminating Electrical Noise And Harmonics                                                                   Concerns.
bulletDesigned To Work With Yesterday’s,                                                                       Today’s And Tomorrow’s Computers, The                                                                         UPStation S Supports 3:1 Crest Factor As                                                                         Well As Power-Factor Corrected                                                                       Computer Power Supplies.
bulletFiltered Bypass Provides Noise                                                                                   Suppression During Bypass Mode Plus Protection From Spikes During Service Mode.

 

 

Flexible Battery Back-Up... Add More Back-Up As Your Network Grows

Battery Reliability Before, During And After An Outage

bulletUPStation S Has Built-In System Features To Maximize Battery Reliability.
bulletBattery Availability Is Ensured With The Programmable Battery Test Which Automatically Checks Battery Viability At Intervals You Preselect.
bulletDuring Battery Discharge, You Are Continuously Apprised Of Remaining Battery Time.
bulletAfter Discharge, Temperature-Compensated Recharging Helps To Extend Battery Service Life By Putting Less Stress On The Batteries.

Extended UPS Protection

bulletLiebert’s UPStation S Extended Battery Cabinet Takes UPS Protection To A Higher Level.
bulletUPStation S Offers A Full Range Of Battery Back-Up Run Times, From 10 Minutes To 24 Hours.
bulletThe Extended Battery Cabinets With Chargers Include Their Own Ac To Dc Charger For A 24 Hour Recharge To 90% Capacity. This Fast Recharge Time Means That The Unit Is Quickly Ready To Support Your Loads After A Long Outage.

For greater battery reliability,
UPStation S can be preprogrammed
to test the battery at your selected interval.

The "Turbo" battery charging feature
provides safe, fast battery recharge
following a discharge, ensuring battery
availability when the battery is needed next.

 

Meet Your Exact Needs With Powerful, Versatile Customization Options

Stays Connected Even As You Grow

bulletThe S Series’ Modular Design Allows You To Adapt To                                                Changing Network Requirements So You Can Protect                                                  Your Investment.
bulletProgrammable Voltage And Frequency Enable The Unit                                                  To Adapt To Any Site.
bulletPower Capacity Can Be Upgraded As Your Needs                                                            Expand.
bulletAnd An Important Option For Many Networks: Easily                                                  Connected Battery Packs For Additional Battery Time.

Service UPStation S Without Interruption To Your Load

The Power Output Distribution (Pod™) Module Allows Hot Swap Capability For The 3.5 To 6 kVA Units, Providing Non-Interrupted Power To Your Equipment While The UPS Is Being Serviced Or The Batteries Replaced.

The Wall-Mountable UPStation S Maintenance Bypass Cabinets Provide Complete "Wrap-Around" Protection For 8-18 kVA Units.

Programmable Settings

The Menu-Driven LCD Display Lets You Monitor All Aspects Of The UPS, Plus It Allows You To Program Such Items As Low Battery alarm Set Point, Volume Of Audible Alarm, Auto Or Manual Restart And Many Others.

The POD TM enhances the UPStation’s plug-and-play convenience. A variety of receptacle options and maintenance bypass capability allow the 3.5-6 kVA UPS to be repaired or upgraded without interrupting power to your critical load. The LCD display is menu-driven for ease of use and provides complete metering and programmable control of UPS functions.

 

SNMP

Remote monitoring and control of UPStation S and your connected equipment is simplified with the optional internal SNMP (Simple Network Management Protocol) interface. Liebert has taken a leadership role in developing SNMP for Uninterruptible Power Supply systems. Unlike other UPS systems which "adapt" to SNMP with an external connection box, UPStation S was designed for SNMP communications, requiring only the addition of an internal card to be compatible with your network monitoring system. UPStation S is the only UPS in its category to offer internal SNMP for greatest reliability, less cost and simple connectivity.

bulletInternal installation saves space.
bulletSupported internally by the UPS. Others use external proxy adapters that require the use of a UPS receptacle or a separate UPS to maintain SNMP communication during a utility outage.
bulletInherently more reliable due to reduced external wiring, and no external box to mishandle or accidentally shut down.
bulletEthernet and Token Ring versions available.
bulletThis advanced technology allows you to monitor and control all network devices in a consistent manner, without special proprietary software.

Network Power Management

You can manage your network power at the local unit display panel, remotely with SNMP, or remotely with Liebert user-interface software.

Liebert’s unique Power Management feature allows pre-programmed start-up and shutdown routines for individual loads to remotely turn on and off loads when selected power conditions occur.

Remote UPStation S systems can communicate through a modem to your central monitor, or to Liebert Customer Service and Support (CS&S).

With the optional CS&S program, when there is a critical alarm, a service representative can be immediately dispatched to your site to get your system back on line as soon as possible.

Management Reporting

Updates of system operation, including battery time remaining, are easily accessed. An internal Event Log details the number of brown-outs, black-outs, and battery discharges. The Liebert UPStation family of UPS can play a powerful role in your network computer operations. UPStation S and UPStation GX (Rackmount or Tower configuration) work together to produce network-grade, on-line power protection for all sizes of network equipment, from 700 VA to 18 kVA. And the communications/control features are compatible for the entire UPStation family, allowing monitoring and control of all your important computing equipment.

Internal SNMP

bulletSNMP Capability Makes The Liebert UPS An Intelligent Network Peripheral.
bulletMonitoring Of Power Status From Any UPS In The Network
bulletCurrent Operating Status
bulletPower Conditions
bulletSystem Conditions
bulletAlarm Notification
bulletSNMP Traps Sent To Multiple Locations
bulletWarns Users Of Out-Of-Spec Conditions
bulletControl
bulletRemotely Reset Network Hardware
bulletRemotely Control UPS Operation

SiteNet SNMP Manager

bulletSnap-In Control And Monitoring Screens That Simplify UPS Monitoring With Your Network Management System.
bulletComplete Information In An Easy-To-Use Graphical User Interface
bulletUtility And UPS Power Status
bulletImmediate Notification Of Alarm Conditions
bulletEasy Installation
bulletAuto Set-Up At Time Of Installation
bulletA UPS Discovery Feature That Locates And Identifies Liebert UPSs On The Network

SiteNet SNMP Integrator

bulletAn External SNMP Module That Adds Environmental And Other Monitoring Capability To The UPS SNMP.
bulletConnections For Two Temperature And Humidity Sensors
bullet10 Digital Inputs With Trap Notification
bulletLocal Audible And Visual Alarm
bulletTwo Power Sources Provide On/Off Switching

Two Contact Closure Outputs

Power-Packed Network Protection For Today’s Needs & Tomorrow’s Growth

 

UPStation S

Power Rating
a

3.5 kVA/
2.8 kW

4.5 kVA/
3.6 kW

6.0 kVA/
4.0 kW

8.0 kVA/
6.0 kW

10.0 kVA/
7.5 kW

12.0 kVA/
8.4 kW

15.0 kVA/
10.5 kW

18.0 kVA/
12.6 kW

Input
Voltage Range
Frequency
Input Current THD
Power Factor

a
176-264V
50 or 60 Hz
<5% maximum
.98 minimum

Output
Voltage (L-L, L-N)
Voltage Regulation
Overload

a
200/100V, 208/120V, 220/110, 220/127V, 230/115V, 240/120V, 220V L-N, 240V L-N
±2%
150% for 10 seconds; 125% for 10 minutes

Battery
Run Time (min.)
(Half load/Full load)
Recharge Time

a
(37/18)             (29/12)               (25/11)               (35/17)              (28/11)              (24/10)              (32/14)              (27/10)
a
10 times the discharge time to 95% capacity

Communications
a

SiteNet 1 Shutdown Interface SiteNet 2 Monitoring Software
SiteNet SNMP-Software SiteNet Integrator

Agency Approvals
Safety
Emissions/Surge

a
UL 1778, CSA
FCC Part 15, Subpart J, Class A, IEEE 587/ANSI C62.41 Category A & B

Physical
Audible Noise
Operating Environ.
Dimensions
HxWxD

a
<55 dBA at one meter
0 to 40 degrees C, 0-95% relative humidity, non-condensing
                29x9x31"                                                        29x18x27"                                            29x27x27"
            735mm x 230mm x 685mm                              735mm x 460mm x 685mm            735mm x 685mm x 685mm

Weight (with standard batt.)

270 lbs (123 kg)
a

560 lbs (254 kg)
a

780 lbs (354 kg)
a

 

Warranty & UPSize Programs Support Your Needs Today...And Tomorrow

Liebert’s Standard One-Year Warranty Ensures Repair Or Replacement Of Your UPS If It Experiences Problems During The Warranty Period. Liebert’s Customer Service And Support Organization Provides The Most Comprehensive On-Site UPS Support In The Industry.

Liebert’s $25,000 Product Protection Promise Provides Repair Costs Or Reimbursements Up To $25,000 If Your UPStation S Rated At 6kva Or Less Fails To Protect Your Connected Equipment From Damage Caused By Incoming Power Line Transients.

Liebert’s Warranty Extension Program allows you to add up to three years to your original warranty... up to five years of full warranty protection. Finally, Liebert provides technical support as long as you own a Liebert UPS. A call to 1-800-222-5877 puts you in touch with an experienced technical support specialist.

The Liebert Support System: On Call 24 Hours A Day, 365 Days A Year To Ensure Continuous Uptime For Your System

Liebert UPS Maintenance

Liebert Customer Service Has A Series Of Programs Specifically Designed To Support UPS Systems For Distributed Processing Applications. These Include:

Start-Up
Liebert Will Perform A Thorough And Efficient Start-Up For Your New UPS In Order To Ensure The Reliable And Safe Operation Of New Equipment.

Emergency Services
Liebert Provides Its Customers With An Around-The-Clock Hotline. Your Call Triggers An Immediate Response To Emergency And Disaster Situations, And Total Satisfaction Package Support.

Preventive/Scheduled Maintenance
Liebert’s Preventive Maintenance Programs Include Complete Electrical Checkout And Calibration To Specifications. Service Team Members Can Also Field-Install Upgrades And Enhancements As Part Of The Maintenance Program.

Battery Maintenance & Management
In Accordance With IEEE And Manufacturer Specifications, Liebert Takes Direct Responsibility For Performing Corrective Battery Maintenance, Battery Replacement, Impedance Testing And Battery Inspections. This Optional Program Also Includes A Customer Report Complete With Recommendations And Action Plans For Enhancing UPS Performance And Reliability.

Customer Training
Liebert Will Conduct Professional Training Sessions That Are Certified By Many Professional Organizations. Training Subjects Cover Specific UPS Systems And A Wide Variety Of Product Applications. Classes Can Be Held At Liebert Or At A Customer Site.

Power Analysis
Liebert — The Acknowledged Power Protection Experts For Three Decades — Can Help You Identify And Correct Specific Power Problems. Liebert Can Also Research And Develop A Strategic Analysis And Recommendations For Power Protection That Will Keep Pace With The Often Explosive Growth Of Distributed Processing Networks.

Liebert: A Clear Path To The Future
Since its founding in 1965, Liebert has led the market in computer protection systems. From this history— millions of hours of failure-free operation— Liebert has developed a complete range of support and protection systems for sensitive electronics used in a wide range of applications from mainframe to personal computers, from process control to laboratories, and from telecommunication to medical imaging:

Environmental Control. Ceiling-mounted units for small rooms and spot protection, up to 30-ton redundant models for the traditional glass house. Includes hardened systems for aggressive industrial atmospheres.

Power Conditioning and UPS (Uninterruptible Power Supply) systems. Solutions for whole facilities, large mainframes with associated peripherals, right on down to desktop PCs.

DataPad®. Cooling, power conditioning, and UPS backup, along with cabling and distribution capability in a modular raised platform design. For mid-size computers and large system servers.

Little Glass House. Cooling, power conditioning, and UPS backup in a secure, compact cabinet for distributed processing centers.

Real-time monitoring and control of sprawling computer and control systems from a single or multiple locations, on-site or remote.

 

Home - 9 Power Problems - Problems with Power - APC - Powerware - MinuteMan - MGE - Liebert - Batteries - Chargers / Rectifiers - Emergency Lighting - Service - Factory Links

 Contact Us

Power Factor Inc.

2526 Manana Dr – Suite 102 – Dallas – Texas – 75220

NO DISSATISFIED CUSTOMERS!

Since 1995

While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.