UPStation ® S
The Right Power Solution For Network

Liebert UPStation ® S Offers Power Protection For A Variety Of Applications:
 | Clusters Of Servers, Workstations, Peripherals, And
Internet Devices |
 | Raid Arrays, Parallel Process Servers And Other
Large-Scale Data Handling Systems |
 | LAN Gateways, Bridges, Routers, ATM, ISDN & Frame
Relay Applications |
 | Super-Servers, Mini-Computers And Multiprocessing
Systems |
Your Network Needs Power. You Need Power Over Your Network.
Utility Power Problems
Although utility power is almost always available, its quality is often
inadequate for sensitive electronics. Inclement weather and downed service lines
can cause short term problems. Long term quality problems are created by aging,
overtaxed utility equipment, and by the changing needs of the devices using the
power.
Your Network Has Power Problems
The distributed architecture of network computing actually makes your system
more susceptible to power quality problems. In even the most conscientiously
installed system, electrical noise and data errors can be transmitted to every
node on the network. With the amount of stored data and work in process on a
network, power problems are intolerable. Your network needs the reliable power
quality and outage protection provided by an Uninterruptible Power Supply (UPS).
You Need Power Over Your Network
The nature of networks usually results in challenges to management, too.
Significant physical distance and unstaffed sites are the norm. In a power
outage, you need to verify operational status and control the operation of your
network from a central location. To maximize battery time, you need to manage
your computer load.
UPStation S
UPS: Network Quality Power And Complete Operational Control
Liebert designed the UPStation S family of UPS to meet the demands of network
computers. Available in eight models from 3.5 to 18 kVA, the UPStation S
provides true on-line operation for the highest quality power to your load.
 | Lowest possible input power distortion eliminates electrical noise and
harmonics concerns. |
 | Power conditioning minimizes potentially damaging power transients. |
 | Wide input voltage range tolerates voltage fluctuations and deep brown
outs without using the battery. |
 | Fast, smooth transfer to battery during outages or out-of-tolerance
conditions. |
 | Integrated maintenance bypass capability on 3.5 to 6 kVA units provides
even greater uptime for critical loads. |
Communications
features allow power control of connected network equipment from the front of
the unit, or from a remote computer terminal with SNMP (Simple Network
Management Protocol):
 | Remote control of connected equipment. |
 | Remote monitoring of alarms and status information. |
 | Remote reset of individual network devices. |
 | Password protection ensures security, prevents unauthorized
access to network. |
In addition, UPStation S grows with your site needs. The standard unit is a
compact, easily installed cabinet. By selecting an upgradeable model, you can
expand your power capacity as your network grows. A wide variety of receptacle
options allow you to customize units for your specific loads. Battery capacity
may also be added, providing additional back-up time to match your needs.
Not Just Continuous Power... Continuous Quality Power
UPStation S assures you of reliable, continuous operation. But, it carries
reliability even further...with standard features that provide quality power for
the best possible network operation.
Isolation And Uninterrupted Transfer To Battery
 | The UPStation S Series’ True On-Line Design Means Isolation From Utility
Aberrations, So Your Connected Equipment Receives Conditioned Power. |
 | The High Frequency Isolation Transformer Within The UPStation S Minimizes
Most Noise Present At The Input And Contributes To The Unit’s Small Footprint.
|
 | Transfer To And From Battery Is Uninterrupted, So Your Load Is Never
Vulnerable To UPS-To-Battery Switching Time. |
 | The Wide Input Voltage Range (176-264 Volts) Helps The UPS Tolerate
Utility Fluctuations And Deep Brown-Outs With Fewer Transfers To Battery For
Extended Battery Life. |
 | Below 176 Volts, The UPS Supplements Battery Power With The Utility
Voltage, Thereby Extending Battery Run-Time. |
Minimizes
Computer-Generated Power Problems
 | Electronic Equipment Is Notorious For
Causing Power Problems (Electrical Noise)
For Other Devices UPStream Or
Downstream On The Same Electrical Circuit.
|
 | The S Series’ .98 Input Power Factor
Makes Optimal Use Of Utility Power. |
 | <5% Input Distortion Won’t Affect Other
Equipment On The Same Circuit,
Eliminating Electrical Noise And Harmonics
Concerns. |
 | Designed To Work With Yesterday’s,
Today’s And Tomorrow’s Computers, The
UPStation S Supports 3:1 Crest Factor As
Well As Power-Factor Corrected
Computer Power Supplies. |
 | Filtered Bypass Provides Noise
Suppression During Bypass Mode Plus Protection From Spikes During Service
Mode. |
Flexible Battery Back-Up... Add More Back-Up As Your Network Grows
Battery Reliability Before, During And After An Outage
 | UPStation S Has Built-In System Features To Maximize Battery Reliability.
|
 | Battery Availability Is Ensured With The Programmable Battery Test Which
Automatically Checks Battery Viability At Intervals You Preselect. |
 | During Battery Discharge, You Are Continuously Apprised Of Remaining
Battery Time. |
 | After Discharge, Temperature-Compensated Recharging Helps To Extend
Battery Service Life By Putting Less Stress On The Batteries. |
Extended UPS Protection
 | Liebert’s UPStation S Extended Battery Cabinet Takes UPS Protection To A
Higher Level. |
 | UPStation S Offers A Full Range Of Battery Back-Up Run Times, From 10
Minutes To 24 Hours. |
 | The Extended Battery Cabinets With Chargers Include Their Own Ac To Dc
Charger For A 24 Hour Recharge To 90% Capacity. This Fast Recharge Time Means
That The Unit Is Quickly Ready To Support Your Loads After A Long Outage. |
 |
 |
|
For greater battery reliability,
UPStation S can be preprogrammed
to test the battery at your selected interval. |
The "Turbo" battery charging feature
provides safe, fast battery recharge
following a discharge, ensuring battery
availability when the battery is needed next. |

Meet Your
Exact Needs With Powerful, Versatile Customization Options
Stays Connected Even As You Grow
 | The S Series’ Modular Design Allows You To Adapt To
Changing Network Requirements So You Can Protect
Your Investment. |
 | Programmable Voltage And Frequency Enable The Unit
To Adapt To Any Site. |
 | Power Capacity Can Be Upgraded As Your Needs
Expand. |
 | And An Important Option For Many Networks: Easily
Connected Battery Packs For Additional Battery Time. |
Service UPStation S Without Interruption To Your Load
The Power Output Distribution (Pod™) Module Allows Hot Swap Capability For
The 3.5 To 6 kVA Units, Providing Non-Interrupted Power To Your Equipment While
The UPS Is Being Serviced Or The Batteries Replaced.
The Wall-Mountable UPStation S Maintenance Bypass Cabinets Provide Complete
"Wrap-Around" Protection For 8-18 kVA Units.
Programmable Settings
The Menu-Driven LCD Display Lets You Monitor All Aspects Of The UPS, Plus It
Allows You To Program Such Items As Low Battery alarm Set Point, Volume Of
Audible Alarm, Auto Or Manual Restart And Many Others.
The POD TM
enhances the UPStation’s plug-and-play convenience. A variety of
receptacle options and maintenance bypass capability allow the 3.5-6 kVA
UPS to be repaired or upgraded without interrupting power to your critical
load. |
The LCD
display is menu-driven for ease of use and provides complete metering and
programmable control of UPS functions. |
SNMP
Remote monitoring and control of UPStation S and your connected equipment is
simplified with the optional internal SNMP (Simple Network Management Protocol)
interface. Liebert has taken a leadership role in developing SNMP for
Uninterruptible Power Supply systems. Unlike other UPS systems which "adapt" to
SNMP with an external connection box, UPStation S was designed for SNMP
communications, requiring only the addition of an internal card to be compatible
with your network monitoring system. UPStation S is the only UPS in its category
to offer internal SNMP for greatest reliability, less cost and simple
connectivity.
 | Internal installation saves space. |
 | Supported internally by the UPS. Others use external proxy adapters that
require the use of a UPS receptacle or a separate UPS to maintain SNMP
communication during a utility outage. |
 | Inherently more reliable due to reduced external wiring, and no external
box to mishandle or accidentally shut down. |
 | Ethernet and Token Ring versions available. |
 | This advanced technology allows you to monitor and control all network
devices in a consistent manner, without special proprietary software. |
Network Power Management
You can manage your network power at the local unit display panel, remotely
with SNMP, or remotely with Liebert user-interface software.
Liebert’s unique Power Management feature allows pre-programmed start-up and
shutdown routines for individual loads to remotely turn on and off loads
when selected power conditions occur.
Remote UPStation S systems can communicate through a modem to your central
monitor, or to Liebert Customer Service and Support (CS&S).
With the optional CS&S program, when there is a critical alarm, a service
representative can be immediately dispatched to your site to get your system
back on line as soon as possible.
Management Reporting
Updates of system operation, including battery time remaining, are easily
accessed. An internal Event Log details the number of brown-outs, black-outs,
and battery discharges. The Liebert UPStation family of UPS can play a powerful
role in your network computer operations. UPStation S and UPStation GX (Rackmount
or Tower configuration) work together to produce network-grade, on-line power
protection for all sizes of network equipment, from 700 VA to 18 kVA. And the
communications/control features are compatible for the entire UPStation family,
allowing monitoring and control of all your important computing equipment.

Internal SNMP
 | SNMP Capability Makes The Liebert UPS An Intelligent Network Peripheral.
|
 | Monitoring Of Power Status From Any UPS In The Network |
 | Current Operating Status |
 | Power Conditions |
 | System Conditions |
 | Alarm Notification |
 | SNMP Traps Sent To Multiple Locations |
 | Warns Users Of Out-Of-Spec Conditions |
 | Control |
 | Remotely Reset Network Hardware |
 | Remotely Control UPS Operation |
SiteNet SNMP Manager
 | Snap-In Control And Monitoring Screens That Simplify UPS Monitoring With
Your Network Management System. |
 | Complete Information In An Easy-To-Use Graphical User Interface |
 | Utility And UPS Power Status |
 | Immediate Notification Of Alarm Conditions |
 | Easy Installation |
 | Auto Set-Up At Time Of Installation |
 | A UPS Discovery Feature That Locates And Identifies Liebert UPSs On The
Network |
SiteNet SNMP Integrator
 | An External SNMP Module That Adds Environmental And Other Monitoring
Capability To The UPS SNMP. |
 | Connections For Two Temperature And Humidity Sensors |
 | 10 Digital Inputs With Trap Notification |
 | Local Audible And Visual Alarm |
 | Two Power Sources Provide On/Off Switching |
Two Contact Closure Outputs

Power-Packed Network Protection For Today’s Needs & Tomorrow’s Growth
|
UPStation S |
|
Power Rating
a |
3.5 kVA/
2.8 kW |
4.5 kVA/
3.6 kW |
6.0 kVA/
4.0 kW |
8.0 kVA/
6.0 kW |
10.0 kVA/
7.5 kW |
12.0 kVA/
8.4 kW |
15.0 kVA/
10.5 kW |
18.0 kVA/
12.6 kW |
|
Input
Voltage Range
Frequency
Input Current THD
Power Factor |
a
176-264V
50 or 60 Hz
<5% maximum
.98 minimum |
|
Output
Voltage (L-L, L-N)
Voltage Regulation
Overload |
a
200/100V, 208/120V, 220/110,
220/127V, 230/115V, 240/120V, 220V L-N, 240V L-N
±2%
150% for 10 seconds; 125% for 10 minutes |
|
Battery
Run Time (min.)
(Half load/Full load)
Recharge Time |
a
(37/18) (29/12) (25/11)
(35/17) (28/11) (24/10)
(32/14) (27/10)
a
10 times the discharge time to 95% capacity |
|
Communications
a |
SiteNet 1 Shutdown Interface SiteNet 2 Monitoring Software
SiteNet SNMP-Software SiteNet Integrator |
|
Agency Approvals
Safety
Emissions/Surge |
a
UL 1778, CSA
FCC Part 15, Subpart J, Class A, IEEE 587/ANSI C62.41 Category A & B |
|
Physical
Audible Noise
Operating Environ.
Dimensions
HxWxD |
a
<55 dBA at one meter
0 to 40 degrees C, 0-95% relative humidity, non-condensing
29x9x31"
29x18x27" 29x27x27"
735mm x 230mm x 685mm 735mm x 460mm
x 685mm 735mm x 685mm x 685mm |
|
Weight (with standard batt.) |
270 lbs (123 kg)
a |
560 lbs (254 kg)
a |
780 lbs (354 kg)
a |
Warranty & UPSize Programs Support Your Needs Today...And Tomorrow
Liebert’s Standard One-Year Warranty Ensures Repair Or Replacement Of
Your UPS If It Experiences Problems During The Warranty Period. Liebert’s
Customer Service And Support Organization Provides The Most Comprehensive
On-Site UPS Support In The Industry.
Liebert’s $25,000 Product Protection Promise Provides Repair Costs Or
Reimbursements Up To $25,000 If Your UPStation S Rated At 6kva Or Less Fails To
Protect Your Connected Equipment From Damage Caused By Incoming Power Line
Transients.
Liebert’s Warranty Extension Program allows you to add up to three
years to your original warranty... up to five years of full warranty protection.
Finally, Liebert provides technical support as long as you own a Liebert UPS. A
call to 1-800-222-5877 puts you in touch with an experienced technical
support specialist.
The Liebert Support System: On Call 24 Hours A Day, 365 Days A Year
To Ensure Continuous Uptime For Your System
Liebert UPS Maintenance
Liebert Customer Service Has A Series Of Programs Specifically Designed To
Support UPS Systems For Distributed Processing Applications. These Include:
Start-Up
Liebert Will Perform A Thorough And Efficient Start-Up For Your New UPS
In Order To Ensure The Reliable And Safe Operation Of New Equipment.
Emergency Services
Liebert Provides Its Customers With An Around-The-Clock Hotline. Your
Call Triggers An Immediate Response To Emergency And Disaster Situations, And
Total Satisfaction Package Support.
Preventive/Scheduled Maintenance
Liebert’s Preventive Maintenance Programs Include Complete Electrical
Checkout And Calibration To Specifications. Service Team Members Can Also
Field-Install Upgrades And Enhancements As Part Of The Maintenance Program.
Battery Maintenance & Management
In Accordance With IEEE And Manufacturer Specifications, Liebert Takes
Direct Responsibility For Performing Corrective Battery Maintenance, Battery
Replacement, Impedance Testing And Battery Inspections. This Optional Program
Also Includes A Customer Report Complete With Recommendations And Action Plans
For Enhancing UPS Performance And Reliability.
Customer Training
Liebert Will Conduct Professional Training Sessions That Are Certified
By Many Professional Organizations. Training Subjects Cover Specific UPS Systems
And A Wide Variety Of Product Applications. Classes Can Be Held At Liebert Or At
A Customer Site.
Power Analysis
Liebert — The Acknowledged Power Protection Experts For Three Decades —
Can Help You Identify And Correct Specific Power Problems. Liebert Can Also
Research And Develop A Strategic Analysis And Recommendations For Power
Protection That Will Keep Pace With The Often Explosive Growth Of Distributed
Processing Networks.
Liebert: A Clear Path To The Future
Since its founding in 1965, Liebert has led the market in computer
protection systems. From this history— millions of hours of failure-free
operation— Liebert has developed a complete range of support and protection
systems for sensitive electronics used in a wide range of applications from
mainframe to personal computers, from process control to laboratories, and from
telecommunication to medical imaging:
Environmental Control. Ceiling-mounted units for small rooms and spot
protection, up to 30-ton redundant models for the traditional glass house.
Includes hardened systems for aggressive industrial atmospheres.
Power Conditioning and UPS (Uninterruptible Power Supply) systems.
Solutions for whole facilities, large mainframes with associated peripherals,
right on down to desktop PCs.
DataPad®. Cooling, power conditioning, and UPS backup, along
with cabling and distribution capability in a modular raised platform design.
For mid-size computers and large system servers.
Little Glass House™. Cooling, power conditioning, and UPS
backup in a secure, compact cabinet for distributed processing centers.
Real-time monitoring and control of sprawling computer and control
systems from a single or multiple locations, on-site or remote.
|