Back Up Next Home Batteries  UPS Technology Emergency Lighting Battery Chargers Factory Links Contact Us Buy Batteries Online

Established 1996                              Call us 800-706-7009

.
Home GE Digital Energy LPC Powerware MGE Liebert MinuteMan ONEAC White Papers Remote Monitoring

.

 

Click here to Buy batteries online

Batteries
UPS Technology
Emergency Lighting
Battery Chargers
TVSS
9 Power Problems
Problems with Power
Factory Links
Contact Us

MicroPod
Nfinity
Powersure Interactive
Powersure Personal
Powersure ProActive
UPStation_GTX_2U
UPStation GXT
UPStstion S

Please Call 800-706-7009 or click here for price and availability.

Reliance on sensitive electronic equipment is at an all time high - so is the cost of downtime. When your critical systems demand reliable power protection, the UPStation¨ GXT delivers the power backup and conditioning you need.

 

The UPStation GXT 6 and 10 kVA units offer true on-line power protection able to protect large groups of critical equipment and theability to keep pace with your growing power protection needs.

 

The GXT features easy to operate controls, slide-in communications options, and simple installation and battery upgrades.

 

But simplicity is only the start...on line design means superior power quality even under the worst conditions: sags, surges, even frequency deviations. And as with all Liebert power equipment, a Liebert representative or VAR is close by to help with technical and application questions.

  • True On-Line Design
  • Protection Against All Power Threats
  • Internal SNMP Communications and Other Monitoring Options
  • Extended Battery Options
  • Standard Two-Year Warranty


      
 

 

Ideal Applications:

 

  • Clusters of workstations, peripherals and internet devices
     
  • RAID arrays, parallel process servers and other large-scale data handling systems
     
  • LAN gateways, bridges, routers, ATM, ISDN & frame relay applications
     
  • Auper-servers, mini-computers and multiprocessing systems
     

 

It is more important than ever to find a UPS solution that is equipped to handle virtually any power problem. It means finding a system that fits in -- and communicates with -- the equipment it is protecting. And above all, it means selecting a UPS that can handle a wide range of power inputs and still supply clean, precise power for your vital systems.

 

UPStation® GXT
With the Liebert UPStation® GXT, your equipment is protected by a proven, reliable UPS solution that meets the challenges presented by the protected equipment, the power supply, and the sophisticated user.

 

  • On-Line Protection for Critical Equipment. UPStation® GXT is designed to address the power problems that commonly threaten networks and other critical equipment. Surges, sags, outages, generator operation, and other power anomolies are handle easily by UPStation® GXT.

     

  • Flexible Battery Back-Up. Liebert's rapid recharge system helps override multiple outages with its quick recovery. Additional battery capacity can extend your blackout override period.

     

  • Communications For Power Monitoring and Control. The UPStation® GXT offers a variety of UPS communications, including SNMP-based options, to provide the monitoring capabilities demanded by today's network computing systems.

     

  • Warranty Support You Can Count On. Liebert's standard two-year warranty ensures repair or replacement of your UPS if it experiences problems during the warranty period.

     

  • Ongoing Technical Support. We provide you with technical support for as long as you own a Liebert UPS. A call to 1-800-222-5877 puts you in touch with an experienced UPS specialist. (614-841-6755 outside the U.S.)

     

  • $25,000 Product Protection Promise. Liebert will provide repair costs or reimbursement up to $25,000 if your UPStation® GXT fails to protect your connected equipment from damage caused by incoming AC power line transfers.

     

 
Power Handling
A true on-line UPS, the UPStation® GXT is inherently superior for protecting against the damaging effects of imperfect power:

 

  • Power spikes and transients. Surge protection capability meets IEEE 587 Category A, IEC 801-2 Level 4, IEC 801-3 Level 3, IEC 801-4 Level 4 and IEC 801-5 Level 3.

     

  • EMI/RFI noise reduction. Full-time EMI/RFI filtering improves computer performance and helps eliminate minor data corruption and noise-induced glitches that generate most problems.

     

  • Voltage sags and brownout conditions. UPStation® GXT has one of the widest input voltage ranges available, so minor low voltage conditions are corrected without resorting to battery operation. The input voltage is variable, based upon output load levels. These may drop as much as 50% below normal before transfer to back-up, reducing the number of battery discharges and extending service life.

     

  • Harmonics. A special category of noise that causes waveform distortion, harmonics can be triggered by problems hundreds of miles away or as near as the next piece of equipment on the network. Because they are difficult to find and correct, harmonics are best reduced at the UPS. Not all UPS systems can do that -- the UPStation¨ GXT can.

     

  • Power factor corrected loads. Computer equipment can cause voltage oscillations and adversely affect devices throughout the network. The Upstation® GXT maintains stable voltage output even with the power-factor corrected loads typical of modern computer equipment.

     

  • Outages. With the zero transfer time offered by on-line technology, flexible battery configurations and the ability to handle generator-produced power, your network won't even blink during an extended outage.

     

 

Battery Operation

The UPStation® GXT features unexcelled battery flexibility. It can be configured according to your site needs and type of application. The standard UPStation® GXT provides five to ten minutes of back-up power at full load. That's longer than 98% of all power outages and enough time to shut down critical operations in an orderly fashion.

 

  • Zero Transfer Time. When utility power fails, your critical load remains supported by a seamless flow of power from the UPStation® GXT. True on-line design means zero transfer time from external to internal power.

     

  • Maintenance-Free Batteries. The UPStation® GXT uses sealed, valve-regulated, lead-acid batteries, to provide long, trouble-free service life.

     

  • Add-On Battery Cabinets. Additional battery cabinets can be added to provide additional runtime as your needs change.

     

Integrated Monitoring and Control

The front panel of the UPS provides system status, load levels, battery capacity remaining and any alarm conditions. It also shows an indication and diagnosis of UPS fault conditions.

 

 

  Communications Hardware and
Software Options

The UPStation® GXT provides the communications capability and flexibility that is vital to the continuous operation of today's more complex distributed computing systems.

 

  • Intellislot SNMP. The UPStation® GXT offers internal SNMP, providing communications simplicity not available in an external SNMP device. SNMP allows monitoring and control of all network devices in a consistent manner. Internal SNMP installation also saves space, enhances reliability, and is internally protected by the UPS. This is an invaluable monitoring and control system for networks operating on this industry standard.
     

 

 

  • SiteNet® SNMP Manager. UPS monitoring software for Network Management Systems is a series of snap-in screens for your NMS software. This easy-to-use software seamlessly incorporates your Liebert UPS into your network and provides user-friendly monitoring and control of power.

     

  • SiteNet® 1. UPS shutdown software prevents unexpected server shutdown by automatically monitoring UPS activity and closing down protected nodes if utility power remains off.

     

  • MultiPort 8 and MultiPort 4. When used in conjunction with SiteNet® software, the external SiteNet® MultiPort multiplexer communicates the status of a single UPS to as many as eight PCs, servers or workstations. When installed in the UPStation¨ GXT Intellislot, the MultiPort 4 allows communication to up to four PCs, servers or workstations.

     

  • SiteNet® MultiLink. Multi-platform software allows monitoring of UPS status, with automatic orderly shutdown of a single computer or a network of servers. Download this free software from www.liebert.com.

     

UPStation® GXT 6kVA
Model No. GXT6000T-230 GXT6000T-230X GXT6000T-208 GXT6000T-208X GXT6000T-240X
VA (max.) 6000 6000 5400 5400 6000
Watts (max.) 4200 4200 3780 3780 4200
Input Voltage Range 230 VAC nominal; variable based upon output load 230 VAC nominal; variable based upon output load 208 VAC nominal; variable based upon output load 208 VAC nominal; variable based upon output load 240 VAC nominal; variable based upon output load
100%-90% Loading 186 VAC to 280 VAC; +/- 5%
89%-70% Loading 159 VAC to 280 VAC; +/- 5%
69%-30% Loading 139 VAC to 280 VAC; +/- 5%
29%-0% Loading 119 VAC to 280 VAC; +/- 5%
Input Connection Terminal Block (hardwired)
Output Voltage Range 230 VAC; +/- 3% 230 VAC; +/- 7% 208 VAC; +/- 3% 208/120 VAC; +/- 7% 240/120 VAC; +/- 7%
Output Waveform Sinewave
Output Connection Terminal Block (hardwired)
Battery Time (FL/HL) 7 min./18 min.
Agency Approvals TUV / CE UL / c-UL
Dimensions: mm (in.)
W x D x H
260 x 588 x 800 (10.25 x 22.0 x 31.5) 260 x 588 x 800 (10.25 x 22.0 x 31.5) 260 x 588 x 800 (10.25 x 22.0 x 31.5) 260 x 588 x 800 (10.25 x 22.0 x 31.5) 260 x 588 x 800 (10.25 x 22.0 x 31.5)
Weight: kg (lbs.) 99 (218) 139 (306) 99 (218) 139 (306) 139 (306)

 

UPStation® GXT 10kVA
Model No. GXT10000T-230 GXT10000T-230X GXT10000T-208 GXT10000T-208X GXT10000T-240X
VA (max.) 10000 10000 9000 9000 10000
Watts (max.) 7000 7000 6300 6300 7000
Input Voltage Range 230 VAC nominal; variable based upon output load 230 VAC nominal; variable based upon output load 208 VAC nominal; variable based upon output load 208 VAC nominal; variable based upon output load 240 VAC nominal; variable based upon output load
100%-90% Loading 186 VAC to 280 VAC; +/- 5%
89%-70% Loading 159 VAC to 280 VAC; +/- 5%
69%-30% Loading 139 VAC to 280 VAC; +/- 5%
29%-0% Loading 119 VAC to 280 VAC; +/- 5%
Input Connection Terminal Block (hardwired)
Output Voltage Range 230 VAC; +/- 3% 230 VAC; +/- 7% 208 VAC; +/- 3% 208/120 VAC; +/- 7% 240/120 VAC; +/- 7%
Output Waveform Sinewave
Output Connection Terminal Block (hardwired)
Battery Time (FL/HL) 10 min./25 min.
Agency Approvals TUV / CE UL / c-UL
Dimensions: mm (in.)
W x D x H
340 x 640 x 965 (13.4 x 25.25 x 38.0) 340 x 640 x 965 (13.4 x 25.25 x 38.0) 340 x 640 x 965 (13.4 x 25.25 x 38.0) 340 x 640 x 965 (13.4 x 25.25 x 38.0) 340 x 640 x 965 (13.4 x 25.25 x 38.0)
Weight: kg (lbs.) 187 (412) 244 (538) 187 (412) 244 (538) 244 (538)

Note: Models with an "X" suffix contain isolation transformers. Specifications subject to change without notice.
 

 

Home Batteries  UPS Technology Emergency Lighting Battery Chargers Factory Links Contact Us Buy Batteries Online

Power Factor Inc.

2526 Manana Dr – Suite 102 – Dallas – Texas – 75220

800-706-7009

 Our Goal, NO DISSATISFIED CUSTOMERS!

Since 1995

While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.