Home • Up • MicroPod • Nfinity • Powersure Interactive • Powersure Personal • Powersure ProActive • PSP300 • PSP500 • UPStation_GTX_2U • UPStation GXT • UPStstion S • MicroPod • Nfinity • Powersure Interactive • Powersure Personal • Powersure ProActive • PSP300 • PSP500 • UPStation_GTX_2U • UPStation GXT • UPStstion S • MicroPod • Nfinity • Powersure Interactive • Powersure Personal • Powersure ProActive • PSP300 • PSP500 • UPStation_GTX_2U • UPStation GXT • UPStstion S

 

 

Contact Us Toll Free

Buy batteries on-line

Request Info

UPS Systems

Universal Battery Valve Regulated Lead Acid Batteries Batteries

  Emergency Lighting

Battery chargers, rectifiers, dc power systems by SENS Battery Chargers

Click for more about the Battery Rack™ 20 with Tester (Grey) Battery Storage

Specials!

Service

Lease Info

 

 

UPStation GXT 2U - 60Hz
Product Description

 

 

The New Shape of Network Power Protection

The GXT 2U takes the outstanding features and unmatched reliability of our UPStation GXT series and puts it into a smaller 2U size cabinet. A true on-line UPS, GXT 2U includes power factor correction, internal batteries, frequency conversion, unlimited external battery connectability, and internal automatic / manual bypass capability. For maximum flexibility, the GXT 2U can be installed as a space-saving rack-mounted unit or a space-saving, free standing tower. A Windows® software program is included that allows the user to custom configure the GXT 2U to meet one's individual needs. The UPStation GXT 2U - all the right features, just the right size.

Features:

bulletTVSS standard
bulletUser replaceable batteries without removing GXT 2U from rack
bulletSNMPE3 compatiable
bulletCompatiable with Intellislot SNMP/Web Card
bulletCompatiable with AS400 Card (relay contacts)
bulletStandard two-year warranty
 
  The Liebert GXT 2U UPS system takes the outstanding features and unmatched reliability of Liebert's UPStation GXT series--and puts it all into a smaller 2U size cabinet. As a true on-line UPS, GXT 2U includes power factor correction, internal batteries, frequency conversion, unlimited external battery connectability, and internal automatic and manual bypass capability.
 

The Liebert GXT 2U is designed with the features you need to protect mission-critical equipment from a variety of power problems:

 
  • True on-line design
  • Wide input voltage window allows UPS support without going to battery, extending systems availability
  • TVSS standard
  • User replaceable batteries without removing GXT 2U from rack
  • SNMPE3 compatible
  • Compatible with Intellislot SNMP/Web Card
  •  
     
  • Compatible with Multiport4 or 8
  • Compatible with AS400 Card (relay contacts)
  • Compatible with MultiLink, SiteNet 1
  • External plug and play, 2U battery cabinets available
  • Standard two-year warranty
  • Configurable as rack or tower
  •  
      

     

      On-line design means zero transfer time from external to internal power. When utility power fails, your critical load remains supported by a seamless flow of power from the GXT 2U.

    For maximum control, the GXT 2U is custom configurable to your needs using a specially designed Windows software package. Offered in 700, 1000, 1500, 2000 and 3000 VA capacities, the GXT 2U also provides easy serviceability with user replaceable batteries. And all this is available in one of the most affordable UPS systems in its class.
    Quality Power

    The Liebert GXT 2U is a true on-line power source, so whatever the quality of power coming in--the pure sinewave output meets the exacting standards of your equipment. Unlike other UPS technologies, the GXT 2U's design handles all these potential power problems:
     

  • Power spikes and transients
  • EMI/RFI noise
  • Voltage sags and brownout conditions
  • Harmonics
  • Power-factor corrected loads
  • Outages

     

    Built-In Reliability

    The GXT 2U is designed from the inside out for maximum reliability. It includes operating features that simply are not available on other units in its price range:
    Power-factor corrected loads--the GXT 2U maintains stable voltage output even with the power-factor corrected loads typical of modern computer equipment.
    Frequency conversion--allows 60Hz input/50Hz output or 50Hz input/60Hz output with no derating.
    Unlimited external battery connectability -- any number of 2U battery cabinets can be added to supply additional battery time.
    Internal automatic and manual bypass capability -- assures continuity of power to critical loads during system problems or maintenance.

  •  

     

        
      The GXT 2U is easy to install... easy to set up... and even easier to use. It features simple operation with a single switch for uncomplicated, error-free start up. A front-mounted panel displays system status, load levels, battery time remaining and any alarm conditions.   
      For maximum flexibility, the GXT 2U can be easily installed as a space-saving, rack-mounted unit or as a compact freestanding tower. This versatility allows it to be used to protect networks, servers, telecommunications equipment or industrial process equipment...just about anywhere.

    In order to fully protect your network, a UPS must be able to deal with different types of power input, including imperfect power from your electric utility, DC power from batteries, the variable output of most standby generators, and harmonics from inside the building or even from your own network equipment. The Liebert GXT 2U is designed to handle these situations. If a UPS can't provide proper protection under these conditions, then it isn't providing complete protection.

     

    Each GXT 2U is shipped with a Windows® software program that allows the user to program a variety of operating parameters. This capability allows you to customize the GXT 2U's performance to your specific requirements, providing a new level of power protection control and adaptability.

    The software allows configuration of the following:
     

  • Output voltage selectable: 100, 110, 120, 127V
  • Enable or disable auto restart
  • Enable or disable line-neutral reversal detection
  • Select frequency converter mode:
        60Hz input/50Hz output with no derating,
         bypass is disabled

        50Hz input/60Hz output with no derating,
         bypass is disabled

     
  • Change the low battery warning from the standard 2 minutes
  • Select how often you want the automatic battery test to occur
  • Disable automatic battery test if desired
  • Program the UPS for the number of external battery cabinets connected, allowing the UPS to report the correct run time.

     

  •   
    When your computer system can't be without power, even for scheduled UPS maintenance, a Liebert 2U POD™ ensures continuous uptime. The 2U POD provides maintenance bypass capability as well as power output distribution. The 2U POD can be used with your GXT 2U UPS system in either the rack mount or tower configuration.

    The 2U POD allows you to manually transfer your connected equipment to utility power via a maintenance bypass switch, permitting scheduled maintenance or UPS replacement without power disruption. Transferring back to UPS power is equally easy; simply turn the switch to the indicated position and your load is protected by the UPS.

      
    Use of the 2U POD offers many benefits:
     
  • Provides utility power to your attached equipment when switched to maintenance bypass mode.
  • Allows UPS maintenance or replacement of the UPS without discontinuing power to critical equipment.
  • Easily installed--the UPS and utility power are both connected to the 2U POD with the supplied cords.
  • Rotary switch and LED indicators make the unit simple to operate.

     

  • The GXT 2U offers a variety of communications options to provide the monitoring and control capabilities demanded by today's network computing systems.

    Intellislot® SNMP/Web Card

    For enhanced UPS communications and control, the Intellislot SNMP/Web Card will deliver SNMP and web-management communications capability to your GXT 2U unit. This feature will provide flexibility in how you monitor and control your UPS over the network. The card is also easily configurable to work in a standard SNMP implementation and with Liebert's MultiLink unattended shutdown software.

    MultiLink™ Shutdown Software

    Your GXT 2U UPS system can be used with Liebert MultiLink shutdown software. This package automatically shuts down computer operating systems in a smooth and orderly manner if UPS battery capacity runs low.

    Multilink automated shutdown software performs the critical task of protecting information for one computer or a network. It is available in both single and multi-user versions and is designed to run on a wide variety of operating platforms. During an extended utility failure, MultiLink automatically shuts down computer operating systems in a smooth and orderly manner if UPS battery capacity runs low. MultiLink is designed to keep users informed. Notification about critical alarms can be sent to alphanumeric pagers or directly to the computer screen via pop-up messages. MultiLink may be configured for either in-band or out-of-band operation. Using the network to send alarm messages and data can dramatically reduce cable and installation costs. Alternatively, separate communications cables can be run to each computer when network wiring is a concern.

     

      Specifications
    Model Number GXT2-700RT120 GXT2-1000RT120 GXT2-1500RT120
    Model Rating VA/W 700 / 490 1000 / 700 1500 / 1050
    Dimensions: in (mm)
    W x D x H
    3.5x21.5x17 in.
    (89x546x432mm)
    3.5x21.5x17 in.
    (89x546x432mm)
    3.5x21.5x17 in.
    (89x546x432mm)
    Weight: lbs. (kg) 49 lbs. (22 kg) 50 lbs. (23 kg) 51 lbs. (23 kg)
    Input AC Parameters
    Voltage Range 120 VAC nominal, (60 to 140VAC Variable based upon output load)
    Frequency 40 - 70 Hz; Auto Sensing
    Input Power Cord 6 ft. attached, w/NEMA 10 ft. attached, w/NEMA 10 ft. attached, w/NEMA
      5-15 plug 5-15 plug 5-15 plug
    Output AC Parameters
    Output Receptacles (4) NEMA 5-15R (4) NEMA 5-15R (4) NEMA 5-15R
    Voltage 100/110/115/120/127 (user configurable) VAC; ±3%
    Frequency 50 Hz or 60 Hz
    Waveform Sinewave
    Typical Battery Back-up Time
    Full Load 16 minutes 10 minutes 5 minutes
    Recharge Time 5 Hours to 95% capacity after full discharge into 100% load
    Agency
    Safety UL 1778,c-UL Listed (Suitable for Computer Room Applications
    RFI/EMI FCC Part 15, Subpart B, Class A
    Surge Immunity IEEE 587 Category A & B
    Transportation ISTA Procedure 1A


     

    Model Number GXT2-2000RT120 GXT2-3000RT120
    Model Rating VA/W 2000 / 1400 3000 / 2100
    Dimensions: in (mm)
    W x D x H
    3.5x21.5x17 in.
    (89x546x432mm)
    3.5x24.2x17 in.
    (89x615x432mm)
    Weight: lbs. (kg) 55 lbs. (25 kg) 75 lbs. (34 kg)
    Input AC Parameters
    Voltage Range 120 VAC nominal, (60 to 140VAC Variable based upon output load)
    Frequency 40 - 70 Hz; Auto Sensing
    Input Power Cord 10 ft. attached, w/NEMA 5-20 plug 10 ft. attached, w/NEMA 5-30 plug
    Output AC Parameters
    Output Receptacles (4) 5-15R (15/20 amp type) (4) NEMA 5-15R
    (1) NEMA L5-30R on 12 inch cord
    Voltage 100/110/115/120/127 (user configurable) VAC; ±3%
    Frequency 50 Hz or 60 Hz
    Waveform Sinewave
    Typical Battery Back-up Time
    Full Load 5 minutes 5 minutes
    Recharge Time 5 Hours to 95% capacity after full discharge into 100% load
    Agency
    Safety UL 1778,c-UL Listed (Suitable for Computer Room Applications
    RFI/EMI FCC Part 15, Subpart B, Class A
    Surge Immunity IEEE 587 Category A & B
    Transportation ISTA Procedure 1A

     

     

     

    Home - 9 Power Problems - Problems with Power - APC - Powerware - MinuteMan - MGE - Liebert - Batteries - Chargers / Rectifiers - Emergency Lighting - Service - Factory Links

     Contact Us

    Power Factor Inc.

    2526 Manana Dr – Suite 102 – Dallas – Texas – 75220

    NO DISSATISFIED CUSTOMERS!

    Since 1995

    While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
    All names referred to are trademarks or registered trademarks of their respective owners.