Product Description |
| An Easily
Scalable, Incredibly Intelligent, Remarkably Redundant UPS That Takes
Systems Availability To The Next Level
The Nfinity power system is a scalable 4 to 16 kVA UPS, designed with
N+x parallel redundancy to provide a fault-tolerant network of power
protection. Its modular design was devised to provide easy scalability
to users as their power demands grow. Configurations can be
cost-effectively upgraded without re-investing in a new system or
installation.
Nfinity's patent pending frame design houses all of the modular system
components, including 4 kVA power modules, battery modules and system
control modules. By simply installing additional power or battery
modules, you can expand your current system, extend your backup runtime
or add redundancy. Hot-swap capability makes it easy to add or replace
modules.
The system's fault-tolerant design enables the intelligent power and
battery modules to take themselves off-line if there is a problem --
without compromising system integrity. Self-diagnostic capabilities
simplify maintenance and troubleshooting. Nfinity also offers redundancy
in its unique paired system controls, internal and external bypass, and
monitoring options.
|
Ideal Applications
 | Network servers |
 | Enterprise telecommunications systems |
 | LAN gateways, bridges and routers |
 | Mini-computers, superservers and server clusters |
 | Clusters of PCs or workstations and peripherals |
 | RAID arrays and other large-scale data handling systems |
Product Features
 | Scalable for redundancy, power capacity or battery run time, offering
greater flexibility in how you can use the system. |
 | Built-in intelligence is provided by system level and individual
module microprocessor controls, increasing UPS functionality,
communications and reliability. |
 | N+x parallel redundancy is achieved by adding extra power and battery
modules that equally share the electrical load. |
 | In redundant configuration, a failed module will automatically take
itself off-line while the other modules continue to support the connected
equipment. |
 | Multiple and simultaneous communication ports that allow
in-band/out-of-band communications. |
 | Variable input voltage range minimizes battery operation to increase
battery life. |
 | An internal bypass feature ensures the availability of output power
further increasing system availability. |
 | Continuous sinewave output power makes the system compatible with
virtually any type of electronic equipment. |
 | Power factor correction feature reduces reflected distortion and
optimizes utility power conservation. |
 | Communications capability for use with Liebert SiteNet UPS shutdown
monitoring software. |
 | Two-year limited warranty. |
|
| |
|
 |
 |
|
| |
|
The digital lifeblood of
many organizations -- computers, servers, phones, datacom links -- now
resides on networks...outside of the traditional "glass house" protection.
This may make companies more flexible and responsive, but it also makes them
far more vulnerable to power problems, and the threat of catastrophic losses
in sales, customers, productivity...your business lifeblood.
The
solution is a UPS designed like never before
Now for the first time,
your can achieve the highest levels of UPS reliability in a system that is
sized to protect network applications. The Liebert Nfinity UPS is designed
for use with workstations, servers, networks, telecommunications equipment
or other sensitive electronics. It provides continuous, high-quality AC
power to your mission-critical systems, protecting them from any power
aberrations due to blackouts, brownouts, surges or noise interference.
Power protection
The Nfinity power system
is a scalable 4 to 18 kVA UPS, designed with N+x parallel redundancy to
provide a fault-tolerant network of power protection for maximum systems
availability. Its modular design makes Nfinity the most adaptable UPS on the
market, offering easy upgrades and servicing. |
|
 |
 |
 |
 |
|
| |
"High nines"
reliability means 99.99999% system availability. In practical terms, that
means "zero downtime" for mission-critical applications.
Each of these five reliability needs must be met individually, and the
entire protection plan must integrate faultlessly. It requires a new level
of protection planning, and a dedication to seamless execution.
|
 |
|
| |
 |
 |
 |
|
 |
Scalability is Just the Start of the Value
Configure the
system that's right for you today and tomorrow
Everything you need shipped complete, ready for final connection
Intelligence Means Maximum Performance
Power responsiveness
The ability to communicate
Self diagnosis
Highest Levels of Redundancy Mean Maximum Systems Availability
Redundancy at all the critical points of UPS operation
Maintainability without shutdown
Liebert Puts It All Together In The Nfinity UPS System
It looks and works like
no UPS we've offered before. Nfinity's unique frame design houses all of the
modular system components. It contains bays to hold the power modules,
battery modules and system control modules. The modules offer hot-swap
capability, making it easy to add capacity or replace modules. The Nfinity
class of power protection offers a variety of advantages.
|
 |
 |
 |
 |
| |
Nfinity's modular design
was devised to provide easy scalability to users as their power demands grow. By
simply installing additional power or battery modules, you can expand your
current system, extend your backup runtime or add redundancy.
Scalability Provides The Flexibility To Expand
Nfinity's patent-pending
frame design provides the user with the maximum adaptability that is demanded in
todayŐs ever-changing network environment.
Because Nfinity is scalable for redundancy, power capacity or battery run time,
you have greater flexibility in how you can use the system. Configurations can
be cost-effectively upgraded without re-investing in a new system or
installation.
Longer
Battery Run Time
The system's flexible
frame design allows battery backup times to be customized to customer needs
while maintaining a smaller footprint. To extend run times, just add battery
modules. Nfinity also has a faster recharge time than similar units.
12-Bay
And 8-Bay Models Available
Using an 8-bay frame,
Nfinity provides capacities up to 16 kVA in a non-redundant mode and up to 12
kVA in an N+1 redundant mode -- with an incredibly small footprint (only 20"W x
28"D x 41"H). In an 8-bay frame, power modules must only be used in the top half
of the frame with a maximum of four modules. Up to seven battery modules can be
installed in any of the bays.
The 12-bay frame provides
up to 18 kVA, with or without redundancy, in the same footprint as the 8-bay
unit and only 54" high. An 18 kVA system will actually have 20 kVA of power
capacity, however, the actual output power is limited to 18 kVA to allow direct
connection to a 100A feeder. The 12-bay frame can utilize up to six power
modules in the top half of the frame and as many as 11 battery modules installed
in any of the bays.
 |
 |
 |
|
 |
Nfinity is the most
intelligent power system we've ever built. The fault-tolerant design enables
the power, battery and control modules to take themselves "off-line" if
there is a problem, without compromising system integrity. System level and
individual module microprocessor controls increase UPS functionality and
reliability. When Nfinity modules are inserted, they perform a full
self-diagnostic test before going on-line.
IntelliControl™
Module -- The system control module works with the user interface to
provide vital information about the condition of the power and battery
modules. The use of a paired system control provides full systems
functionality in the event of any single failure and ensures that operations
and communications are always available.
IntelliBattery™
Module -- Nfinity's patent pending innovative battery module
continuously monitors the battery's voltage, current, and temperature to
determine the state of its batteries and predict performance. Each module
contains an intelligent battery sensing circuit that will take it off-line
if a problem is detected, so as not to affect the performance of other good
battery modules in the system. |
|
 |
 |
Intelligent Power Modules -- provide protection against power outages,
spikes, surges, noise, and sags. Designed in 4 kVA "building blocks," they
utilize patent pending current sharing technology that ensures premium
quality power. Nfinity power modules feature a power factor corrected (PFC)
rectifier to create a sinusoidal input current waveform. This allows the
system to use utility power more efficiently and reduces reflected
distortion. A true on-line system, Nfinity provides continuous, regenerated
sinewave output power.
Intelligent Bypass
-- The patent pending Intelligent Bypass technology provides seamless
transfers to and from the bypass source to insure continuity of power and
provide maximum system availability. |
Communications Capability
The Liebert Nfinity UPS
incorporates extensive firmware designed to provide a comprehensive range of
control and operating information, as well as communications capability. |
|
Communication Connections
Dry contacts and a serial
communications port are standard. The unit also includes four Intellislot™
ports for multiple user options including:
SNMP/WEB card that allows the Nfinity to communicate with an Ethernet
network.
MultiPort4 cards that enable up to four client computers to monitor UPS
status.
Relay contact cards to provide contact closures for remote monitoring of
alarm conditions.
The system also communicates to and monitors internal and extended
battery cabinets.
|
|
Shutdown Monitoring Software
MultiLink™ is the perfect
complement to the Liebert Nfinity UPS because it prevents unexpected server
shutdowns, protects data and minimizes downtime. The software provides
unattended, orderly shutdown for one computer or many, and is especially
effective with large server farms. MultiLink has full event management and
displays UPS instrumentation on screen. MultiLink is available for all
popular operating systems and can be downloaded from the Liebert website at
www.liebert.com. |
User
Interface Control Panel
The user interface is the
main source of communication between the Nfinity UPS and the user. It features
an easy-to-read LCD display and LED mimic diagram. The control panel informs the
user of the status of the UPS, including the power and battery modules, and
allows you to configure the system to fit specific needs or preferences. You can
also review the event log and even receive instructions on replacing modules.
| |
 |
 |
|
| |
The
modular design of Nfinity allows you to choose the amount of redundancy you
need with greater flexibility than competitive systems. When in a redundant
configuration, a failed module will automatically take itself off-line while
the other modules continue to support the connected equipment.
Nfinity is a 4 to 18
kVA UPS designed with N+x parallel redundancy to provide a fault tolerant
network of power protection for maximum systems availability. |
|
 |
 |
Redundant Power Modules -- parallel redundancy is achieved by adding
extra power modules that equally share the electrical load.
Redundant Battery
Modules -- multiple battery modules can provide redundancy capability in
addition to extended run time.
Redundant System
Controls -- provide full functionality in the event of any single
failure and ensure that operations and communications are always available.
Internal Bypass
-- assures continuity of power to critical loads. A synchronized internal
bypass provides seamless transfers to and from utility power.
Redundant
Monitoring Options -- multiple communications paths provide separate
connections for contact closures, serial communications and four Intellislot™
communications ports to monitor the UPS system both in-band and out-of-band.
Engineered For
Reliable Operation -- Nfinity is designed with a lower parts count than
other products in its class to help assure more reliable operation by
reducing the potential points of failure. For even greater reliability, fan
filters are included for dusty, back office environments.
Factory Pre-Tested
And Shipped Ready To Install -- Nfinity is the first redundant UPS of
its kind that ships as a complete, pre-configured system that is fully
tested at the factory. Everything you need is included in a single package
that's ready to roll in and hook up. |
 |
 |
 |
 |
 |
Maintenance Bypass Cabinet
The Nfinity
maintenance bypass cabinet provides complete "wrap around" protection,
allowing the Nfinity UPS to be pulled from service without interrupting
power to the protected loads. The maintenance bypass cabinet controls
are located behind a lockable front panel to provide operational
security. Controls include a manual bypass transfer switch, UPS input
disconnect switch and a branch rated output circuit breaker. Indicator
lamps provide visual confirmation that the UPS input, UPS output, and
bypass source are available. |
|
 |
 |
| |
 |
Extended Battery Cabinets
The Nfinity extended
battery cabinet is available when extra run time is critical to your
protected loads. This unit has 12 bays that accept up to 12 standard
Nfinity intelligent battery modules, allowing you to add battery
capacity as needs change. A built-in microprocessor in each battery
module provides the intelligence and communication capability to allow
the module to automatically remove itself from the critical DC bus if
necessary. The extended battery cabinet reports and tracks individual
module capacity, temperature and charge level, as well as other data and
reports this information to the Nfinity system control. |
|
|
| |
Configurable Output Distribution
The Nfinity
configurable output distribution option provides the flexibility to
easily connect multiple loads with various receptacle types and current
ratings to the Nfinity. Receptacles range from 15A to 30A types and
include a branch rated circuit breaker to protect each individual load.
Other output distribution options include hardwire landing plates; both
with and without branch rated circuit breakers. You can select a maximum
frame size of 6, 8, or 10 distribution plates, as well as a choice of 6,
12, or 25 feet of cabled conduit between the Nfinity and the output
distribution. |
|
| These are
the attributes that make Liebert Worldwide Services the leader in uptime
services for critical systems. Since 1965 -- and through many generations of
computers and peripherals -- Liebert power and environmental products and
support services have provided peace of mind to thousands of companies
worldwide. Today, companies rely more than ever on complex facility systems
and face greater risks when unexpected disaster strikes. These outages not
only cause the loss of important data but also affect performance and
profitability. |
|
 |
More than 35,000
customers in 70 countries around the world trust Liebert Worldwide Services
to minimize critical system emergencies and interruptions. We're backed by
the largest technical support and customer response system in the |
|
industry
with more than 1,000 factory-trained and company-employed service
professionals in more than 100 service centers ready to assist in
maintaining your uptime, 24 hours a day, every day of the year. |
|
To
enhance the reliability and trouble-free operation of your Nfinity UPS,
Liebert Worldwide Services offers a range of optional ServicePlus programs
which include: |
|
 |
Start-Up
The best UPS system in
the world can't operate right if it's not installed properly. During the
start-up process, the proper installation and operation of your new Nfinity
UPS is verified by our factory-trained customer engineer. This verification
ensures that the unit, the installation and the environment meet published
specifications for design use. Operator training is also provided.
Remote
Monitoring
Remote monitoring is our
comprehensive service program connecting your Nfinity UPS to our 24 x 7
Customer Response Center (CRC). The CRC continuously monitors your critical
equipment, detects alarms, and initiates a response according to a
customized, predetermined corrective action plan. |
|
Customer Response Center
When a customer call or
alarm is received at our Customer Response Center (CRC), it activates the
Liebert Worldwide Services 24-hour service network. This network provides
immediate two-way radio access to our factory-trained customer engineers
through our wireless communication system. Our Customer Response Center,
located in Columbus, Ohio, is staffed exclusively by Liebert Worldwide
Services' associates.
Exclusive Guaranteed Six-Hour Response Time
We can guarantee a
six-hour response time -- from the time your call is received at our CRC
until a Liebert Customer Engineer arrives on-site (applicable in U.S. and
Canada -- distance limitations apply). |
|
Preventive Maintenance
Preventive maintenance
visits are designed to assess the status of your installed equipment and
make any necessary corrective adjustments or repairs. The level of service
you select for your Nfinity UPS determines the number of scheduled visits.
Two-Year Factory Warranty Program
Liebert's two-year
warranty provides for repair or replacement of your Nfinity UPS during the
initial warranty period. |
|
| |
 |
 |
 |
 |
| |
Nfinity's modularity and
scalability allow you to specify a system that is right for your needs today
-- but has the ability to expand with your requirements for the future.
Wider
Input Voltage Window
A wider, variable input
voltage range minimizes transfer to battery to increase battery life. For
lighter loads, low line transfer can range down to 110V.
Generator Compatible
Full time output voltage
and frequency regulation is provided -- a necessity for sensitive electronic
equipment and a must for sites with back up generators.
Highest Overload Capability
Nfinity offers the
highest overload capability of any system in its class -- capable of
sustaining 110% of the system's rated load for an extended period of time. |
Specifications
|
General &
Environmental |
Units |
4 |
8 |
12 |
16 |
18 |
| Unit Rating |
kVA |
4 |
8 |
12 |
16 |
18 |
| |
kW |
2.8 |
5.6 |
8.4 |
11.2 |
12.6 |
| Conducted &
Radiated EMC Levels |
FCC Part 15, Class A |
| Compliant Safety
Standards |
UL 1778; c-UL |
| Compliant
Immunity Standards |
IEEE C62.41, Category
B |
|
Mechanical |
Units |
8 Bay |
12 Bay |
| Dimensions: Width |
|
20 (508) |
20 (508) |
| Dimensions: Depth |
In
(mm) |
28 (711) |
28 (711) |
| Dimensions:
Height |
|
41 (1041) |
54 (1372) |
|
Environmental |
Units |
4 |
8 |
12 |
16 |
18 |
| Operating
Temperature (max) |
F
(C) |
32ˇ-104ˇ (0ˇ-40ˇ) |
| Relative Humidity |
|
0-95% non-condensing |
| Maximum Operating
Altitude |
Ft. (M) |
10,000 (3,000) |
| Nominal Heat
Dissipation |
BTU/Hr |
1062 |
2124 |
3186 |
4248 |
4781 |
|
Input Data |
Units |
|
| Nominal Input
Voltage |
VAC |
170 to 276 |
| |
VAC |
110-276 (variable,
based on output load) |
| Power Factor |
Cos Ř |
>.98 |
| Input Frequency
(nominal) |
Hz |
60 |
| Input Frequency
Range |
Hz |
40-70 |
|
Battery Module |
Units |
|
| Battery Capacity |
A/hr |
9 |
| Autonomy Time
(full load) |
Mins |
6
With an equal number of Battery & Power Modules
in a non-redundant configuration |
| Maximum Charge
Current (full load) |
A |
3 |
| Nominal Voltage |
VDC |
120 |
| Recharge Time |
Hrs |
3-5 (to 90% capacity) |
|
Output Data |
Units |
|
| Output Voltage |
VAC |
208/120 or 240/120 |
| Voltage
Regulation |
% |
±3 |
| Voltage Transient
Response (100% step load) |
% |
±7 |
| Voltage Stability
(100% step load) |
% |
±7 |
| Recovery Time |
msec |
96 |
| Voltage
Distortion |
% |
<3 THD, linear load
<7 THD, non-linear load |
| Output Frequency |
Hz |
60 |
| Efficiency at
100% load |
% |
89 |
| Output Overload
Capacity |
% |
110-125% for 10 min
126-150% for 10 sec
>151-200% for 2 cycles |
|
|
 |
 |
|
|