| Description |
APC Smart-UPS,
3000VA/2250W, Extendable Run Time , Input 120V/ Output 120V |
 |
| General Features |
Extendable Run
Time , Hot Swap Batteries , Intelligent Battery Management , Overload
Indicator , Replace Batt Indicator , SmartSlot , Software , Site wiring
fault indicator , Automatic Voltage Regulation (AVR) , User Replaceable
batteries |
 |
| Includes |
User Manual ,
Smart UPS signalling RS-232 cable , CD with software |
 |
| Documentation |
User Manual
|
 |
| Optional Versions |
optional
versions . |
 |
 |
 |
Technical Specifications |
 |
|
|
Output |
 |
| Rated Power |
3,000 VA |
 |
| Output power
capacity |
2,250 Watts |
 |
| Nominal output
voltage |
120 V |
 |
| Output Connections |
|
(8)NEMA 5-15R |
|
|
 |
| Optional AC
Connection |
optional
AC Connections. |
 |
| Waveform type |
Sinewave |
 |
 |
|
Input |
 |
| Nominal input
voltage |
120 V |
 |
| Input frequency |
50/60 Hz +/- 3 Hz
(auto sensing) |
 |
| Input Connection
Type |
|
NEMA L5-30P (30A
Twist-Lock) |
|
|
 |
| Cord Length |
6 feet |
 |
Input voltage
range
for main operations |
92 - 147 V |
 |
| Input voltage
adjustable range for main operations |
86 - 154 V |
 |
 |
|
Batteries |
 |
Typical backup
time
at half load |
18.1 minutes |
 |
| Battery type |
Maintenance-free
sealed Lead-Acid battery with suspended electrolyte : leakproof |
 |
| Typical recharge
time |
3 hour(s) |
 |
| Replacement
battery cartridge |
(1)
RBC11 |
 |
| Optional Battery |
optional
Batteries. |
 |
 |
|
Communications & Management |
 |
| Interface port |
DB-9 RS-232,
Smart-Slot card |
 |
| Smart Slot
Interface Quantity |
1 |
 |
| Management
software included |
PowerChute Smart-UPS Bundle |
 |
| Optional Software |
other
Software options . |
 |
| Control panel |
LED status display
with load and battery bar-graphs and On Line : On Battery : Replace Battery
: and Overload Indicators |
 |
| Audible alarm |
Alarm when on
battery : distinctive low battery alarm : configurable delays |
 |
| Emergency Power
Off (EPO) |
Optional |
 |
| Optional
Management Device |
optional
Management Devices. |
 |
 |
|
Surge Protection and Filtering |
 |
| Surge energy
rating |
320 Joules |
 |
| Filtering |
Full time
multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping
response time : meets UL 1449 |
 |
 |
|
Physical |
 |
| Maximum height
dimensions |
17.00 inches (
43.18 cm) |
 |
| Maximum width
dimensions |
7.70 inches (
19.56 cm) |
 |
| Maximum depth
dimensions |
21.50 inches (
54.61 cm) |
 |
| Net weight |
123.00 lbs (
55.91 kg) |
 |
| Shipping weight |
142.00 lbs (
64.55 kg) |
 |
| Shipping Height |
22.00 inches (
55.88 cm) |
 |
| Shipping Width |
15.00 inches (
38.10 cm) |
 |
| Shipping Depth |
30.00 inches (
76.20 cm) |
| Color |
Beige |
 |
| Units per Pallette |
3.0 |
 |
 |
|
Environmental |
 |
| Operating
Temperature |
0 - 40 °C (32 -
104°F) |
 |
| Operating Relative
Humidity |
0 - 95% |
 |
| Operating
Elevation |
0-10000 feet
(0-3000 m) |
 |
| Storage
Temperature |
-15 - 45 °C (5 -
113°F) |
 |
| Storage Relative
Humidity |
0 - 95% |
 |
| Storage Elevation |
0-50000 feet
(0-15000 m) |
 |
| Audible noise at 1
meter from surface of unit |
53 dBA |
 |
| Online thermal
dissipation |
375 BTU/hr |
 |
 |
|
Conformance |
|
 |
| Approvals |
CSA, FCC A, UL
1778 |
 |
| Standard warranty |
2 years repair or
replace , optional on-site warranties available , optional extended
warranties available |
 |
| Equipment
protection policy |
$25000 lifetime equipment protection policy |