LITE 2™ Series
Lampak II Series
Lampak Series
Delite Series
T-Bar Series

 

Lampak Series
Emergency fluorescent power packs



Agency Approvals:
UL Approved
Features
Dual-Lite LAMPAK series emergency fluorescent power packs are designed to be connected to planned or existing fluorescent fixtures, eliminating the need to install additional emergency lighting units. All unit housings are constructed of 19-gauge sheet metal finished in black enamel. The unit contains a solid-state charger with automatic transfer circuit; a dependable, high-frequency inverter; a high-temperature, nickel-cadmium battery; a test switch; and charger indicator light. LAMPAK emergency fluorescent power packs are supplied with connection leads of sufficient length to accommodate all standard applications.
 


 

bulletCompatible with standard, energy-saving, dimming electronic AC ballasts
 
bulletFor use with HO, VHO, U-shaped, circline, energy-saving and rapid-start (4-pin) lamps
 
bulletReliable, high-frequency inverter
 
bulletHigh-temperature, nickel-cadmium battery
 
bulletUniversal 120/277 VAC operation
 
bulletUL listed
 
bulletEmergency power packs mount inside of ballast channel, on top of fixture or remotely up to 50 feet away from connected fixture
 
bulletEmergency illumination exceeds UL, NEC and NFPA Life Safety Code requirements
 
bulletProvides a minimum of 90 minutes of emergency power
 
bulletTest switch
 
bulletCharging indicator light
 
bullet24-hour recharge time
 
bulletLow power consumption
 
bulletFor use with switched or unswitched fixtures
 



Specification:
LAMPAK Series emergency power packs are capable of illuminating most 20W through 215W (2’ - 8’) fluorescent lamps, including U shaped, HO, VHO, circline, energy-saving and rapid-start long compact fluorescents as outlined below. Lumen output may vary depending on lamp construction and age.

UFO-3A:
Illuminates one 20W through 40W - T8, T10 or T12 diameter fluorescent lamp for 90 minutes. Initial emergency lighting output is 350-450 lumens.

UFO-4:
Illuminates one 20W through 40W - T8, T10 or T12 diameter fluorescent lamp for 90 minutes. Initial emergency lighting output is 500-600 lumens. Lumen output is less with 4-pin long compact fluorescent lamps.

UFO-5:
Illuminates one 20W through 215W - T8, T10 or T12 diameter fluorescent lamp for 90 minutes [20W through 40W, (2’ - 4’), T12 diameter lamps for 120 minutes]. Initial emergency lighting output is 600-700 lumens. Lumen output is less with 4-pin long compact fluorescent lamps.

UFO-5A:
Illuminates two 20W through 40W (2’-8’) T8, T10 or T12 diameter fluorescent lamps, or one 20W through 215W (2’-8’) tubular lamp or 4-pin compact fluorescent lamp at reduced illumination in emergency mode for a minimum of 90 minutes. Initial emergency lightning output is 600-700 lumens. With two lamp output, light output is evenly divided between the two lamps. Lumen output will be less with one lamp operation or with compact fluorescent lamps.

UFO-6:
Illuminates one 20W through 215W fluorescent lamp or two 20W through 40W (2’ - 4’) T8, T10 or T12 diameter lamps for 90 minutes. Initial emergency lighting output is 1100 - 1400 lumens. Initial light output for long compact fluorescent lamps is 700 - 1000 lumens. Lumen output is less with 4-pin long compact fluorescent lamps.

For questions regarding specific lamp compatibility, contact factory.


Application/Installation:
For use in new or retrofit applications where an easily installed, economical means of providing emergency power to fluorescent fixtures is required.

LAMPAK Series emergency power packs offer great versatility in mounting methods. The unit may be mounted externally on the fixture housing or internally within the unit ballast chamber. LAMPAK emergency power packs do not affect normal fixture operation and may be used with either switched or unswitched fixtures. An extension tube for the charger indicator light is provided for use with lensed fixtures. The extension tube allows the charger indicator light to be located in close proximity to the fixture lens for confirming charger operation without having to open the fixture. Installation is not recommended in fixtures where the ambient LAMPAK unit temperature may fall below 0° Celsius for extended periods. LAMPAK Series emergency power packs are also not suitable for installation in heated air outlet fixtures and wet or hazardous location fixtures. LAMPAK models are compatible with standard, energy-saving, dimming and electronic AC ballasts.

 

Detailed Part Number Information:
Part Number
Description
Details  Specifications
Item Number
UFO-10
Emergency Fluorescent Pack
 
Weight = 3.5Lbs
UFO-11
Emergency Fluorescent Pack
 
Weight = 4.0Lbs
UFO-12
Emergency Fluorescent Pack
 
Weight = 3.5Lbs
UFO-3A
Emergency Fluorescent Pack
 
Weight = 2.3Lbs
UFO-4
Emergency Fluorescent Pack
 
Weight = 2.3Lbs
UFO-5
Emergency Fluorescent Pack
 
Weight = 2.3Lbs
UFO-5A
Emergency Fluorescent Pack
 
Weight = 2.3Lbs
UFO-6
Emergency Fluorescent Pack
 
Weight = 2.3Lbs
Accessories
F-WC
Wire Bundle Cover
 
Weight = 1.0Lbs

 

Home Batteries  UPS Technology Emergency Lighting Battery Chargers Factory Links Contact Us Buy Batteries Online

Power Factor Inc.

2526 Manana Dr – Suite 102 – Dallas – Texas – 75220

 Our Goal, NO DISSATISFIED CUSTOMERS!

Since 1995

While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.