|
Contact Us Toll Free
Buy
batteries on-line

Request Info
UPS Systems
Batteries
Emergency Lighting
Battery
Chargers
Battery Storage
Specials!
Service
Lease Info
| |
HLXA Series
Hazardous
Location Emergency Lighting Units |

Agency Approvals:
UL listed to: standard 924
(Emergency Lighting Equipment), standard 844 (Hazardous Locations
Classified), standard 1570 (Fluorescent Lighting Fixtures)
HLXA series units are listed for operation in NEC classifications:
HLXA1:
Class I, Div. 2, Groups A, B, C, D
Class II, Div. 1 & 2, Groups E, F, G
Class III
HLXA2:
Class II, Div. 1 & 2, Groups E, F, G
Class III
Suitable for use in wet locations
|
Features
The HLXA hazardous
location emergency lighting series is designed to provide safe operation
in the presence of volatile gases, vapors or dusts. The outlet box and
tank are cast from high-strength, copper-free aluminum, with
corrosion-resistant stainless steel exterior hardware. A gray,
electrodeposition-applied epoxy-clad finish, provides uniform coverage
and maximum corrosion-resistance. A one-piece silicone gasket provides
superior sealing. Stainless steel battery vent provided.
 | Completely assembled, self-contained
|
 | Operates for 90 minutes (minimum)
|
 | Available in emergency use only (lamps normally “off”) or
continuous operation units
|
 | Two, 13-watt, long-life, high-output, quad type fluorescent lamps
|
 | For added safety, each lamp has its own independent battery pack
|
 | Sealed, maintenance-free, nickel-cadmium batteries
|
 | Solid-state, constant current battery charging circuit
|
 | High-strength, copper-free aluminum castings
|
 | Electrodeposition, gray, epoxy-clad finish for uniform coverage
and maximum corrosion resistance
|
 | Corrosion-resistant, stainless steel exterior hardware
|
 | Heat-resistant, prismatic glass globe for superior optics
|
 | One piece silicone gasket provides superior sealing
|
 | Hinge design provides extra protection against accidental housing
disengagement during installation or maintenance
|
 | Latch assembly “swing-away” design simplifies servicing
|
 | Emergency use only units (lamps normally “off”) have universal
transformer for 120 or 277VAC operation
|
 | Red light indicates “AC On/Battery Charging”
|
 | Models available for wall, pendant or ceiling mounting
|
 | High-strength, copper-free aluminum globe guards with gray,
epoxy-clad, corrosion-resistant finish
|
 | Stainless steel battery vent
|
 | Accessories include: standard dome or 30° white polyester
reflectors, auxiliary fixture housing with “exit” legend, test switch
to verify emergency operation, fuse kit
|
 | Suitable for use in wet locations
|
Specification:
Standard illumination is
provided by two, 13-watt, quad type fluorescent lamps. A heat-resistant,
prismatic glass globe provides superior optics. Units are supplied
standard with high-strength, copper-free aluminum globe guards. The
usual design objective in emergency lighting is to provide a level of
illumination sufficient to allow people to leave a building in the event
of a power failure or other emergency condition.
Application/Installation:
For use in hazardous
locations or adverse environment areas requiring a self-contained
emergency lighting unit designed for safe operation in the presence of
volatile gases, vapors or dust.
Designed for easy installation. Models with mounting adapters are
available for wall, pendant or ceiling installation. The outlet box on
units intended for pendant or ceiling mounting is provided with 3 /4"
(optional 1") NPT threaded hub ports (plugged) for connection of the
lighting branch circuit conduit. Units intended for wall mounting are
supplied with an integral outlet box/mounting fixture that provides the
branch circuit connection point. On all units, a unique hinge and latch
arrangement allows separation of the outlet box and tank, providing
simplified servicing and component support.
|
|
| Detailed
Part Number Information: |
Part Number
Description |
Details |
Specifications |
|
Item Number |
HLXA1CCG(120V)
Hazardous Location Emergency Lighting Unit |
Continuous
Operation (Lamps Normally "On") and Emergency Operation with Globe Guard -
Ceiling Mount, 3/4" Hub
Class I, Div. 2, Groups A, B, C, D; Class II, Div. 1 & 2, Groups E, F, G,
Class 3 |
Weight = 19.4Lbs |
HLXA1CCG(277V)
Hazardous Location Emergency Lighting Unit |
Continuous
Operation (Lamps Normally "On") and Emergency Operation with Globe Guard -
Ceiling Mount, 3/4" Hub
Class II, Div. 1 & 2, Groups E, F, G, Class 3 |
Weight = 19.4Lbs |
HLXA1CEG
Hazardous Location Emergency Lighting Unit |
Emergency
Operation Only (Lamps Normally "Off") with Globe Guard - Ceiling Mount, 3/4"
Hub
Class I, Div. 2, Groups A, B, C, D; Class II, Div. 1 & 2, Groups E, F, G,
Class 3 |
Weight = 19.4Lbs |
HLXA1PCG(120V)
Hazardous Location Emergency Lighting Unit |
Continuous
Operation (Lamps Normally "On") and Emergency Operation with Globe Guard -
Pendant Mount, 3/4" Hub
Class I, Div. 2, Groups A, B, C, D; Class II, Div. 1 & 2, Groups E, F, G,
Class 3 |
Weight = 18.7Lbs |
HLXA1PCG(277V)
Hazardous Location Emergency Lighting Unit |
Continuous
Operation (Lamps Normally "On") and Emergency Operation with Globe Guard -
Pendant Mount, 3/4" Hub
Class II, Div. 1 & 2, Groups E, F, G, Class 3 |
Weight = 18.7Lbs |
HLXA1PEG
Hazardous Location Emergency Lighting Unit |
Emergency
Operation Only (Lamps Normally "Off") with Globe Guard - Pendant Mount, 3/4"
Hub
Class I, Div. 2, Groups A, B, C, D; Class II, Div. 1 & 2, Groups E, F, G,
Class 3 |
Weight = 18.7Lbs |
HLXA1WCG(120V)
Hazardous Location Emergency Lighting Unit |
Continuous
Operation (Lamps Normally "On") and Emergency Operation with Globe Guard -
Wall Mount, 3/4" Hub
Class I, Div. 2, Groups A, B, C, D; Class II, Div. 1 & 2, Groups E, F, G,
Class 3 |
Weight = 20.6Lbs |
HLXA1WCG(277V)
Hazardous Location Emergency Lighting Unit |
Continuous
Operation (Lamps Normally "On") and Emergency Operation with Globe Guard -
Wall Mount, 3/4" Hub
Class II, Div. 1 & 2, Groups E, F, G, Class 3 |
Weight = 20.6Lbs |
HLXA1WEG
Hazardous Location Emergency Lighting Unit |
Emergency
Operation Only (Lamps Normally "Off") with Globe Guard - Wall Mount, 3/4"
Hub
Class I, Div. 2, Groups A, B, C, D; Class II, Div. 1 & 2, Groups E, F, G,
Class 3 |
Weight = 20.6Lbs |
HLXA2CCG(120V)
Hazardous Location Emergency Lighting Unit |
Continuous
Operation (Lamps Normally "On") and Emergency Operation with Globe Guard -
Ceiling Mount, 3/4" Hub
Class I, Div. 2, Groups A, B, C, D; Class II, Div. 1 & 2, Groups E, F, G,
Class 3 |
Weight = 19.4Lbs |
HLXA2CCG(277V)
Hazardous Location Emergency Lighting Unit |
Continuous
Operation (Lamps Normally "On") and Emergency Operation with Globe Guard -
Ceiling Mount, 3/4" Hub
Class II, Div. 1 & 2, Groups E, F, G, Class 3 |
Weight = 19.4Lbs |
HLXA2CEG
Hazardous Location Emergency Lighting Unit |
Emergency
Operation Only (Lamps Normally "Off") with Globe Guard - Ceiling Mount, 3/4"
Hub
Class I, Div. 2, Groups A, B, C, D; Class II, Div. 1 & 2, Groups E, F, G,
Class 3 |
Weight = 19.4Lbs |
HLXA2PCG(120V)
Hazardous Location Emergency Lighting Unit |
Continuous
Operation (Lamps Normally "On") and Emergency Operation with Globe Guard -
Pendant Mount, 3/4" Hub
Class I, Div. 2, Groups A, B, C, D; Class II, Div. 1 & 2, Groups E, F, G,
Class 3 |
Weight = 18.7Lbs |
HLXA2PCG(277V)
Hazardous Location Emergency Lighting Unit |
Continuous
Operation (Lamps Normally "On") and Emergency Operation with Globe Guard -
Pendant Mount, 3/4" Hub
Class II, Div. 1 & 2, Groups E, F, G, Class 3 |
Weight = 18.7Lbs |
HLXA2PEG
Hazardous Location Emergency Lighting Unit |
Emergency
Operation Only (Lamps Normally "Off") with Globe Guard, Pendant Mount, 3/4"
Hub
Class I, Div. 2, Groups A, B, C, D; Class II, Div. 1 & 2, Groups E, F, G,
Class 3 |
Weight = 18.7Lbs |
HLXA2WCG(120V)
Hazardous Location Emergency Lighting Unit |
Continuous
Operation (Lamps Normally "On") and Emergency Operation with Globe Guard -
Wall Mount, 3/4" Hub
Class I, Div. 2, Groups A, B, C, D; Class II, Div. 1 & 2, Groups E, F, G,
Class 3 |
Weight = 20.6Lbs |
HLXA2WCG(277V)
Hazardous Location Emergency Lighting Unit |
Continuous
Operation (Lamps Normally "On") and Emergency Operation with Globe Guard -
Wall Mount, 3/4" Hub
Class II, Div. 1 & 2, Groups E, F, G, Class 3 |
Weight = 20.6Lbs |
HLXA2WEG
Hazardous Location Emergency Lighting Unit |
Emergency
Operation Only (Lamps Normally "Off") with Globe Guard - Wall Mount, 3/4"
Hub
Class I, Div. 2, Groups A, B, C, D; Class II, Div. 1 & 2, Groups E, F, G,
Class 3 |
Weight = 20.6Lbs |
|
Accessories |
HLXAAR
Angled (30o) Dome Reflector |
|
Weight = 2.5Lbs |
HLXADR
Standard Dome Reflector |
|
Weight = 1.0Lbs |
HLXAEF
Three Sided Exit Fixture |
|
Weight = 5.0Lbs |
HLXA-FK
Ballast Fuse Kit |
|
Weight = 0.5Lbs |
HLXA-TS
Remote Mounted Test Switch |
|
Weight = 2.7Lbs |

|