Lease Info

 

 

The advanced design Spectron LSN System utilizes PWM technology to provide 100% compatibility with all connected life safety loads. "No Break" sinusoidal output assures that even voltage-sensitive or frequency-sensitive loads will operate normally during emergency operation. Utilizing the latest IGBT (insulated gate bipolar transistor) technology, the Spectron LSN has an AC-in to AC-out efficiency of 98%. Self diagnostics, reduced maintenance and greater reliability make the Spectron LSN the most innovative inverter system on the market today.
Interruption-Free Power
Spectron LSN Provides continuous power to all critical life safety loads and other secondary support systems. This "no break" switching between utility and inverter power means that all connected equipment will continue to operate normally under emergency conditions.
Voltage Regulation
Spectron LSN's Boost Tap Regulation protects your loads from "brownouts" and recurrent low-voltage transients by sensing any drop in voltage and "boosting" the voltage back up to nominal without drawing from the batteries and shortening their lives.
Mixed Loads
Spectron LSN's "no break" design provides continuous operation to mixed loads regardless of power factor. Capacitive, inductive or resistive loads will operate normally as will voltage-sensitive or frequency-sensitive equipment.

Features
The Spectron LSN Life Safety Network is designed
to provide:

- A simplified system approach to emergency lighting and power
- "No break" power
- Pulse width modulated technology
- 100% load compatibility
- Maximized reliability
- Reduced maintenance expense
- Enhanced security
- Improved building aesthetics
- Minimized space requirements
- Communications capability

Most importantly, it delivers optimum safety for building occupants.

Advanced Design
The basic elements of an inverter system are batteries, an inverter, a charger and a transformer. Spectron LSN, however, is unlike traditional IPS, FT or UPS systems because of its innovative design.

This pulse width modulated (PWM) high-frequency inverter utilizes the latest IGBT (Insulated Gate Bipolar Transistor) technology. The AC-in to AC-out operating efficiency is 98%, well above other central inverter system equipment.

Communications
All Spectron LSN inverter systems are equipped with an RS232 communication interface designed to give the user greater flexibility in monitoring and controlling the system.

Big Performance...Small Footprint
Spectron LSN inverter system’s feature-rich design is provided in an incredibly compact package. Spectron LSN system capacities under 5KVA require less than four square feet of floor space; all other systems up to 15KVA require less than eight square feet - the smallest footprints in the industry!

Compatibility
Spectron LSN systems provide 100% compatibility with all connected loads. “No break” sinusoidal output assures that even voltage-sensitive or frequency-sensitive loads will operate normally during emergency operation.

Simplicity
- Single, centrally located power source
- Intelligent, easy-to-use interface panel
- Automatic, programmable self-diagnostic operation
- Utilizes existing lighting fixtures for emergency illumination
- No secondary backup power or lighting equipment required
- Connects into existing electrical panel - no special wiring required

Safety
- Audio-visual service alarms
- Meets or exceeds all UL 924 and UL 1778 requirements
- Digitally generated sine wave output
- 50,000 RMS symmetrical ampere short-circuit rating
- Built-in backfeed relay to protect personnel from potential shock hazard

Security
- Spectron LSN systems are normally installed
  in utility areas away from normal public access
- Locking cabinetry prevents tampering
- Password-protected user interface prevents
  operation by unauthorized personnel



Application/Installation:
Field Support
During or after installation, our Systems Service Department is available to provide expert assistance. Our service representatives are available to answer customers’ questions or solve their problems.

Toll-Free Number
A toll-free phone has been set up for Spectron LSN service questions. The number is: 1-800-848-6439 For our customers’ convenience, this phone number is printed on the inside of the unit’s cabinets.

Application Support
Dual-Lite’s representatives provide application assistance and customer support to meet your needs. Through training, technical support literature and the assistance of factory application engineers, representatives will work with the engineer and end-user to select the proper system.

Factory Start-Up (FS)
Factory Start-Up is designed to insure proper operation and installation of the Spectron LSN inverter system. It provides for a highly trained factory-authorized technician to administer an on-site, point-by-point visual check of the system. Included is a check of all internal electrical connections, AC and battery connections, system voltages and all system operating parameters. The system is then powered up and all system parameters are tested, calibrated and recorded. The technician will also perform a battery discharge test to insure proper battery capacity. If any malfunctions are detected, the technician will remedy them while on site (depending on the availability of parts), or make arrangements to do so. The technician will instruct on-site personnel about the operation and maintenance of the equipment. Warranty of the equipment will commence on the start-up date.

Service Agreement (SA)
Provides for an annual visit by a factory-authorized technician to test all system options and related accessories. Technician will perform a physical and mechanical inspection of all batteries and battery connections. Included will be a test, calibration and recording of the system charger output, battery float voltages and all input/output settings. Technician will also perform a simulated power outage, discharging the batteries to 87.5% of nominal voltage and record readings of individual battery voltages.

Monitoring Program (MP)
Requires Factory Start-Up (FS) and Fax Modem (FAX) options. It provides for the continuous monitoring of the equipment by our Technical Support Group. All monthly and yearly system tests will be reviewed and analyzed for early warning signs of system malfunctions. Any failures will be automatically relayed to our Service Department where corrective action can be taken. This Monitoring Program is the only automated failure reporting system in the industry. It requires a dedicated analog telephone line, to be provided by the customer.

Spectron LSN Features
Spectron LSN System Features and Design

Features
A solid-state charger transforms the incoming utility voltage into a regulated DC supply voltage to charge the batteries.

A maintenance-free battery is provided on standard models to maintain power to the inverter. The batteries are fitted with a suitably rated DC switch and fuse to provide overload and short-circuit protection and also allow isolation from the system for maintenance purposes.

A high-frequency, pulse width modulated inverter transforms the battery energy into low-distortion, no break, sine wave AC voltage to supply the emergency load.

90% boost tap for line regulation protects against brownouts and conserves batteries for emergencies.
 


 

 True "no break" power to loads
 
 Digitally generated sine wave output
 
 Low input current distortion
 
 98% efficiency on line
 
 Up to 150% momentary overload capacity
 
 Surge and transient protection circuitry
 
 50,000 RMS symmetrical ampere short-circuit rating
 
 Inverter load versatility -- lighting (including fluorescent, incandescent, HID fixtures with self-ballasted lamps, electronic or power-factor corrected ballasts), fire, security, communication systems and other critical loads
 
 Provides computer and network backup
 
 Microprocessor control allows completely automatic self-diagnostic operation to warn of potential problems
 
 Password protected
 
 Automatic self-testing and test logging as required by code
 
 Automatic logging of last 25 alarms and inverter events
 
 2-line x 40-character digital display
 
 Inverter communication -- intelligent, two-way communication capability provided through the system’s RS232 terminal
 
 Built-in backfeed relay to protect personnel from potential shock hazard
 
 Standard 90-minute battery runtime (optional runtimes available)
 
 Load flexibility and reliability -- use of a building’s existing lighting elements for emergency reduces the likelihood of unknown lamp failure
 
 No additional backup systems to maintain or test
 
 Intelligent, easy-to-use system
 
 Display panel monitors and controls all parameters
 
 Two-year electronics warranty
 
 Batteries carry pro-rata warranty
 
 Only front access required for service
 



Specification:
Input

bulletInput voltage: 120, 208, 240, 277, or 347 VAC +10-15%.
 
bulletOther voltages available on request
 
bulletInput frequency: 60Hz ±3%
 
bulletSynchronizing slew rate: 1 Hz per second nominal
 
bulletInput lightning protection: Meets ANSI 62.41, UL 924 and
 
bulletUL 1778 requirements
 


Output
 


 

 Output voltage: 120, 240, 277, 240/120, 277/120, or 347 VAC.
 
 Other voltages available upon request
 
 Output regulation: (static) ±5% based on a 5% - 100% resistive load
 
 Minimum loading: 5% of rated system capacity
 
 Output distortion: Less than 5% THD linear load
 
 Load power factor: .75 lag to .8 lead
 
 Output frequency: Normally, synchronized to utility, +.05 Hz during emergency
 
 Overload: 150% momentary. 120% for five minutes
 
 Time to transfer to inverter after a utility power failure: No break
 


Battery
 


 

 Battery charger: Automatic with internal diagnostic indicators
 
 Recharge time: 24 hours. Meets UL 924 requirements
 
 Battery protection: Automatic low-battery voltage disconnect.
 
 Automatic restart upon utility return
 
 Battery switch: Also used as battery isolator
 
 Standard battery: S - Sealed lead-calcium 10-year life
 


Optional batteries:
G - Sealed lead-calcium 20-year life
N - Wet nickel-cadmium 25-year life
Battery voltage: 96VDC or 144VDC (system dependent)
Runtimes: 90 minutes standard. Other runtimes available on request
Operating temperature: 0°C to 40°C (32°F to 104°F)
Relative humidity: 95% non-condensing

Note: Battery performance rated at 25°C (77°F)

 

Home - 9 Power Problems - Problems with Power - APC - Powerware - MinuteMan - MGE - Liebert - Batteries - Chargers / Rectifiers - Emergency Lighting - Service - Factory Links