UPS Systems

Universal Battery Valve Regulated Lead Acid Batteries Batteries

  Emergency Lighting

Battery chargers, rectifiers, dc power systems by SENS Battery Chargers

Click for more about the Battery Rack™ 20 with Tester (Grey) Battery Storage

Specials!

Service

Lease Info

 

 

CRITICAL AREA LIGHTING & EQUIPMENT
  Series Features UPS

bulletContinuously on Inverter
bulletSine Wave Output
bulletSolid State
bulletInternal Component Redundancy
bulletMagnetic Ballas †

UPS Series Inverters offer solutions to these typical utility power problems

bulletBrownouts
bulletUndervoltage Conditions
bulletPower Outages <1.5 Hours
bulletPower Outages greater than or equal to 1.5 Hours

 

 

 

 

 

 

 

 

bullet90 Minutes Run Time for Uninterruptible Power to Emergency Lighting Circuit
bulletBattery Circuit Breaker
bullet3 Battery Types:
(S ~ Sealed Lead Calcium)
(L ~ Refillable Lead Acid)
(N ~ Refillable NiCad)
 

bulletMeets or Exceeds UL 924
bulletHigh Lighting Immunity
bullet30 Minutes MTTR
bullet140 dB transverse mode noise attenuation
bulletLow input current distortion 6%
bulletFront panel access
bullet24 Hour Service Hot Line Label in each unit Access from anywhere in the USA
 
 

System Operation

1

An input high isolation ferroresonant transformer provides power to a solid state rectifier, which in turn, creates a regulated DC supply. This supply provides the power requirements for the continuously running inverter.
 

 

 

2

An input high isolation ferroresonant transformer provides power to a solid state rectifier/charger, which in turn, creates a regulated DC supply. This supply charges the battery
 

3

A sealed maintenance free battery is provided to maintain power to the inverter during a mains failure. The battery is fitted with a suitably rated fuse to provide overload and short circuit protection.
 

4

A ferroresonant transistorized static inverter transforms the DC voltage coming from either the rectifier or the battery into regulated AC voltage to supply the critical load.
5
An electro/mechanical automatic bypass switch connects the load normally to the inverter. In the case of inverter failure or voluntary shutdown, the load is connected to the utility.
 
 

High Efficiency
Uninterruptable Power Supply

  Ferroresonant technology reduces circuit complexity which in turn, doubles the factory warranty. The inverter utilizes internal transistor redundancy which will allow up to 20% of the power switching transistors to fail and still provide full load output power. This combination achieves a reliability record envied within the industry. Units are floor-mounted, force cooled UPS systems, with front access for servicing. Cabinets contain air filters and knockouts for interwiring with BX, Romex, or Conduit. The internal module consists of a battery charger, AC-DC converter, DC-AC inverter, and batteries. Above 1.5kVA, a separate battery cabinet is supplied.
 

Operational Diagram

 

 

UPS
Series

 

S
Battery Type
(S ~ Sealed)

 

120
Input AC
Line Voltage

 

120
Output AC
Voltage

 

90
Battery Run Time

 

-CFA
Options

 

Mechanical Specifications

Model Number
kVA
Rating
Max Util
Input
Current
System
Efficiency
%
Heat
Loss
BTU's
Inverter Cabinet Dimension
Inverter
Weight
lbs.
(A)
Width
Inches
(B)
Height
Inches
(C)
Depth
Inches
UPSS-1000-120-120-90
1
17
75
900
42
50
12
675
UPSS-1500-120-120-90
1.5
25
75
1300
42
62
12
950
UPSS-3000-120-120-90
3
50
75
2700
42
62
19
775
UPSS-4500-120-120-90
4.5
75
75
4000
42
70
19
885
UPSS-6000-120-120-90
6
100
75
5500
42
70
19
1005
UPSS-7500-120-120-90
7.5
125
75
6800
42
70
19
1175
UPSS-10000-120-120-90
10
166
75
9000
42
70
19
1225
 

Mechanical Specifications Continued

Model Number
Battery
VDC
Battery
Ampers
Battery
Run Time
Minutes
Battery Cabinet Dimension
No. of
Battery
Cabs.
Battery
Cabinet
NetWt.
lbs.
(D)
Width
Inches
(E)
Height
Inches
(F)
Depth
Inches
UPSS-1000-120-120-90
48
28
90
~
~
~
~
~
UPSS-1500-120-120-90
48
43
90
~
~
~
~
~
UPSS-3000-120-120-90
48
85
90
42
50
19
1
811
UPSS-4500-120-120-90
48
128
90
42
62
19
1
1271
UPSS-6000-120-120-90
48
170
90
42
62
19
1
1566
UPSS-7500-120-120-90
48
213
90
42
70
19
1
1820
UPSS-10000-120-120-90
60
227
90
42
62
19
2
1260
 

Electrical Specifications

Input
Output
Standard Voltage: 120 VAC +/-20%. Other voltages available on request.

Power Walk In: 2 cycles, which limits the inrush current from the utility to 200% maximum.

Frequency: 60Hz +/-5%. (50Hz available upon request.)

Synchronizing Slew Rate: 1 Hz per second nominal.

I/O Noise Reduction: 140dB transverse mode.

Input Current: 6% at full load low line.

Standard Voltage: 120 VAC.

Load Power Factor: .75 lag to .9 lead.

Frequency: Normally, synchronized to utility, +/-.05% during emergency (50 Hz available upon request)

Regulation (Static): Input variations +/- 1%, load current change +/-2%, battery+/-2%.

Regulation (Dynamic): +/-6% for a +/-25% load step change. +/-12% for a 50% load step change, recovery within 3 cycles.

Distortion: 5% THD linear load..

Overload: 130% for 5 min.

Transfer Time: None, 0ms transfer time. True-On-Line System.

 

Electrical Specifications Continued

Battery
Physical
Types:
S ~ Sealed Lead Calcium
L ~ Refillable Lead Acid
N ~ Refillable NiCad

Standard Battery: Sealed lead calcium.

Charger: Automatic boost charge (equalize) is applied with a solid-state timer for 24 hrs. approximately every 3 months. Trickle LED mode indicators supplied on each charger..

Recharge Time: 24 Hours.

Protection: Auto low battery voltage disconnect Automatic restart upon utility return.

Circuit Breaker: Also used as a battery isolator.

Optional Run Time: Extended run times available upon request, consult Factory.

Relative Humidity: 95% non- condensing.

Operating Temperature: 32°F-104° F. Continuous operation at high or low ambient temperatures may affect battery life and run time.

Front Panel Controls Group: Battery DC voltmeter. Output AC voltmeter. Utility Power OK indicator. Battery charge ammend System Test Switch. Hi-charge indicator.

Automatic Bypass Switch: Upon an inverter failure, the AC utility automatically transfers to the load with a mechanical switch within 3 seconds. (Fast solid-state 2ms, switching upon request. SBYP Optional).

 

 

 

Home - 9 Power Problems - Problems with Power - APC - Powerware - MinuteMan - MGE - Liebert - Batteries - Chargers / Rectifiers - Emergency Lighting - Service - Factory Links