800-706-7009
| |

|
QUIK-CHEK
REMOTE CONTROL TESTING
- Verifies operation of lamps, charger & battery
- Hand held transmitter ~ 1' - 50' range
- Field adjustable time delay ~ 1-90 minutes
- U.S. Patent #5148158, Canadian Patent #1320246
|

Shown in Standard White Finish
Providing a clean look in commercial facilities, the RQ Series combines
the advantage of a fully recessed unit with maximum remote head capability.
also included is Quik-ChekTM,
our exclusive remote testing feature for emergency lights.

|
|

|
- Integrated Solid State System
- Multi-Rate, Controlled, Automatic Charger ~ No manual battery
recycling
- Lock Out (Automatic Battery Connect)
- Low Voltage Battery Cutoff
- Brownout Sensitivity
- Fused AC Input & DC Output Circuit Protection
- Dual Voltage Transformer for
120/277 VAC Operation
- Maximum Input Rating
120VAC, 60 Hz, 0.35 Amps
277VAC, 60 Hz, 0.15 Amps
|
|

|
- Par-36 Sealed Beam Lamps
STD Lamp: See Unit Information
|
|

|
- Sealed Lead Calcium Battery
- 6 or 12 Volt Operation
- Maintenance Free
|
|

|
- Fully Recessed Styling
- Designed for use in 2 ft. grid (T-bar) Drop Ceilings
- Easy Access Battery Panels
- 20 Gauge Steel Housing
- Unit Mounts up to 4 Lamp Heads
- White Powder Coat Finish
- Test Switch
- Red (Power On) & Green (Trickle Charge) LED Indicators
- New York City Approved/Calendar #38236
- UL Listed
|
Unit Information (Watts per hour)
|
Model #
|
STD LAMP WATT
|
1.5
|
2
|
3
|
4
|
5
|
6
|
7
|
8
|
Replacement Battery
|
| 2RQ6S16 |
8
|
45
|
36
|
20
|
15
|
12
|
10
|
9
|
8
|
(2) S68
|
| 2RQ6S20 |
8
|
64
|
50
|
32
|
24
|
19
|
16
|
14
|
12
|
(2) S610
|
| 2RQ6S36 |
8
|
100
|
75
|
50
|
38
|
30
|
25
|
21
|
18
|
(1) S636
|
| H2RQ12S7*** |
12
|
36
|
27
|
18
|
14
|
11
|
9
|
8
|
7
|
(2) S68
|
| H2RQ12S10*** |
12
|
60
|
45
|
36
|
23
|
18
|
15
|
13
|
11
|
(2) S610
|
| H2RQ12S15*** |
12
|
100
|
75
|
50
|
38
|
30
|
25
|
21
|
18
|
(1) S1215
|
***Chicago Code Approved
Illumination is rated to 87.5% of nominal system voltage and
recharge to full capacity within 24 hours.
NEC requires 1.5 hours of emergency illumination.
Factory Options
| -OW |
Designer Offwhite Finish |
| -BLK |
Black Finish |
| -PA |
Plenum Construction |
| -** |
Special Lamp
Wattage |
Ordering Information
|
H
Halogen Lamp Prefix
|
2
Lamp Heads on Unit
|
RQ
Series
|
6
DC Battery Voltage
|
S
Battery Type
(S~Sealed)
|
16
Battery
Amp/Hour
|
-PA
Options
|
|