INVERTER OPTIONSSUPERVISORY
OPTIONS
INPUT/OUTPUT OPTIONS
ALARMS & ELECTRONIC OPTIONS
BATTERY OPTIONS
START UP SERVICE
|
|
Letter
Code
|
Avail. On Model(s)
|
Local Or Remote |
Description
|
|
RMP
|
ALL
|
Remote
|
Remote meter
panel. Two lamp indicators, two meters (AC output volts and DC Battery
volts). Indicators may vary from model to model. Maximum distance varies
from model to model |
|
PFM
|
IPS,FTS,UPS
|
Either
|
Power flow monitor panel with up
to 30 LED display lights. Block diagram shows operating status and power
flow of system. |
|
IAM
|
ALL
|
Either
|
AC Input
ammeter measures AC input current to system. Remote operation up to 50 feet.
Must have multiple meters with MPH options. |
|
IVM
|
ALL
|
Either
|
AC Input voltmeter measures AC
input voltage to system. Must have multiple meters for system with MPH
options. |
|
FM
|
ALL
|
Either
|
AC input
and/or AC output require frequency meter (specify). Must have multiple
meters for systems with MPH options. |
|
DCA
|
IPS,FTS,UPS
|
Either
|
DC ammeter measures battery
output DC current. Remote operation up to 50 feet. |
|
DMP
|
FTS
|
Either
|
Digital meter
panel. 3.5 LCD display. Switch selectable, shows: [1] input volts; [2]
battery current; [3] battery volts; [4] output frequency; [5] output amps;
[6] output volts. |
|
LCM
|
IPS,FTS,UPS
|
Either
|
AC output ammeter measures AC
output current of system. Remote operation up to 50 feet. Must have multiple
meters with MPH options. |
|
DL
|
IPS,DCS,UPS
|
Local
|
Lighted
indicator to show battery charger status of float charge. |
|
SPC
|
ALL
|
Local
|
Special color cabinet requires
either FED-STD 595 color number or one gallon paint and compatible solvent
per cabinet. Specify color for screening (where applicable). Big Beam can
paint or coat any finish on cabinets provided the volatile organic compound
(VOC) for either finish or primer does not exceed 3.5 per pounds or gallon
(3,500 parts per billion by weight or gallon). |
|
SPR
|
ALL
|
Remote
|
Special color
remote panel requires either FED-STD 595 color number or two quarts paint
and compatible solvent per panel. Specify color for screening (where
applicable). |
|
KSW
|
ALL
|
Either
|
Key switch-system on/off. |
|
Letter
Code
|
Avail. On Model(s)
|
I/O Circuit*
|
I/O Circuit* |
Description
|
|
ICB
|
IPS,DCS,UPS
|
Input
|
One
|
Input circuit breaker for AC protection or service disconnect. Mounted
inside cabinet. Price for voltage, current rating, and number of poles. |
|
OCB
|
ALL
|
Output
|
Varies by Model
|
Output circuit
breaker for load protection. Mounted inside cabinet. Priced for voltage,
current rating, and number of poles. Protection for normally on and/or off
loads. |
|
ISO
|
ALL
|
Input
Output
|
Input
Output
|
Isolation
transformer required when line-to-line voltage on multi-phase inputs are
different than the output voltage. Some systems may require external
enclosure for this transformer. Consult factory. |
|
AUTO
|
ALL
|
Input
Output
|
Input or Output or both
|
Auto
transformer required when input voltage to neutral is different than the
output voltage to neutral. Some systems may require external enclosure for
this transformer. Consult factory. |
|
MPH-1
|
UPS
|
Bypass Mode
|
One
|
Used for
powering dual voltage loads in both normal and emergency operations. |
|
MPH-2
|
IPS
|
Transfer Mode
|
One
|
Used for
balancing single-phase lighting loads on a three-wire distribution service
during the normal operating mode. In the emergency mode all loads receive
normal voltage from a single-phase source. |
|
MPH-3
|
IPS
|
Transfer Mode
|
One
|
Refer to MPH-2
above. Used for balancing single-phase lighting loads on three=phase
distribution in the normal operating mode. |
|
MBYP
|
FTS,UPS
|
Transfer Bypass/ Mode
|
One
|
Allows
maintenance personnel to easily bypass and isolate system from the AC source
and load. |
| * Voltage must be
specified |
|
ALARMS & ELECTRONIC OPTIONS
|
|
Letter
Code
|
Avail. On Model(s)
|
Local Or Remote
|
Description
|
|
CFA
|
ALL
|
Either
|
Low or high battery voltage alarm and/or charger failure. |
|
CFA-FL
|
ALL
|
Either
|
Same as above,
with flashing indicator. |
|
SBYP
|
UPS
|
Local
|
Hi-speed
bypass circuit. Requires one input and one auto transformer for 3-wire
voltage systems. |
|
OTA*
|
ALL
|
Either
|
Output fuse
and/or breaker alarm with audible indicator. Order [1] OTA per OCB (per
pole). |
|
OMA*
|
ALL
|
Either
|
Audible and
visual indication of system failure. |
|
HTA*
|
ALL
|
Either
|
Audible and
visual indication of high temperature in electronic cabinet. |
|
-Hz
|
ALL
|
Local
|
Input and
Output frequency other than 60 Hz. Specify. |
|
-V
|
ALL
|
Local
|
Input and
Output voltage other than standard. Specifyvv |
|
ADA
|
ALL
|
Local
|
Dual channel diagnostic monitor of system
operation. If a problem occurs, will automatically dial up to 10 numbers per
channel and announce the alarm problem verbally to person answering phone.
External computer not required. Requires EWA alarm option. |
|
ATS
|
FTS,UPS
|
Local
|
Automatic
transfer switch provides unattended switching from a primary input power
source to a secondary power source (Ex. Utility to AC Generator) after the
primary source fails or goes below specified minimums. Secondary source is
not connected until the power is at the proper voltage and frequency. Relay
contact provided for automatic generator starting. |
|
VTD
|
IPS,FTS,UPS
|
Local
|
Variable time delay, delays
transfer back to utility after a power failure. Three choices: [1] 3-300
seconds; [2] 1-10 seconds; [3] 9-900 seconds. |
|
B232
|
ALL
|
Local std,
remote via modem
|
Provides
local/remote system diagnostics via an on-board microprocessor. Critical
system parameters are sent via direct connect RS-232-C port or modem connect
via telephone line. External computer or terminal required for local
connect. For modem connect version, a dedicated telephone line or extension
must be available during installation. |
|
LDD
|
ALL
|
Either
|
Direct connect long distance
driver (up to 10 miles) with BB232. |
|
RSS
|
ALL
|
Either
|
Rotary
selector switch used with LDD option for directly connecting 20 to 30 remote
BB232 modules into one connector. |
|
IFA
|
IPS,FTS,UPS
|
Either
|
Inverter Failure Alarm, visual
alarm on front panel or remote, indicates loss of inverter. |
|
EWA
|
ALL
|
Either
|
Early warning
alarm. When battery is approaching end of charge during prolonged utility
power failure. Alerts user to perform orderly system shutdown. |
|
FCH
|
IPS,FTS,UPS
|
Local
|
Fast recharge (reduces charge
time). |
|
UFA
|
ALL
|
Either
|
Utility
failure alarm. Audible and visual alarm indicates loss of utility power. |
| * Ring-Back
available. Ring-Back is an audible alarm silence switch which allows user to
silence alarm prior to correcting the fault. When the fault condition is
corrected the alarm signals again, reminding the maintenance personnel to
reset the alarm for the next fault condition. |
|
Letter
Code
|
Avail. On Model(s)
|
Local Or Remote
|
Description
|
|
ELD
|
ALL
|
Either
|
Electrolyte level detector with audible and visual alarm.
Vented batteries only. |
|
ELD-FL
|
ALL
|
Either
|
Same as
above, with flashing indicator. |
|
BEX
|
ISP,FTS,UPS
|
Local
|
Battery
exerciser. Simulates power failure conditions for 10 min. every 30 days. |
|
Letter
Code
|
Avail. On Model(s)
|
Arrival Time
|
Advance Notice
|
|
FPS-2
|
ALL
|
+12 Hours ~ U.S.A. +24 Hours ~ International
|
2 Wks
|
|
FPS-3
|
ALL
|
+24 Hours ~ U.S.A. +48 Hours ~ International
|
3 Wks
|
|
FPS-4
|
ALL
|
+48 Hours ~ U.S.A. +7 Days ~ International
|
4 Wks
|
| This service is
recommended for large systems and all three-phase systems. Big Beam
Emergency Systems, Inc. can provide this service with factory personnel for
any start-up and/or turn-on. Call 815/459-6143 for assistance. This service
is for start-up or turn-on ONLY. For electrical installation, consult
factory |
|