INVERTER OPTIONS

SUPERVISORY OPTIONS
INPUT/OUTPUT OPTIONS
ALARMS & ELECTRONIC OPTIONS
BATTERY OPTIONS
START UP SERVICE

 
SUPERVISORY OPTIONS
Letter
Code
Avail. On Model(s)

Local Or Remote

Description
RMP
ALL
Remote
Remote meter panel. Two lamp indicators, two meters (AC output volts and DC Battery volts). Indicators may vary from model to model. Maximum distance varies from model to model
PFM
IPS,FTS,UPS
Either
Power flow monitor panel with up to 30 LED display lights. Block diagram shows operating status and power flow of system.
IAM
ALL
Either
AC Input ammeter measures AC input current to system. Remote operation up to 50 feet. Must have multiple meters with MPH options.
IVM
ALL
Either
AC Input voltmeter measures AC input voltage to system. Must have multiple meters for system with MPH options.
FM
ALL
Either
AC input and/or AC output require frequency meter (specify). Must have multiple meters for systems with MPH options.
DCA
IPS,FTS,UPS
Either
DC ammeter measures battery output DC current. Remote operation up to 50 feet.
DMP
FTS
Either
Digital meter panel. 3.5 LCD display. Switch selectable, shows: [1] input volts; [2] battery current; [3] battery volts; [4] output frequency; [5] output amps; [6] output volts.
LCM
IPS,FTS,UPS
Either
AC output ammeter measures AC output current of system. Remote operation up to 50 feet. Must have multiple meters with MPH options.
DL
IPS,DCS,UPS
Local
Lighted indicator to show battery charger status of float charge.
SPC
ALL
Local
Special color cabinet requires either FED-STD 595 color number or one gallon paint and compatible solvent per cabinet. Specify color for screening (where applicable). Big Beam can paint or coat any finish on cabinets provided the volatile organic compound (VOC) for either finish or primer does not exceed 3.5 per pounds or gallon (3,500 parts per billion by weight or gallon).
SPR
ALL
Remote
Special color remote panel requires either FED-STD 595 color number or two quarts paint and compatible solvent per panel. Specify color for screening (where applicable).
KSW
ALL
Either
Key switch-system on/off.

 

INPUT/OUTPUT OPTIONS
Letter
Code
Avail. On Model(s)
I/O Circuit*

I/O Circuit*

Description
ICB
IPS,DCS,UPS
Input
One
Input circuit breaker for AC protection or service disconnect. Mounted inside cabinet. Price for voltage, current rating, and number of poles.
OCB
ALL
Output
Varies by Model
Output circuit breaker for load protection. Mounted inside cabinet. Priced for voltage, current rating, and number of poles. Protection for normally on and/or off loads.
ISO
ALL
Input
Output
Input
Output
Isolation transformer required when line-to-line voltage on multi-phase inputs are different than the output voltage. Some systems may require external enclosure for this transformer. Consult factory.
AUTO
ALL
Input
Output
Input or Output or both
Auto transformer required when input voltage to neutral is different than the output voltage to neutral. Some systems may require external enclosure for this transformer. Consult factory.
MPH-1
UPS
Bypass Mode
One
Used for powering dual voltage loads in both normal and emergency operations.
MPH-2
IPS
Transfer Mode
One
Used for balancing single-phase lighting loads on a three-wire distribution service during the normal operating mode. In the emergency mode all loads receive normal voltage from a single-phase source.
MPH-3
IPS
Transfer Mode
One
Refer to MPH-2 above. Used for balancing single-phase lighting loads on three=phase distribution in the normal operating mode.
MBYP
FTS,UPS
Transfer Bypass/ Mode
One
Allows maintenance personnel to easily bypass and isolate system from the AC source and load.
* Voltage must be specified

 

ALARMS & ELECTRONIC OPTIONS
Letter
Code
Avail. On Model(s)
Local Or Remote
Description
CFA
ALL
Either
Low or high battery voltage alarm and/or charger failure.
CFA-FL
ALL
Either
Same as above, with flashing indicator.
SBYP
UPS
Local
Hi-speed bypass circuit. Requires one input and one auto transformer for 3-wire voltage systems.
OTA*
ALL
Either
Output fuse and/or breaker alarm with audible indicator. Order [1] OTA per OCB (per pole).
OMA*
ALL
Either
Audible and visual indication of system failure.
HTA*
ALL
Either
Audible and visual indication of high temperature in electronic cabinet.
-Hz
ALL
Local
Input and Output frequency other than 60 Hz. Specify.
-V
ALL
Local
Input and Output voltage other than standard. Specifyvv
ADA
ALL
Local
Dual channel diagnostic monitor of system operation. If a problem occurs, will automatically dial up to 10 numbers per channel and announce the alarm problem verbally to person answering phone. External computer not required. Requires EWA alarm option.
ATS
FTS,UPS
Local
Automatic transfer switch provides unattended switching from a primary input power source to a secondary power source (Ex. Utility to AC Generator) after the primary source fails or goes below specified minimums. Secondary source is not connected until the power is at the proper voltage and frequency. Relay contact provided for automatic generator starting.
VTD
IPS,FTS,UPS
Local
Variable time delay, delays transfer back to utility after a power failure. Three choices: [1] 3-300 seconds; [2] 1-10 seconds; [3] 9-900 seconds.
B232
ALL
Local std,
remote via modem
Provides local/remote system diagnostics via an on-board microprocessor. Critical system parameters are sent via direct connect RS-232-C port or modem connect via telephone line. External computer or terminal required for local connect. For modem connect version, a dedicated telephone line or extension must be available during installation.
LDD
ALL
Either
Direct connect long distance driver (up to 10 miles) with BB232.
RSS
ALL
Either
Rotary selector switch used with LDD option for directly connecting 20 to 30 remote BB232 modules into one connector.
IFA
IPS,FTS,UPS
Either
Inverter Failure Alarm, visual alarm on front panel or remote, indicates loss of inverter.
EWA
ALL
Either
Early warning alarm. When battery is approaching end of charge during prolonged utility power failure. Alerts user to perform orderly system shutdown.
FCH
IPS,FTS,UPS
Local
Fast recharge (reduces charge time).
UFA
ALL
Either
Utility failure alarm. Audible and visual alarm indicates loss of utility power.
* Ring-Back available. Ring-Back is an audible alarm silence switch which allows user to silence alarm prior to correcting the fault. When the fault condition is corrected the alarm signals again, reminding the maintenance personnel to reset the alarm for the next fault condition.

 

BATTERY OPTIONS
Letter
Code
Avail. On Model(s)
Local Or Remote
Description
ELD
ALL
Either
Electrolyte level detector with audible and visual alarm. Vented batteries only.
ELD-FL
ALL
Either
Same as above, with flashing indicator.
BEX
ISP,FTS,UPS
Local
Battery exerciser. Simulates power failure conditions for 10 min. every 30 days.

 

START UP SERVICE
Letter
Code
Avail. On Model(s)
Arrival Time
Advance Notice
FPS-2
ALL
+12 Hours ~ U.S.A. +24 Hours ~ International
2 Wks
FPS-3
ALL
+24 Hours ~ U.S.A. +48 Hours ~ International
3 Wks
FPS-4
ALL
+48 Hours ~ U.S.A. +7 Days ~ International
4 Wks
This service is recommended for large systems and all three-phase systems. Big Beam Emergency Systems, Inc. can provide this service with factory personnel for any start-up and/or turn-on. Call 815/459-6143 for assistance. This service is for start-up or turn-on ONLY. For electrical installation, consult factory

Home - 9 Power Problems - Problems with Power - APC - Powerware - MinuteMan - MGE - Liebert - Batteries - Chargers / Rectifiers - Emergency Lighting - Service - Factory Links

 Contact Us

Power Factor Inc.

2526 Manana Dr – Suite 102 – Dallas – Texas – 75220

NO DISSATISFIED CUSTOMERS!

Since 1995

While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.