Back Up Next Home Batteries  UPS Technology Emergency Lighting Battery Chargers Factory Links Contact Us Buy Batteries Online

Established 1996                              Call us 800-706-7009

.
• Home • Big Beam Batteries • Big Beam Central Inverter Systems • Big Beam Emergency Lighting • Big Beam Exit Signs • Special Use Exit Signs • Big Beam Warranty Info • New Products •

.

 

Click here to Buy batteries online

Batteries
Eaton Showcase
UPS Technology
Emergency Lighting
Battery Chargers
TVSS
9 Power Problems
Olight Flashlights
Problems with Power
Factory Links
Contact Us

DCS Series
FTS Series
Inverter Options
IPS Series
UPS Series

800-706-7009

 

A+ Rating with the Better Business Bureau

 

HIGH INTENSITY DISCHARGE (HID) LIGHTING
  Series Features FTS

  • Continuously On PWM Inverter
  • Sine Wave Output
  • Internal Component Redundancy
  • 90% Efficiency
  • 50% Overload Capacity
  • Input Circuit Breaker
  • Output Circuit Breaker

FTS Series Inverters offer solutions to these typical utility power problems

  • Brownouts
  • Undervoltage Conditions
  • ± Voltage Transients less than or equal to 5 µsec.
  • Power Outages <1.5 Hours
  • Overvoltage Conditions
  • Severe Transverse Mode Noise on Power Line
  • Severe ± Voltage Transient less than or equal to 4ms
  • Severe Common Mode Noise on Power Line
  • Power Outages greater than or equal to 1.5 Hours

 

 

 

 

 

 

 

 

  • 90 Minutes Run Time for Uninterruptible Power to Emergency Lighting Circuit
  • Battery Circuit Breaker
  • 3 Battery Types:
    (S ~ Sealed Lead Calcium)
    (L ~ Refillable Lead Acid)
    (N ~ Refillable NiCad)
 

  • Digital Metering (7.5 kVA and above)
  • UL 924 Listed
  • 80 dB transverse mode noise attenuation
  • 120 dB common mode noise attenuation
  • Low input current distortion 6%
  • Front panel access
  • 24 Hour Service Hot Line Label in each unit Access from anywhere in the USA.
 
 

System Operation

1

A solid state rectifier/charger transforms the incoming mains into a regulated DC supply charging the battery.
 

 

 

2

A battery is provided to maintain power to the inverter. The battery is fitted with a suitably rated circuit breaker/fuse to provide overload and short circuit protection and also allows isolation from the UPS for maintenance purposes.
 

3

A continuously running pulse width modulated transistorized static inverter transforms the battery energy into a loss distortion, no-break, sine wave, AC voltage to supply the critical load.
 

4

A ferroresonant voltage regulating transformer filters out surges, spikes, electrical noise, lightning spikes, brownouts, and blackouts.
 
 

High Efficiency
On Line / No Break

  Be ready for virtually any emergency with this Uninterruptible Power System. This pulse width modulated inverter is continuously on, utilizing internal transistor redundancy which allows up to 20% of the power switching transistors to fail and still provide “full load output power”. The AC-IN to AC-OUT operating efficiency is typically 90%, well above a typical on line UPS. The internal construction of each cabinet consists of an AC to DC battery charger, DC to AC inverter and energy storage transformer, and either Sealed Lead Calcium, Refillable Lead Acid, or Refillable Nickel Cadmium Batteries.
 

Operational Diagram

 

 

FTS
Series

 

S
Battery Type
(S ~ Sealed)

 

120
Input AC
Line Voltage

 

120
Output AC
Voltage

 

90
Battery Run Time

 

-ISO
Options

 

Mechanical Specifications

Model Number
kVA
Rating
Max Util
Input
Current
System
Efficiency
%
Heat
Loss
BTU's
Inverter Cabinet Dimension
Inverter
Weight
lbs.
(A)
Width
Inches
(B)
Height
Inches
(C)
Depth
Inches
FTSS-1500-120-120-90
1.5
20
90
550
42
50
19
590
FTSS-3000-120-120-90
3
40
90
1100
42
62
19
900
FTSS-5000-120-120-90
5
65
90
1800
42
62
19
1150
FTSS-7500-120-120-90
7.5
75
90
2800
42
50
19
980
FTSS-10000-120-120-90
10
100
90
3700
42
50
19
1100
FTSS-12500-120-120-90
12.5
130
90
4700
42
50
19
1100
FTSS-16700-120-120-90
16.7
170
90
6300
42
50
19
1100

Contact the factory for exact specifications for use with motors and/or a non-synchronous transfer switches. 220/380 or 240/415 VAC, 50 Hz available.
 

Mechanical Specifications Continued

Model Number
Battery
VDC
Battery
Ampers
Battery
Run Time
Minutes
Battery Cabinet Dimension
No. of
Battery
Cabs.
Battery
Cabinet
NetWt.
lbs.
(D)
Width
Inches
(E)
Height
Inches
(F)
Depth
Inches
FTSS-1500-120-120-90
96
20
90
~
~
~
~
~
FTSS-3000-120-120-90
96
40
90
~
~
~
~
~
FTSS-5000-120-120-90
96
67
90
~
~
~
~
~
FTSS-7500-120-120-90
120
83
90
42
50
19
1
1040
FTSS-10000-120-120-90
120
110
90
42
50
19
1
1520
FTSS-12500-120-120-90
120
139
90
42
70
19
1
2475
FTSS-16700-120-120-90
120
184
90
42
50
19
2
1630

Contact the factory for exact specifications for use with motors and/or a non-synchronous transfer switches. 220/380 or 240/415 VAC, 50 Hz available.
 

Electrical Specifications

Input
Output
Standard Voltage: 120 VAC +10%/ -15%. Other voltages available on request.

Power Walk In: 2 cycles, which limits the inrush current from the utility to 125% maximum.

Frequency: 60Hz +/-3%. 50Hz available upon request.

Synchronizing Slew Rate: 1 Hz per second nominal.

Lightning Protection: Up to 10,000V, 320 joules, meets IEEE/ANSI C62.42-45.

I/O Noise Reduction: 80dB transverse mode, 120 dB common mode (common mode not standard on 1.5-5kVA.)

Current Distortion: 6% at full load low line.

Circuit Breaker: For complete system protection.

Standard Voltage: 120 VAC two wire. Other voltages available on request.

Load Power Factor: .75 lag to .9 lead.

Frequency: Normally, synchronized to utility, +/-.05% during emergency (50 Hz available upon request)

Regualtion (Static): Input variations +/- 1%, load current change +/-2%, battery+/-2%.

Regulation (Dynamic): +/-3% for a +/-25% load step change. +/-6% for a 50% load step change, recovery within 3 cycles.

Transfer Time: None, zero transfer time.

Distortion: 5% THD linear load..

Overload: Normal: 150% for 5 min. Emergency: 130% for 5 min.

Circuit Breaker: For complete system protection.

 

Electrical Specifications Continued

Battery
Physical
Types:
S ~ Sealed Lead Calcium
L ~ Refillable Lead Acid
N ~ Refillable NiCad

Charger: Automatic with internal diagnostic indicators. One LED type indicator for float mode and another for high charge mode.

Recharge Time: 24 Hours.

Protection: Auto low battery voltage disconnect.

Circuit Breaker: Also used as a battery isolater.

Optional Run Time: Extended run times available upon request, consult Factory.

Relative Humidity: 95% non- condensing.

Operating Temperature: 32°F-104° F. Continuous operation at high or low ambient temperatures may affect battery life and run time.

Metering: Digital on 7.5-16.7 kVA indicating input voltage, output voltage, output frequency, output current, battery voltage, and battery current, Analog 1.5-5kVA indicating output voltage, battery voltage, charge level.

Controls: On/Off key operated switch on 7.5-16.6 kVA. Internal On/Off switch on 1.5-5kVA. System test switch.

Maintenance: External Bypass switch optional. Used to power load in case of inverter failure or general maintenance. Size of Enclosure: 20H x 16W x 6.5D in. 43 lbs. See options pages.

 

 

 

 

 

Home Batteries  UPS Technology Emergency Lighting Battery Chargers Factory Links Contact Us Buy Batteries Online

Power Factor Inc.

2526 Manana Dr – Suite 102 – Dallas – Texas – 75220

800-706-7009

 Our Goal, NO DISSATISFIED CUSTOMERS!

Since 1995

While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.