Contact Us Toll Free
Buy
batteries on-line

Request Info
UPS Systems
Batteries
Emergency Lighting
Battery
Chargers
Battery Storage
Specials!
Service
Lease Info
| |
|
HIGH INTENSITY DISCHARGE (HID) LIGHTING
|
| |
|
|
1 |
A solid state
rectifier/charger transforms the incoming mains into a regulated DC supply
charging the battery. |
|
2 |
A battery is provided to maintain power to
the inverter. The battery is fitted with a suitably rated circuit
breaker/fuse to provide overload and short circuit protection and also
allows isolation from the UPS for maintenance purposes. |
|
3
|
A continuously running pulse
width modulated transistorized static inverter transforms the battery energy
into a loss distortion, no-break, sine wave, AC voltage to supply the
critical load. |
|
4
|
A ferroresonant voltage
regulating transformer filters out surges, spikes, electrical noise,
lightning spikes, brownouts, and blackouts. |
| |
High Efficiency
On Line / No Break
|
| |
Be ready for virtually any
emergency with this Uninterruptible Power System. This pulse width modulated
inverter is continuously on, utilizing internal transistor redundancy which
allows up to 20% of the power switching transistors to fail and still
provide “full load output power”. The AC-IN to AC-OUT operating efficiency
is typically 90%, well above a typical on line UPS. The internal
construction of each cabinet consists of an AC to DC battery charger, DC to
AC inverter and energy storage transformer, and either Sealed Lead Calcium,
Refillable Lead Acid, or Refillable Nickel Cadmium Batteries. |
|
FTS
Series
|
S
Battery Type
(S ~ Sealed)
|
120
Input AC
Line Voltage
|
120
Output AC
Voltage
|
90
Battery Run Time
|
-ISO
Options
|
Mechanical Specifications
|
| Model Number |
kVA
Rating
|
Max Util
Input
Current
|
System
Efficiency
%
|
Heat
Loss
BTU's
|
Inverter Cabinet Dimension
|
Inverter
Weight
lbs.
|
|
(A)
Width
Inches
|
(B)
Height
Inches
|
(C)
Depth
Inches
|
| FTSS-1500-120-120-90 |
1.5
|
20
|
90
|
550
|
42
|
50
|
19
|
590
|
| FTSS-3000-120-120-90 |
3
|
40
|
90
|
1100
|
42
|
62
|
19
|
900
|
| FTSS-5000-120-120-90 |
5
|
65
|
90
|
1800
|
42
|
62
|
19
|
1150
|
| FTSS-7500-120-120-90 |
7.5
|
75
|
90
|
2800
|
42
|
50
|
19
|
980
|
| FTSS-10000-120-120-90 |
10
|
100
|
90
|
3700
|
42
|
50
|
19
|
1100
|
| FTSS-12500-120-120-90 |
12.5
|
130
|
90
|
4700
|
42
|
50
|
19
|
1100
|
| FTSS-16700-120-120-90 |
16.7
|
170
|
90
|
6300
|
42
|
50
|
19
|
1100
|
Contact the factory for exact specifications for use with motors and/or a
non-synchronous transfer switches. 220/380 or 240/415 VAC, 50 Hz available. |
Mechanical Specifications Continued
|
| Model Number |
Battery
VDC
|
Battery
Ampers
|
Battery
Run Time
Minutes
|
Battery Cabinet Dimension
|
No. of
Battery
Cabs.
|
Battery
Cabinet
NetWt.
lbs.
|
|
(D)
Width
Inches
|
(E)
Height
Inches
|
(F)
Depth
Inches
|
| FTSS-1500-120-120-90 |
96
|
20
|
90
|
~
|
~
|
~
|
~
|
~
|
| FTSS-3000-120-120-90 |
96
|
40
|
90
|
~
|
~
|
~
|
~
|
~
|
| FTSS-5000-120-120-90 |
96
|
67
|
90
|
~
|
~
|
~
|
~
|
~
|
| FTSS-7500-120-120-90 |
120
|
83
|
90
|
42
|
50
|
19
|
1
|
1040
|
| FTSS-10000-120-120-90 |
120
|
110
|
90
|
42
|
50
|
19
|
1
|
1520
|
| FTSS-12500-120-120-90 |
120
|
139
|
90
|
42
|
70
|
19
|
1
|
2475
|
| FTSS-16700-120-120-90 |
120
|
184
|
90
|
42
|
50
|
19
|
2
|
1630
|
Contact the factory for exact specifications for use with motors and/or a
non-synchronous transfer switches. 220/380 or 240/415 VAC, 50 Hz available. |
Electrical Specifications
|
|
Input
|
Output
|
| Standard Voltage: 120 VAC
+10%/ -15%. Other voltages available on request. Power Walk In: 2 cycles,
which limits the inrush current from the utility to 125% maximum.
Frequency: 60Hz +/-3%. 50Hz available upon request.
Synchronizing Slew Rate: 1 Hz per second nominal.
Lightning Protection: Up to 10,000V, 320 joules, meets IEEE/ANSI
C62.42-45.
I/O Noise Reduction: 80dB transverse mode, 120 dB common mode (common
mode not standard on 1.5-5kVA.)
Current Distortion: 6% at full load low line.
Circuit Breaker: For complete system protection. |
Standard Voltage: 120 VAC two
wire. Other voltages available on request.
Load Power Factor: .75 lag to .9 lead.
Frequency: Normally, synchronized to utility, +/-.05% during emergency
(50 Hz available upon request)
Regualtion (Static): Input variations +/- 1%, load current change +/-2%,
battery+/-2%.
Regulation (Dynamic): +/-3% for a +/-25% load step change. +/-6% for a
50% load step change, recovery within 3 cycles.
Transfer Time: None, zero transfer time.
Distortion: 5% THD linear load..
Overload: Normal: 150% for 5 min. Emergency: 130% for 5 min.
Circuit Breaker: For complete system protection. |
Electrical Specifications Continued
|
|
Battery
|
Physical
|
Types:
S ~ Sealed Lead Calcium
L ~ Refillable Lead Acid
N ~ Refillable NiCad
Charger: Automatic with internal diagnostic indicators. One LED type
indicator for float mode and another for high charge mode.
Recharge Time: 24 Hours.
Protection: Auto low battery voltage disconnect.
Circuit Breaker: Also used as a battery isolater.
Optional Run Time: Extended run times available upon request, consult
Factory. |
Relative Humidity: 95% non-
condensing.
Operating Temperature: 32°F-104° F. Continuous operation at high or low
ambient temperatures may affect battery life and run time.
Metering: Digital on 7.5-16.7 kVA indicating input voltage, output
voltage, output frequency, output current, battery voltage, and battery
current, Analog 1.5-5kVA indicating output voltage, battery voltage, charge
level.
Controls: On/Off key operated switch on 7.5-16.6 kVA. Internal On/Off
switch on 1.5-5kVA. System test switch.
Maintenance: External Bypass switch optional. Used to power load in case
of inverter failure or general maintenance. Size of Enclosure: 20H x 16W x
6.5D in. 43 lbs. See options pages. |
|