CENTRAL DC EMERGENCY SYSTEM
  Series Features DCS

  • AC Input - DC Output
  • Output: 12VDC to 120VDC
  • Capacity: 500 Watts to 10,000 Watts
  • Fully Automated Operation
  • Solid State Charger
  • High Efficiency
  • 100 ms Switch Time

DC Central System for:
Emergency Lighting, Fire Alarms, Burglar Alarms, Clutch Releases, Fire Doors, and any load requiring normally-off DC power.

POPULAR OPTIONS:
Output Circuit Breakers

  • Variable Time Delay
  • Remote Diagnostics

 

 

 

 

 

 

 

 

  • 90 Minutes Run Time Standard For Emergency Lighting Longer Run Times Available
  • 3 Battery Types:
    (S ~ Sealed Lead Calcium)
    (L ~ Refillable Lead Acid)
    (N ~ Refillable NiCad)
 

  • LED Indicators
  • Analog Metering
  • Front Door Access
  • 24 Hour Service Hot Line Label in each unit
  • Meets or Exceeds UL924
 
 

Function / Use

  When normal AC power fails, the DCS emergency power system supplies a low DC voltage (12 to 120VDC) at a high capacity (500 to 10,000 Watts) to the critical load. Uses include emergency lighting, fire alarms, burglar alarms, clutch releases, and fire doors. The standard run time is 90 minutes for emergency lighting, but both longer and shorter run times are available for special requirements. The DCS central system eliminates the need for individual emergency lighting power packs by providing a single high capacity unit in one location.

These systems are ideal for operating remote incandescent lighting heads, exit signs, or quartz halogen lamps mounted within H.I.D. fixtures. They can also be used to power high efficiency DC inverter ballasts that are remotely mounted within fluorescent fixtures.

 

 

DCS
Series

 

S
Battery Type
(S ~ Sealed)
(L ~ Refillable Lead Acid)
(N ~ Refillable NiCad)

1000
Output
Watts
 

120
Input AC
Voltage

 

12
Output DC
Voltage

 

90
Battery Run Time

 

-OCB
Options

 

Mechanical Specifications

Model Number
Output
Watts
Output
Voltage
VDC
Max Util
Input
Current
Heat
Loss
BTU's
(A)
Width
Inches
(B)
Height
Inches
(C)
Depth
Inches
Inverter
Weight
lbs.
Battery
Voltage
VDC
Battery
Run Time
Minutes
Shipping
Weight
lbs.
DCSS-500-120-12-90
 
500
12
2
44
32
33
12
180
12
90
255
DCSS-1000-120-12-90
1000
12
2
44
32
33
12
256
12
90
331
DCSS-1500-120-12-90
1500
12
3
88
42
38
12
330
12
90
405
DCSS-2000-120-12-90
2000
12
3
88
42
38
12
438
12
90
513
DCSS-1000-120-24-90
1000
24
3
88
32
33
12
256
24
90
331
DCSS-2000-120-24-90
2000
24
3
88
42
38
12
438
24
90
513
DCSS-3000-120-24-90
3000
24
5
175
42
50
12
582
24
90
657
DCSS-4000-120-24-90
4000
24
5
175
42
50
12
692
24
90
767
DCSS-1500-120-36-90
1500
36
4
132
42
38
12
330
36
90
405
DCSS-3000-120-36-90
3000
36
4
132
42
50
12
574
36
90
649
DCSS-4500-120-36-90
4500
36
8
264
42
50
12
802
36
90
877
DCSS-6000-120-36-90
6000
36
8
264
42
62
19
1028
36
90
1103
DCSS-2000-120-48-90
2000
48
5
175
42
50
12
438
48
90
513
DCSS-4000-120-48-90
4000
48
5
175
42
50
12
718
48
90
793
DCSS-6000-120-48-90
6000
48
10
350
42
62
12
1083
48
90
1158
DCSS-8000-120-48-90
8000
48
10
350
42
50
19
1303
48
90
1378
DCSS-5000-120-120-90
5000
120
12
430
42
50
19
943
120
90
1018
DCSS-10000-120-120-90
10000
120
12
430
42
70
19
1725
120
90
1800
 

Electrical Specifications

Input
Output
Single-Phase: 120VAC standard as shown above, 208, 240, or 277 at 60Hz; 220 or 380 at 50Hz. Other voltages available; contact factory. Standard Output Voltages: 12, 24, 36, 48, 120 VDC.

Current: 5 to 167 amps.

Time to provide DC power after utility power failure: 100ms, standard; faster transfer times available, contact factory.

Output DC voltage range: 2.3 volts per cell max. 1.75 volts per cell min. on lead battery systems, (2 volts per cell nominal). 1.55 volts per cell max. 1.05 volts per cell min. on nickel battery systems 1.2v per cell nominal).

 

Electrical Specifications Continued

Battery
Physical
CHM battery Charger: Automatic 24-hr. boost charge (equalize) is applied for 24-hrs. with a solid-state timer approximately every 3 months. Trickle charge, applied constantly. Internal green, yellow and dual red LED mode indicators supplied on each charger. Automatic low battery voltage disconnect. Automatic restart upon utility return.

Standard Battery: Sealed lead calcium.

Relative Humidity: 95% non- condensing.

Operating Temperature: 32°F-104° F. Continuous operation at high or low ambient temperatures may affect battery life and run time, respectively. See battery warranty sheet for details..

Front Panel Controls Group: Battery DC voltmeter. Input AC voltmeter. Utility power OK indicator. Hi-charge indicator. Battery charge ammeter. System Test Switch.

Options: Breaker distribution panel available. See options pages.

 

 

 

 

 

Home Batteries  UPS Technology Emergency Lighting Battery Chargers Factory Links Contact Us Buy Batteries Online

Power Factor Inc.

2526 Manana Dr – Suite 102 – Dallas – Texas – 75220

800-706-7009

 Our Goal, NO DISSATISFIED CUSTOMERS!

Since 1995

While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.