CSB China Storage Battery XTV12950 XTV-12950  12 Volt 95Ah (Amp Hour) Battery

 

XTV12950
12 V 95.0Ah
XTV12950 battery is specially designed for extreme temperatures (-20 to 50 ℃). Innovative Valve egulated Lead-Acid (VRLA) technology enables a 12-year design life in standby use, or more than 400 cycles at 100% discharge.
 
Download : XTV12950 Spec Sheet -(1.26M)
     
Specification  
Cells Per Unit 6
Voltage Per Unit 12 V
Capacity 95.0Ah@ 10hr-rate to 1.80V per cell @ 25°C (77°F)
Weight (kg) Approx. 32.8 kg(72.31 lbs)
Maximum Discharge current (A) 800A(5sec)
Internal Resistance Approx. Approx. 6.5mΩ
Operating Temperature Range Discharge:-20℃~50℃(-4°F~122°F)
Charge:-20℃~50℃(-4°F~122°F)
Storage:-15℃~40℃(5°F~104°F)
Nominal Operating Temperature Range 25°C ± 3°C (77°F ± 5°F)
Float charging voltage 13.5 to 13.8 VDC/unit Average at 25°C (77°F)
Recommended Maximum Charging current limit 28.5A
Equalization and Cycle Service 14.4 to 15.0 VDC/unit Average at 25°C (77°F)
Self Discharge CSB Batteries can be stored for more than 6 months at 25°C (77°F) Please charge batteries before using. For higher temperatures the time interval will be shorter.
Terminal I2-Thread lead alloy recessed terminal to accept M6/M8 bolt
Container Material PP (UL 94-V0/File E50955)*Flammability resistance
of (UL 94-HB/File E216959) can be available upon request.

 
Dimensions  


 
Constant Current Discharge Characteristics Unit:Amperes (25°C,77°F)
F.V/Time 5MIN 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V 361.00 250.00 191.00 116.00 69.20 41.10 28.30 21.60 17.90 11.90 10.00 5.18
1.67V 319.00 233.00 182.00 114.00 67.80 40.20 28.00 21.50 17.70 11.80 9.79 5.15
1.70V 298.00 223.00 177.00 112.00 67.00 39.90 27.60 21.40 17.60 11.70 9.72 5.13
1.75V 264.00 206.00 169.00 107.00 65.10 38.70 26.90 21.00 17.40 11.60 9.59 5.07
1.80V 240.00 186.00 156.00 101.00 62.70 37.00 26.40 20.70 17.00 11.40 9.50 4.98
1.85V 198.00 166.00 136.00 92.40 58.50 34.70 25.00 19.50 16.30 11.00 9.05 4.79
Constant Power Discharge Characteristics Unit:Watts (25°C,77°F)
F.V/Time 5MIN 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V 3383.00 2525.00 2032.00 1258.00 768.00 457.00 324.00 254.00 209.00 140.00 117.00 60.70
1.67V 3128.00 2400.00 1972.00 1244.00 757.00 451.00 321.00 250.00 207.00 139.00 116.00 60.00
1.70V 3021.00 2330.00 1950.00 1232.00 755.00 448.00 318.00 249.00 206.00 138.00 115.00 59.70
1.75V 2833.00 2186.00 1829.00 1193.00 739.00 437.00 310.00 245.00 204.00 136.00 114.00 59.40
1.80V 2496.00 2029.00 1675.00 1137.00 713.00 419.00 304.00 238.00 198.00 134.00 113.00 58.50
1.85V 2124.00 1804.00 1476.00 1056.00 672.00 398.00 289.00 226.00 189.00 129.00 108.00 56.80

CSB China Storage Battery XTV12950 XTV-12950  12 Volt 95Ah (Amp Hour) Battery CSB China Storage Battery XTV12950 XTV-12950  12 Volt 95Ah (Amp Hour) Battery CSB China Storage Battery XTV12950 XTV-12950  12 Volt 95Ah (Amp Hour) Battery CSB China Storage Battery XTV12950 XTV-12950  12 Volt 95Ah (Amp Hour) Battery CSB China Storage Battery XTV12950 XTV-12950  12 Volt 95Ah (Amp Hour) Battery

 

• XTV1272 • XTV12750 • XTV12850 • XTV12950 •

 

 

 

 

 

Home Batteries  UPS Technology Emergency Lighting Battery Chargers Factory Links Contact Us Buy Batteries Online

Power Factor Inc.

2526 Manana Dr – Suite 102 – Dallas – Texas – 75220

800-706-7009

 Our Goal, NO DISSATISFIED CUSTOMERS!

Since 1995

While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.