• UPS12240 • UPS123606 • UPS123607 • UPS12540 •

CSB China Storage Battery UPS12240 UPS-12240  12 Volt 40WPC (Watts Per Cell) Battery

 

UPS12240
12 V 40.0w/cell
UPS122406 use the latest wafer-thin plate technology to provide optimum high-rate (5-min) performance. With more than 260 cycles at 100% discharge in cycle service, or up to 5 years of standby service.
 
Download : UPS122406 Spec sheet-(1.24M)
     
 
Specification  
Cells Per Unit 6
Voltage Per Unit 12 V
Capacity 40W @ 5min-rate to Watt (1.6V)/cell @25°C (77°F)
Weight (kg) Approx . 1.45 kg(3.2 lbs)
Maximum Discharge current (A) 100/130A(5sec)
Internal Resistance Approx. Approx . 32mΩ
Operating Temperature Range Discharge:-15℃~50℃(5°F~122°F)
Charge:-15℃~40℃(5°F~104°F)
Storage:-15℃~40℃(5°F~104°F)
Nominal Operating Temperature Range 25°C ±3°C (77°F ± 5°F)
Float charging voltage 13.5 to 13.8 VDC/unit Average at 25°C (77°F)
Recommended Maximum Charging current limit 2.0A
Equalization and Cycle Service 14.4 to 15.0 VDC/unit Average at 25°C (77°F)
Self Discharge CSB Batteries can be stored for more than 6 months at 25°C (77°F) Please charge batteries before using. For higher temperatures the time interval will be shorter.
Terminal F1/F2-Faston Tab 180/250
Container Material ABS(UL 94-HB/File E50263)*Flammability resistance of
(UL 94-V0/File E88637) can be available upon request.

 
Dimensions  


 
Constant Current Discharge Characteristics Unit:Amperes (25°C,77°F)
F.V/Time 2MIN 3MIN 4MIN 5MIN 6MIN 7MIN 8MIN 10MIN 15MIN 20MIN 30MIN 60MIN 90MIN
1.60V 40.13 31.22 25.82 23.33 20.65 18.58 16.90 14.36 10.40 8.21 5.89 3.42 2.43
1.67V 36.01 28.59 24.43 22.23 19.77 17.82 16.37 14.14 10.26 8.06 5.79 3.40 2.39
1.70V 33.73 27.39 23.60 21.28 19.01 17.22 16.00 13.90 10.18 7.94 5.74 3.39 2.36
1.75V 30.02 24.98 22.10 20.14 18.17 16.53 15.43 13.49 9.91 7.81 5.64 3.37 2.35
1.80V 26.51 22.52 20.16 18.75 17.06 15.71 14.50 12.70 9.53 7.60 5.53 3.31 2.33
1.85V 23.70 20.21 18.22 17.22 15.78 14.48 13.37 11.57 8.82 7.09 5.23 3.19 2.27
Constant Power Discharge Characteristics Unit:Watts (25°C,77°F)
F.V/Time 2MIN 3MIN 4MIN 5MIN 6MIN 7MIN 8MIN 10MIN 15MIN 20MIN 30MIN 60MIN 90MIN
1.60V 385.72 312.81 273.07 244.19 218.41 196.91 179.44 156.99 115.02 92.63 68.20 40.57 29.19
1.67V 355.04 300.80 261.98 232.13 209.54 192.00 176.25 155.19 113.96 91.36 67.26 40.38 28.79
1.70V 346.16 288.79 257.80 227.89 206.19 187.62 173.35 153.42 113.18 90.11 66.65 40.33 28.53
1.75V 320.83 274.33 245.63 221.17 201.50 183.35 169.93 148.55 110.53 88.87 65.73 40.10 28.39
1.80V 289.92 254.26 228.73 208.32 189.79 173.49 160.06 141.11 107.51 86.85 64.53 39.60 28.26
1.85V 260.78 231.89 207.15 190.00 175.90 160.79 148.34 129.89 99.42 81.62 61.34 38.26 27.62

CSB China Storage Battery UPS12240 UPS-12240  12 Volt 40WPC (Watts Per Cell) Battery CSB China Storage Battery UPS12240 UPS-12240  12 Volt 40WPC (Watts Per Cell) Battery CSB China Storage Battery UPS12240 UPS-12240  12 Volt 40WPC (Watts Per Cell) Battery CSB China Storage Battery UPS12240 UPS-12240  12 Volt 40WPC (Watts Per Cell) Battery CSB China Storage Battery UPS12240 UPS-12240  12 Volt 40WPC (Watts Per Cell) Battery

• UPS12240 • UPS123606 • UPS123607 • UPS12540 •

 

 

Home Batteries  UPS Technology Emergency Lighting Battery Chargers Factory Links Contact Us Buy Batteries Online

Power Factor Inc.

2526 Manana Dr – Suite 102 – Dallas – Texas – 75220

800-706-7009

 Our Goal, NO DISSATISFIED CUSTOMERS!

Since 1995

While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.