UPS6-620
UPS12-100
UPS12-100MR
UPS12-140
UPS12-150MR
MR12-150
UPS12-170
UPS12-200
UPS12-210MR
MR12-210
UPS12-270
UPS12-300MR
MR12-300
UPS12-310
UPS12-350MR
MR12-350
UPS12-370
MR12-400
UPS12-475
MR12-490
MR12-540

800-706-7009

  • .• UPS6-620 • UPS12-100 • UPS12-100MR • UPS12-140 • UPS12-150MR • MR12-150 • UPS12-170 • UPS12-200 • UPS12-210MR • MR12-210 • UPS12-270 • UPS12-300MR • MR12-300 • UPS12-310 • UPS12-350MR • MR12-350 • UPS12-370 • MR12-400 • UPS12-475 • MR12-490 • MR12-540 •

  • Dynasty C&D Battery Johnson Control UPS12-310 

    Dynasty C&D Battery UPS12-310 & UPS12-310FR have been replaced  by the UPS12-350MR

    Click here to purchase the replacement UPS12-350MR Battery from our online store at batteriesasap.com

    UPS12-310
    Valve Regulated Lead Acid Battery
    for UPS standby power applications
    12V 88 AH @ 20 hr rate,
    12V 330 watts/cell @ 15 min. rate


    UPS12-310
    Valve Regulated Lead Acid Battery
    for UPS standby power applications
    12V 88 AH @ 20 hr rate,
    12V 330 watts/cell @ 15 min. rate

    FEATURES

    • Flame-arresting one-way pressure-relief vent for safety and long life.
    • Thermally welded case-to-cover bond to eliminate leakage.
    • Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99% and freedom from electrolyte maintenance.
    • Computer-generated grid design optimized for high power density.
    • UL-recognized component.
    • Multicell design for economy of installation and maintenance.
    • Can be mounted in any orientation.
    • Not restricted for air transport – Complies with IATA/ICAO Special Provision A67.
    • Not restricted for surface transport – Classified as non-hazardous material as related to DOT-CFR Title 49 parts 171-189.
    • Computer designed lead, low calcium alloy grid for minimal gassing and ease of recycling.
    • Case and cover available in both standard and flame retardant polypropylene.
    • Flame retardant polypropylene case and cover compliant with UL 1778 (optional).




     
    *All dimensions in inches and (millimeters). all dimensions are for reference only. Contact a C&D Representative for complete dimensional  information.


     

    UPS12-310 - Specifications
    Cells
    Per Unit
    Voltage
    Per Unit
    Weight
    Electrolyte
    Maximum
    Discharge Current
    Short Circuit Current
    Ohms Imped.
    60 Hz
    6
    12.84
    67 lbs.
    30 kg .
    Absorbed H2SO4
    SG = 1.300
    800 Amps
    4200 Amps
    @ 0.1 sec.
    0.0030 Ohms
    Capacity

     
    330 watts per cell at the 15 minute rate to 1.67 volts per cell at 77°F (25°C).
    88 Ah @ 20 hr. rate to 1.75 volts per cell @ 77°F (25°C).
    76 Ah @ 10 hr. rate to 1.80 volts per cell @ 20°C (68°F).
    Operating Temperature Range Discharge; -40°F (-40°C) to +160°F (71°C) Charge; -10°F (-23°C) to +140°F (60°C).
    (with temperature compensation)
    Nominal Operating Temperature Range
     
    +74°F (23°C) to +80°F (27°C).
    Float Charging Voltage
     
    13.5 to 13.8 VDC/unit Average at 77°F (25°C).
    Recommended Maximum Charging Current Limit
     
    C/5 amperes (17.6 amperes @ 100% depth of discharge) @ 20 hour rate.
    Equalization and Cycle Service Charging Voltage 14.4 to 14.8 VDC/unit Average at 77°F (25°C).
    Maximum AC Ripple (Charger) 0.5% RMS or 1.5% P-P of float charge voltage recommended for best results.
    Maximum voltage allowed = 1.4% RMS (4% P-P).
    Maximum current allowed = 4.4 amperes RMS (C/20).
    Self Discharge Dynasty UPS batteries may be stored for up to 6 months at 77°F (25°C) and then a freshening charge is required. For higher temperatures the time interval will be shorter.
    Accessories
     
    Inter unit connectors, racks and cabinet systems are available.
    Terminal
     
    "L" terminal with 0.28" clearance hole to accept 0.25" (6mm) bolt.
    Terminal Hardware Initial Torque
     
    65 in.-lbs. (7.4 N-m).
    Terminal Hardware Annual Retorque 52 in.-lbs. (5.88 N-m).


     





     
    Note: Batteries to be mounted with 0.5 in (1.25 cm) spacing minimum and free air ventilation. Specifications subject to change without notification.

     

    Dynasty C&D Battery UPS12-310 & UPS12-310FR

    Call for pricing

    • UPS6-620 • UPS12-100 • UPS12-100MR • UPS12-140 • UPS12-150MR • MR12-150 • UPS12-170 • UPS12-200 • UPS12-210MR • MR12-210 • UPS12-270 • UPS12-300MR • MR12-300 • UPS12-310 • UPS12-350MR • MR12-350 • UPS12-370 • MR12-400 • UPS12-475 • MR12-490 • MR12-540 •

     

     

    Home Batteries  UPS Technology Emergency Lighting Battery Chargers Factory Links Contact Us Buy Batteries Online

    Power Factor Inc.

    2526 Manana Dr – Suite 102 – Dallas – Texas – 75220

    800-706-7009

     Our Goal, NO DISSATISFIED CUSTOMERS!

    Since 1995

    While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
    All names referred to are trademarks or registered trademarks of their respective owners.