Up Next Home Batteries  UPS Technology Emergency Lighting Battery Chargers Factory Links Contact Us Buy Batteries Online

Established 1996                              Call us 800-706-7009

.
• Home • High Rate VRLA • PL Series • PM Series • Mobility Series • Broadband GEL • Traffic Grid Series • Solar Series • High Temperature Series • Telecom Products • Nickel Cadmium Batteries • Marine RV Series • TS Flooded Stationary Series • Flooded Deep Cycle Series • AG Sealed Deep Cycle Series • Cabinets / Racks •

.

 

Click here to Buy batteries online

Batteries
Eaton Showcase
UPS Technology
Emergency Lighting
Battery Chargers
TVSS
9 Power Problems
Olight Flashlights
Problems with Power
Factory Links
Contact Us

Telecom VRLA
Telecom Front Terminal Batteries
Coleman Global Telecommunication

800-706-7009

 

A+ Rating with the Better Business Bureau

Home Up Telecom VRLA Telecom Front Terminal Batteries Coleman Global Telecommunication

Telecom VRLA

The Power "TL and Front Access CSL" batteries are the ideal choice for Telecommunication applications which require a reliable, compact and affordable solution.

Our state of the art V.R.L.A. design utilizes an absorbed glass mat (A.G.M) separator technology to immobilize the battery electrolyte.

There is never any need to add water to the cells and in fact all vents are factory sealed. Since these batteries are low-gassing they require no special ventilation. Additionally, a compact design makes them perfect for low maintenance and space restricted applications.

Features

  • Ten year design life.
  • A recognized component of U.L.
  • Non-spillable valve regulated lead acid (VRLA) design.
  • Advanced absorbed glass mat technology (AGM) with gas recombination greater than 99%.
  • Operates at a low internal pressure.
  • Never needs watering, minimal maintenance.
  • 99.985% pure lead calcium grids.
  • Shock absorbent thick wall polypropylene cases.
  • Cases are flame retardant, meet U.L. 94. V0 requirements, and have an oxygen index greater than 28%.
  • Cold forged non-porous terminal bushings, eliminate post leakage.
  • Front access copper insert terminal.
  • Thermally welded cover to case bond, eliminates both acid and electrical leaks.
  • Over-sized, through the partition inter-cell welds provide low resistance connections with minimal power loss.
  • Each cell has a low pressure safety release venting system recognized per U.L. 924.
  • Measured high vacuum acid fill reduces electrical variability between cells.
  • 100% recyclable materials, MSDS.

Options

  • Terminal covers and custom inter-connecting battery cables. (Terminal covers are unit connectors standard on the CSL models).
  • SLC is available in all models.

Specifications

Operating temperature range: -40°C/-40°F to 60°C/140°F
Charging voltage / current: 2.27 to 2.30 volts per cell, constant voltage at a maximum current of C/4 amps.
Temperature compensation: Apply for temperature range of 0°C/32°F to 40°C/104°F. Subtract 3 mV/°C/cell or 1.7 mV/°F/cell, above 25°C/77°F. Add 3 mV/°C/cell or 1.7 mV/°F/cell, below 25°C/77°F.
Storage time from a fully charged condition: 6 months at 25°C/77°F. For each 9°C/15°F rise, reduce the storage time by half.


Download the Brochure in PDF format

General Specifications

Top Terminal

                Power Telecom TL Series

Battery Model Number

Rating

Physical Specifications

Terminal Type

Volts Nominal

AH @ 8 Hrs to 1.75 VPC

Dimension inch/mm

Weight

L

W

H

Lbs/Kg

TL-1230

12

29

7.7 / 196

5.2 / 132

7.2 / 183

26.7 / 12.0

Lead “L”

TL-1250

12

51

9 / 229

5.4 / 137

8.5 / 216

44.1 / 20.0

Copper insert

TL-1270

12

68

10.2 / 259

6.7 / 169

9.0 / 229

60.6 / 27.5

Copper insert

TL-1280

12

82

12.0 / 305

6.7 / 169

9.1 / 231

71.9 / 32.7

Copper insert

TL-1295

12

96

13.5 / 343

6.8 / 173

8.5 / 215

80.6 / 36.7

Copper insert

TL-12120

12

118

13.5 / 343

6.8 / 173

10.8 / 273

99.4 / 45.2

Copper insert

TL-6195

6

193

10.7 / 272

7.4 / 187

10.9 / 279

81.5 / 37.0

Copper Insert

Front Terminal

The CSL Front Terminal Series has been superceded to the FT Series, Click here to be directed to the FT Series.
   

Battery Model Number

Rating

Physical Spec.

Terminal type

Notes

Volt

AH @ 8 Hrs to 1.75 VPC

Dimension inch/mm

Weight

L

W

H

Lbs/Kg

CSL-1280

12

82

Superceded to FT-1290

CSL-12100

12

100

Superceded to FT-12100

CSL-12170

12

170

Superceded to FT-12170

CSL-12200

12

200

Superceded to FT-12200


 


 
  • Also available with wire harness and connector, specify models TL-1230SLC, TL-1250SLC and TL-1280SLC.
  • Cases are designed to accept a handle. (Optional)

No transport restrictions

  • Surface Transport.  Classified as non-hazardous material as relates to DOT-CFR Title 49 part 171-189
  • Marine transport.  Classified as non-hazardous material as per IMDG amendment 27
  • Air transport.  Complies with IATA / ICAO, special provision A67.

 

  

 

 

Home Batteries  UPS Technology Emergency Lighting Battery Chargers Factory Links Contact Us Buy Batteries Online

Power Factor Inc.

2526 Manana Dr – Suite 102 – Dallas – Texas – 75220

800-706-7009

 Our Goal, NO DISSATISFIED CUSTOMERS!

Since 1995

While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.