Home • Up • GP613 • GP633 • GP640 • GP645 • GP670 • GP690 • GP6110 • GP1213 • GP1222 • GP1245 • GP1270 • GP12110 • GP12170 • GP12200 • GP12260 • GP12340 • GP12400 • GP24150 • GP24170 • GP12650 • GP121000 • EVX1272 • EVX12120 • EVX12170 • EVX12200 • EVX12260 • EVX12300 • EVX12340 • EVX12400 • EVX12520 • EVX12650 • EVX12750 • EVX121000 • HC1217W • HC1221W • HC1225W • HC1228W • HR1221W • HR1224W • HR1234W • HR1251W • HR1290W • HR12120W

 

 

Contact Us Toll Free

Buy batteries on-line

Request Info

UPS Systems

Universal Battery Valve Regulated Lead Acid Batteries Batteries

  Emergency Lighting

Battery chargers, rectifiers, dc power systems by SENS Battery Chargers

Click for more about the Battery Rack™ 20 with Tester (Grey) Battery Storage

Specials!

Service

Lease Info

 

 

CSB China Storage Battery GP12200 GP-12200 12 Volt 20 Amp Hr. ( AH ) Battery  

GP12200

12 V 20.0Ah
GP 12200 is a general purpose battery up to 5 years in standby service or more than 260 cycles at 100% discharge in cycle service.
As with all CSB batteries, all are rechargeable, highly efficient, leak proof and maintenance free.
 
Download : GP12200 Spec Sheet-(694.23K)
 

 

Specification  
Cells Per Unit 6
Voltage Per Unit 12 V
Capacity 20Ah @ 20hr-rate to 1.75V per cell @ 25°C (77°F)
Weight (kg) Approx. 6.4kg. (14.1 lbs.)
Maximum Discharge current (A) 230A (5sec.)
Internal Resistance Approx. Approx. 13mΩ
Operating Temperature Range Discharge:-15℃~50℃(5°F~122°F)
Charge:-15℃~40℃(5°F~104°F)
Storage:-15℃~40℃(5°F~104°F)
Nominal Operating Temperature Range 25°C ± 3°C (77°F± 5°F)
Float charging voltage 13.5 to 13.8 VDC/unit Average at 25°C (77°F)
Recommended Maximum Charging current limit 6.0A
Equalization and Cycle Service 14.4 to 15.0 VDC/unit Average at 25°C (77°F)
Self Discharge CSB Batteries can be stored for more than 6 months at 25°C (77°F)Please charge batteries before using. For higher temperatures the time interval will be shorter.
Terminal I1-Thread lead alloy recessed terminal to accept M5 bolt
Container Material ABS(UL94-HB/File E50263)*Flammability resistance of(UL94-V0/File E88637) can be available upon request.


 

Dimensions  



 

Constant Current Discharge Characteristics Unit:Amperes (25℃,77℉)
F.V/Time 5MIN 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V 87.50 55.50 42.25 25.50 15.08 8.75 6.23 4.92 3.97 2.62 2.10 1.09
1.67V 77.70 51.76 39.70 24.90 15.02 8.69 6.22 4.90 3.94 2.60 2.07 1.04
1.70V 73.50 50.17 38.70 24.66 14.90 8.67 6.20 4.88 3.93 2.60 2.05 1.03
1.75V 66.41 46.96 37.12 24.17 14.75 8.54 6.17 4.86 3.92 2.59 2.03 1.00
1.80V 59.33 43.75 35.23 23.75 14.50 8.42 6.12 4.83 3.91 2.58 2.00 0.96
1.85V 52.24 40.54 33.65 23.16 14.25 8.29 6.07 4.79 3.90 2.57 1.96 0.92
Constant Power Discharge Characteristics Unit:Watts (25℃,77℉)
F.V/Time 5MIN 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V 1050.00 666.00 507.00 306.00 181.00 105.00 74.70 59.00 47.60 31.40 25.20 13.10
1.67V 932.40 621.20 481.10 301.10 178.90 104.30 74.63 58.93 47.32 31.26 24.92 12.54
1.70V 882.00 602.00 466.00 299.00 177.80 103.00 74.30 58.70 47.20 31.20 24.80 12.30
1.75V 797.00 563.50 445.50 292.00 175.80 102.00 74.00 58.45 47.05 31.10 24.40 11.90
1.80V 712.00 525.00 421.00 285.00 173.50 101.00 73.40 58.00 46.90 31.00 24.00 11.50
1.85V 627.00 486.50 403.64 278.00 171.00 99.50 72.80 57.55 46.75 30.90 23.60 11.10

Home - 9 Power Problems - Problems with Power - APC - Powerware - MinuteMan - MGE - Liebert - Batteries - Chargers / Rectifiers - Emergency Lighting - Service - Factory Links

 Contact Us

Power Factor Inc.

2526 Manana Dr – Suite 102 – Dallas – Texas – 75220

NO DISSATISFIED CUSTOMERS!

Since 1995

While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.