Home • Up • GP613 • GP633 • GP640 • GP645 • GP670 • GP690 • GP6110 • GP1213 • GP1222 • GP1245 • GP1270 • GP12110 • GP12170 • GP12200 • GP12260 • GP12340 • GP12400 • GP24150 • GP24170 • GP12650 • GP121000 • EVX1272 • EVX12120 • EVX12170 • EVX12200 • EVX12260 • EVX12300 • EVX12340 • EVX12400 • EVX12520 • EVX12650 • EVX12750 • EVX121000 • HC1217W • HC1221W • HC1225W • HC1228W • HR1221W • HR1224W • HR1234W • HR1251W • HR1290W • HR12120W

 

 

Contact Us Toll Free

Buy batteries on-line

Request Info

UPS Systems

Universal Battery Valve Regulated Lead Acid Batteries Batteries

  Emergency Lighting

Battery chargers, rectifiers, dc power systems by SENS Battery Chargers

Click for more about the Battery Rack™ 20 with Tester (Grey) Battery Storage

Specials!

Service

Lease Info

 

CSB China Storage Battery EVX12520 EVX-12520  12 Volt 52 Amp Hr. ( AH ) Battery

EVX Series
EVX12520
12 V 52.0Ah
EVX-12520 is designed specially for electric vehicles, such as electric golf cart, electric wheelchair, mower, dust collector etc. It has high cycling life, high efficiency and long service life.
 
Download : EVX12520 Spec Sheet-(652.53K)
 
Specification  
Cells Per Unit 6
Voltage Per Unit 12 V
Capacity 52 Ah @ 20hr-rate to 1.75V per cell @ 25°C (77°F)
Weight Approx. 18.3 kg. (40.35 lbs.)
Maximum Discharge Current 500A (5 sec)
Internal Resistance Approx. Approx. 6 mΩ
Operating Temperature Range Discharge:-15℃~50℃(5°F~122°F)
Charge:-15℃~40℃(5°F~104°F)
Storage:-15℃~40℃(5°F~104°F)
Nominal Operating Temperature Range 25°C ± 3°C (77°F ± 5°F)
Float Charging Voltage 13.5 to 13.8 VDC/unit Average at 25°C (77°F)
Recommended Maximum Charging current limit 15.6A
Equalization and Cycle Service 14.4 to 15.0 VDC/unit Average at 25°C (77°F)
Self Discharge CSB Batteries can be stored for more than 6 months at 25°C (77°F) Please charge batteries before using. For higher temperatures the time interval will be shorter.
Terminal B4-L terminal to accept M6 nut & bolt
Container Material Polypropylene(UL 94-V0/File E50955)*Flammability resistance of (UL 94-HB/File E216959) can be available upon request.


 

Dimensions  



 

Constant Current Discharge Characteristics Unit:Amperes (25℃,77℉)
F.V/Time 30MIN 60MIN 90MIN 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V 64.90 36.80 27.00 21.00 14.80 11.70 9.60 6.60 5.42 2.84
1.67V 63.50 36.36 26.82 20.80 14.64 11.60 9.52 6.52 5.36 2.80
1.70V 62.14 35.83 26.46 20.60 14.49 11.50 9.45 6.44 5.29 2.76
1.75V 60.60 35.20 26.05 20.30 14.33 11.40 9.36 6.34 5.21 2.72
1.80V 59.20 34.70 25.58 20.10 14.18 11.30 9.26 6.22 5.12 2.67
1.85V 57.80 34.20 25.07 19.90 14.05 11.20 9.15 6.11 5.03 2.62
Constant Power Discharge Characteristics Unit:Watts (25℃,77℉)
F.V/Time 30MIN 60MIN 90MIN 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V 668.00 386.00 283.79 221.00 154.00 124.00 102.09 70.90 58.70 33.60
1.67V 656.00 381.90 280.58 219.00 153.00 123.00 101.00 70.19 58.14 33.06
1.70V 645.00 377.60 277.18 217.00 152.23 122.00 100.10 69.42 57.44 32.47
1.75V 631.00 372.00 273.30 214.00 151.20 121.00 99.03 68.64 56.68 31.80
1.80V 615.00 368.00 269.00 212.00 150.00 120.00 98.06 67.60 55.80 31.12
1.85V 598.00 363.00 264.05 209.00 149.00 119.00 97.00 66.10 54.80 30.40

Home - 9 Power Problems - Problems with Power - APC - Powerware - MinuteMan - MGE - Liebert - Batteries - Chargers / Rectifiers - Emergency Lighting - Service - Factory Links

 Contact Us

Power Factor Inc.

2526 Manana Dr – Suite 102 – Dallas – Texas – 75220

NO DISSATISFIED CUSTOMERS!

Since 1995

While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.