Home • Up • GP613 • GP633 • GP640 • GP645 • GP670 • GP690 • GP6110 • GP1213 • GP1222 • GP1245 • GP1270 • GP12110 • GP12170 • GP12200 • GP12260 • GP12340 • GP12400 • GP24150 • GP24170 • GP12650 • GP121000 • EVX1272 • EVX12120 • EVX12170 • EVX12200 • EVX12260 • EVX12300 • EVX12340 • EVX12400 • EVX12520 • EVX12650 • EVX12750 • EVX121000 • HC1217W • HC1221W • HC1225W • HC1228W • HR1221W • HR1224W • HR1234W • HR1251W • HR1290W • HR12120W

 

 

Contact Us Toll Free

Buy batteries on-line

Request Info

UPS Systems

Universal Battery Valve Regulated Lead Acid Batteries Batteries

  Emergency Lighting

Battery chargers, rectifiers, dc power systems by SENS Battery Chargers

Click for more about the Battery Rack™ 20 with Tester (Grey) Battery Storage

Specials!

Service

Lease Info

 

CSB China Storage Battery EVX12120 EVX-12120  12 Volt 12 Amp Hr. ( AH ) Battery  

Click Here to Buy On-Line the EVX12120-F2

EVX Series
EVX12120
12 V 12.0Ah
EVX-12120 is designed specially for electric vehicles, such as electric golf cart, electric wheelchair, mower, dust collector etc. It has high cycling life, high efficiency and long service life.
 
Download : EVX12120 Spec Sheet-(636.68K)
 

 

Specification  
Cells Per Unit 6
Voltage Per Unit 12 V
Capacity 12 Ah @ 20hr-rate to 1.75V per cell @ 25°C(77°F)
Weight Approx. 3.83kg. (8.44 lbs.)
Maximum Discharge Current 150A/180A (5 sec)
Internal Resistance Approx. Approx. 18.5 mΩ
Operating Temperature Range Discharge:-15℃~50℃(5°F~122°F)
Charge:-15℃~40℃(5°F~104°F)
Storage:-15℃~40℃(5°F~104°F)
Nominal Operating Temperature Range 25°C ± 3°C (77°F ± 5°F)
Float Charging Voltage 13.5 to 13.8 VDC/unit Average at 25°C ( 77°F)
Recommended Maximum Charging current limit 3.6A
Equalization and Cycle Service 14.4 to 15.0 VDC/unit Average at 25°C (77°F)
Self Discharge CSB Batteries can be stored for more than 6 months at 25°C (77°F) Please charge batteries before using. For higher temperatures the time interval will be shorter.
Terminal F1/F2-Faston Tab187/250
Container Material ABS(UL94-HB/File E50263)*Flammability resistance of(UL94-V0/File E88637) can be available upon request.


 

Dimensions  



 

Constant Current Discharge Characteristics Unit:Amperes (25℃,77℉)
F.V/Time 30MIN 60MIN 90MIN 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V 10.58 6.74 4.93 3.95 2.89 2.29 1.88 1.30 1.08 0.65
1.67V 10.25 6.54 4.80 3.84 2.80 2.22 1.81 1.27 1.05 0.63
1.70V 9.92 6.33 4.63 3.74 2.72 2.16 1.77 1.23 1.03 0.61
1.75V 9.62 6.12 4.48 3.60 2.63 2.09 1.71 1.19 0.99 0.60
1.80V 9.33 5.92 4.33 3.49 2.54 2.02 1.65 1.16 0.96 0.58
1.85V 9.03 5.71 4.18 3.38 2.45 1.94 1.60 1.11 0.93 0.57
Constant Power Discharge Characteristics Unit:Watts (25℃,77℉)
F.V/Time 30MIN 60MIN 90MIN 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V 127.00 80.90 59.10 47.75 34.70 27.50 22.50 15.59 13.00 7.20
1.67V 123.10 78.60 57.50 46.02 33.63 26.68 21.83 15.20 12.62 6.93
1.70V 119.00 75.90 55.50 44.97 32.60 25.90 21.20 14.80 12.30 6.70
1.75V 115.50 73.45 53.70 43.45 31.55 25.05 20.50 14.35 11.90 6.50
1.80V 112.00 71.00 51.90 41.97 30.50 24.20 19.80 13.90 11.50 6.30
1.85V 108.50 68.55 50.10 40.45 29.45 23.35 19.23 13.45 11.10 6.10


 

Home - 9 Power Problems - Problems with Power - APC - Powerware - MinuteMan - MGE - Liebert - Batteries - Chargers / Rectifiers - Emergency Lighting - Service - Factory Links

 Contact Us

Power Factor Inc.

2526 Manana Dr – Suite 102 – Dallas – Texas – 75220

NO DISSATISFIED CUSTOMERS!

Since 1995

While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.