Home • Up • GP613 • GP633 • GP640 • GP645 • GP670 • GP690 • GP6110 • GP1213 • GP1222 • GP1245 • GP1270 • GP12110 • GP12170 • GP12200 • GP12260 • GP12340 • GP12400 • GP24150 • GP24170 • GP12650 • GP121000 • EVX1272 • EVX12120 • EVX12170 • EVX12200 • EVX12260 • EVX12300 • EVX12340 • EVX12400 • EVX12520 • EVX12650 • EVX12750 • EVX121000 • HC1217W • HC1221W • HC1225W • HC1228W • HR1221W • HR1224W • HR1234W • HR1251W • HR1290W • HR12120W

 

 

Contact Us Toll Free

Buy batteries on-line

Request Info

UPS Systems

Universal Battery Valve Regulated Lead Acid Batteries Batteries

  Emergency Lighting

Battery chargers, rectifiers, dc power systems by SENS Battery Chargers

Click for more about the Battery Rack™ 20 with Tester (Grey) Battery Storage

Specials!

Service

Lease Info

 

CSB China Storage Battery EVX121000 EVX-121000  12 Volt 100 Amp Hr. ( AH ) Battery

EVX Series
EVX121000
12 V 100.0Ah
EVX-121000 is designed specially for electric vehicles, such as electric golf cart, electric wheelchair, mower, dust collector…etc. It has high cycling life, high efficiency and long service life.
 
Download : EVX121000 Spec Sheet-(658.73K)
 

 

Specification  
Cells Per Unit 6
Voltage Per Unit 12 V
Capacity 100 Ah @ 20 Hr-Rate to 1.75V Per Cell @ 25℃(77℉)
Weight Approx. 35.5 Kg (78.26 lbs)
Maximum Discharge Current 500A (5 Sec)
Internal Resistance Approx. Approx. 8 mΩ
Operating Temperature Range Discharge:-15℃~50℃(5°F~122°F)
Charge:-15℃~40℃(5°F~104°F)
Storage:-15℃~40℃(5°F~104°F)
Nominal Operating Temperature Range 25℃±3℃(77℉±5℉)
Float Charging Voltage 13.5 to 13.8 VDC/Unit Average at 25℃(77℉)
Recommended Maximum Charging current limit 30 A
Equalization and Cycle Service 14.4 to 15.0 VDC/Unit Average at 25℃(77℉)
Self Discharge CSB Batteries can be stored for more than 6 months at 25℃(77℉). Please charge batteries before using. For higher temperatures the time interval will be shorter.
Terminal B4-L terminal to accept M6 nut & bolt
Container Material Polypropylene(UL 94-V0/File E50955)*Flammability resistance of (UL 94-HB/File E216959) can be available upon request.
Dimensions  



 

Constant Current Discharge Characteristics Unit:Amperes (25℃,77℉)
F.V/Time 30MIN 60MIN 90MIN 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V 75.67 52.25 38.90 30.91 23.12 19.00 16.15 11.42 9.67 5.48
1.67V 74.08 51.00 37.86 30.18 22.65 18.48 15.68 11.08 9.42 5.26
1.70V 72.23 49.67 36.80 29.49 22.15 17.90 15.18 10.75 9.17 5.17
1.75V 70.37 48.21 35.85 28.63 21.56 17.32 14.69 10.41 8.87 5.00
1.80V 68.33 46.75 34.90 27.87 20.84 16.75 14.11 10.08 8.58 4.84
1.85V 66.28 45.29 33.95 27.13 20.15 16.17 13.70 9.74 8.28 4.68
Constant Power Discharge Characteristics Unit:Watts (25℃,77℉)
F.V/Time 30MIN 60MIN 90MIN 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V 908.00 627.00 467.00 376.09 276.24 226.56 193.50 137.00 116.00 65.40
1.67V 889.00 612.00 454.00 367.80 269.10 221.40 189.80 133.00 113.20 63.40
1.70V 869.00 596.00 442.00 358.75 262.90 215.00 184.16 129.00 110.00 61.50
1.75V 844.50 578.50 430.50 349.22 255.85 208.00 178.03 125.00 106.50 59.60
1.80V 820.00 561.00 419.00 339.07 249.63 201.00 171.71 121.00 103.00 57.70
1.85V 795.50 543.50 407.50 329.30 242.94 195.70 166.76 117.00 99.50 55.80

Home - 9 Power Problems - Problems with Power - APC - Powerware - MinuteMan - MGE - Liebert - Batteries - Chargers / Rectifiers - Emergency Lighting - Service - Factory Links

 Contact Us

Power Factor Inc.

2526 Manana Dr – Suite 102 – Dallas – Texas – 75220

NO DISSATISFIED CUSTOMERS!

Since 1995

While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.