Back Up Next Home Batteries  UPS Technology Emergency Lighting Battery Chargers Factory Links Contact Us Buy Batteries Online

Established 1996                              Call us 800-706-7009

.
• Home • High Rate VRLA • PL Series • PM Series • Mobility Series • Broadband GEL • Traffic Grid Series • Solar Series • High Temperature Series • Telecom Products • Nickel Cadmium Batteries • Marine RV Series • TS Flooded Stationary Series • Flooded Deep Cycle Series • AG Sealed Deep Cycle Series • Cabinets / Racks •

.

 

Click here to Buy batteries online

Batteries
Eaton Showcase
UPS Technology
Emergency Lighting
Battery Chargers
TVSS
9 Power Problems
Olight Flashlights
Problems with Power
Factory Links
Contact Us

PSG Advanced Gel Series
Solar HPF
EZS Solar Systems
CZS Solar Systems
CRS Solar Systems
OCS Outdoor Systems
Power Ready IPS
CV Series
Solar Battery Rack Systems
Spill Containment

800-706-7009

 

A+ Rating with the Better Business Bureau

Home Up PSG Advanced Gel Series Solar HPF EZS Solar Systems CZS Solar Systems CRS Solar Systems OCS Outdoor Systems Power Ready IPS CV Series Solar Battery Rack Systems Spill Containment

CV Series 20yr VRLA

The most comprehensive range of VRLA battery systems designed for standby applications that require reliable power and long life.

Applications

  • Telecom, wired and wireless.
  • UPS.
  • Switchgear.
  • Renewable Energy.
  • Emergency Lighting.

Features

Design Life 20 years in float service at 77° F (25° C)
Patented catalyst in each cell Improves life by lowering float current, reducing grid corrosion and reducing water loss. It°s effects are even more apparent in higher temperatures.
Separators: Micro porous glass mat, H&V is standard.
Plate protection: Plate growth without damage is allowed by a collapsible bridge installed in the bottom of the container.
Electrolyte: Sulphuric acid solution, 1.300 s.g, when fully charged.
Float Voltage: 2.25 volts per cell at 77° F (25° C).
Self-discharge rate: 2% per month at 77° F (25° C).
Intercell connectors: Plated copper bussbars.
Internal air passages Aid heat dissipation, and ensure consistent cell temperatures.
Cell fronts Protected with a transparent, FR plastic cover.
Modules: Stackable to 8 high while certified to UBC seismic zone 4, Welded steel construction, Internal air passages aid heat dissipation, ensure consistent cell temperatures, Coated with an acid resistant powdered epoxy.

Specifications

Design Life 20 years in float service at 77° F (25° C).
Cell Type VRLA, with AGM method of electrolyte immobilization.
Grids Positive - proprietary, lead calcium Negative - lead calcium.
Container and cover impact resistant polypropylene with FR to UL 94 V0 optional.
Post Seals 2 part epoxy, 2 stage application
Jar to cover seal heat bonding method (Hardigg Machine).
Leak test method 100% of cells, with pressurized hydrogen
Safety Valve opens at 2.5 psi, closes at 2 psi, with flame arrestor in each valve. The Bunsen design is used.

Download the Brochure in PDF format

General Specifications

384CV525FR Space Saving Installation

 

 

 

Battery Systems Include:

  • Cells
  • Modules
  • Connectors
  • Mounting Base
  • Module Covers
  • Terminal Assembly
  • Lifting Strap
  • No Oxide Grease
  • Cell Numbers
  • Layout Drawing/BOM
  • Operating Manual
  • Modules are shipped 4 per pallet, with connectors and accessories on top of the pallets

Cell Details

  1. Container, high impact polypropylene, FR optional
  2. Cover, high impact polypropylene, FR optional
  3. Thermal welded container-to-cover seal
  4. Positive post, sealed with epoxy
  5. Negative post, sealed with epoxy
  6. Catalyst valve
  7. Negative plate, lead calcium grid alloy
  8. Separator , H&V AGM
  9. Positive plate, proprietary lead calcium
  10. Plate support, collapsible, 0.77 inches high

About the Catalyst Valve

  • Patented by Philadelphia Scientific

Effect on the cells/battery

  • Lowers the float current draw
  • Reduces the rate of positive grid corrosion
  • Converts gases created inside the cell back to water, thus enabling the recombination process to function at maximum efficiency
  • Prevents the negative plate from becoming discharged while on float charge thus maintaining full cell capacity
  • Greatly reduces the loss of water through the valve, preventing early failure from cell dryout
  • It will not allow excessive heat to build if the battery is charged at too high a rate. It will allow the gases to bypass the catalyst if the temperature reaches a set level
  • The catalyst active material will last the lifetime of the battery under normal operating conditions

Solid rack construction

The latest in production equipment is used for consitant reliability.

Post seals consistent of a two-stage application of epoxy.

Cells are given high rate and cycle tests in the labs, using large capacity equipment.

  • Battery Model: To designate the model of the battery system, specify the number of cells in the system, followed by the cell type: i.e. 24CV 1050 would be a 24 cell, 48 volt battery with a capacity of 1050 AH at the 8 hour rate 10 1.75 VPC.
  • ** Overall depth: The module depth includes the module cover. The overall depth including the base assembly is 24” / 610 mm.
  • *** Overall height: To determine total number of module heights, add the total number of module height plus 4” / 102 mm for the base assembly and 6” / 152.4 mm for the terminal assembly.

No transport restrictions

  • Surface Transport. Classified as non-hazardous material as relates to DOT-CFR Title 49 part 171-189
  • Marine transport. Classified as non-hazardous material as per IMDG amendment 27
  • Air transport. Complies with IATA / ICAO, special provision A67.
  

 

 

Home Batteries  UPS Technology Emergency Lighting Battery Chargers Factory Links Contact Us Buy Batteries Online

Power Factor Inc.

2526 Manana Dr – Suite 102 – Dallas – Texas – 75220

800-706-7009

 Our Goal, NO DISSATISFIED CUSTOMERS!

Since 1995

While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.