BAT-0007
BAT-0046
BAT-0050
BAT-0053
BAT-0058
BAT-0060
BAT-0063
BAT-0065
BAT-0072
BAT-0101
BAT-0103
BAT-0121
BAT-0122
BAT-0123
BAT-0301
BAT-0342
BAT-0370
BAT-0408
BAT-0481
BATA-012
BATA-041

800-706-7009

• BAT-0007 • BAT-0046 • BAT-0050 • BAT-0053 • BAT-0058 • BAT-0060 • BAT-0063 • BAT-0065 • BAT-0072 • BAT-0101 • BAT-0103 • BAT-0121 • BAT-0122 • BAT-0123 • BAT-0301 • BAT-0342 • BAT-0370 • BAT-0408 • BAT-0481 • BATA-012 • BATA-041 •

Eaton Powerware Best Power BAT-0122, BAT0122, BAT0-122 12 volt 88 Amp Hour (AH)  replacement battery 

Click Here to Buy On-Line


Valve Regulated Lead Acid Battery
for UPS standby power applications
12V 88 AH @ 20 hr rate,
12V 330 watts/cell @ 15 min. rate

FEATURES

  • Flame-arresting one-way pressure-relief vent for safety and long life.
  • Thermally welded case-to-cover bond to eliminate leakage.
  • Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99% and freedom from electrolyte maintenance.
  • Computer-generated grid design optimized for high power density.
  • UL-recognized component.
  • Multicell design for economy of installation and maintenance.
  • Can be mounted in any orientation.
  • Not restricted for air transport – Complies with IATA/ICAO Special Provision A67.
  • Not restricted for surface transport – Classified as non-hazardous material as related to DOT-CFR Title 49 parts 171-189.
  • Computer designed lead, low calcium alloy grid for minimal gassing and ease of recycling.
  • Case and cover available in both standard and flame retardant polypropylene.
  • Flame retardant polypropylene case and cover compliant with UL 1778 (optional).




 
*All dimensions in inches and (millimeters). all dimensions are for reference only.


 

Specifications
Cells
Per Unit
Voltage
Per Unit
Weight
Electrolyte
Maximum
Discharge Current
Short Circuit Current
Ohms Imped.
60 Hz
6
12.84
67 lbs.
30 kg .
Absorbed H2SO4
SG = 1.300
800 Amps
4200 Amps
@ 0.1 sec.
0.0030 Ohms
Capacity

 
330 watts per cell at the 15 minute rate to 1.67 volts per cell at 77°F (25°C).
88 Ah @ 20 hr. rate to 1.75 volts per cell @ 77°F (25°C).
76 Ah @ 10 hr. rate to 1.80 volts per cell @ 20°C (68°F).
Operating Temperature Range Discharge; -40°F (-40°C) to +160°F (71°C) Charge; -10°F (-23°C) to +140°F (60°C).
(with temperature compensation)
Nominal Operating Temperature Range
 
+74°F (23°C) to +80°F (27°C).
Float Charging Voltage
 
13.5 to 13.8 VDC/unit Average at 77°F (25°C).
Recommended Maximum Charging Current Limit
 
C/5 amperes (17.6 amperes @ 100% depth of discharge) @ 20 hour rate.
Equalization and Cycle Service Charging Voltage 14.4 to 14.8 VDC/unit Average at 77°F (25°C).
Maximum AC Ripple (Charger) 0.5% RMS or 1.5% P-P of float charge voltage recommended for best results.
Maximum voltage allowed = 1.4% RMS (4% P-P).
Maximum current allowed = 4.4 amperes RMS (C/20).
Self Discharge Dynasty UPS batteries may be stored for up to 6 months at 77°F (25°C) and then a freshening charge is required. For higher temperatures the time interval will be shorter.
Accessories
 
Inter unit connectors, racks and cabinet systems are available.
Terminal
 
"L" terminal with 0.28" clearance hole to accept 0.25" (6mm) bolt.
Terminal Hardware Initial Torque
 
65 in.-lbs. (7.4 N-m).
Terminal Hardware Annual Retorque 52 in.-lbs. (5.88 N-m).


 





 
Note: Batteries to be mounted with 0.5 in (1.25 cm) spacing minimum and free air ventilation. Specifications subject to change without notification.

Eaton Powerware Best Power BAT-0122, BAT0122, BAT0-122 12 volt 88 Amp Hour (AH)  replacement battery  Eaton Powerware Best Power BAT-0122, BAT0122, BAT0-122 12 volt 88 Amp Hour (AH)  replacement battery  Eaton Powerware Best Power BAT-0122, BAT0122, BAT0-122 12 volt 88 Amp Hour (AH)  replacement battery  Eaton Powerware Best Power BAT-0122, BAT0122, BAT0-122 12 volt 88 Amp Hour (AH)  replacement battery  Eaton Powerware Best Power BAT-0122, BAT0122, BAT0-122 12 volt 88 Amp Hour (AH)  replacement battery  Eaton Powerware Best Power BAT-0122, BAT0122, BAT0-122 12 volt 88 Amp Hour (AH)  replacement battery  Eaton Powerware Best Power BAT-0122, BAT0122, BAT0-122 12 volt 88 Amp Hour (AH)  replacement battery   

 • BAT-0007 • BAT-0046 • BAT-0050 • BAT-0053 • BAT-0058 • BAT-0060 • BAT-0063 • BAT-0065 • BAT-0072 • BAT-0101 • BAT-0103 • BAT-0121 • BAT-0122 • BAT-0123 • BAT-0301 • BAT-0342 • BAT-0370 • BAT-0408 • BAT-0481 • BATA-012 • BATA-041 •

 

 

 

Home Batteries  UPS Technology Emergency Lighting Battery Chargers Factory Links Contact Us Buy Batteries Online

Power Factor Inc.

2526 Manana Dr – Suite 102 – Dallas – Texas – 75220

800-706-7009

 Our Goal, NO DISSATISFIED CUSTOMERS!

Since 1995

While every precaution has been taken to ensure accuracy and completeness in this literature, Power Factor Inc. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.